Thermal Danger OK <<<<
I/O Configuration OK
Power OK
Device Failure OK
Device Degraded OK
Gathering failure information
To obtain information about failures recorded by the system, use the following commands:
•
Show cae –L
sd-oa1> show cae -L
Sl.No Severity EventId EventCategory PartitionId
EventTime Summary
###########################################################################
#####
71 Critical 3040 System Coo... N/A Fri May 18 06:26:34
2012 SXFM air intake
or exhaust temperature...
70 Critical 3040 System Coo... N/A Fri May 18 04:56:22
2012 SXFM air intake
or exhaust temperature...
•
show CAE –E -n
<SI.No>
Use
show CAE –E -n
<SI.No>
to obtain more details about specific events.
oa1> show cae -E -n 70
Alert Number : 70
Event Identification :
Event ID : 3040
Server blade appears non-functional
Provider Name : CPTIndicationProvider
Event Time : Fri May 18 04:56:22 2014
Indication Identifier : 8304020120518045622
Managed Entity :
OA Name : sd-oa1
System Type : 59
System Serial No. : USExxxxxS
OA IP Address : aa.bb.cc.dd
Affected Domain :
Enclosure Name : lc-sd2
RackName : sd2
RackUID : 02SGHxxxxAVY
Impacted Domain : Complex
Complex Name : SD2
Partition ID : Not Applicable
Summary :
XFM air intake or exhaust temperature is too hot
Full Description :
The air temperature measured at one of the XFM air intakes or exhausts is
too hot to allow
normal operation. Measures are being taken to increase the cooling
ability of the box, and
to reduce heat generation. If the temperature continues to increase,
however, partitions
might be shut down to prevent hardware damage.
48
Gathering failure information