Ethernet Teaming 165
Table 13-29
HP_AlterIndication: Network Interface Connectivity Lost
Property name
Property implementation
ProviderVersion
Provider version generating the indication in the form,
major.minor.revision.build
.
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication
SystemGUID
Platform GUID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemProductId
Product ID of the computer system generating the
indication
SystemSerialNumber
Serial number of the computer system generating the
indication
VariableName[0]
FailedMemberPath, implemented only if
AlertingManagedElement is an Ethernet Team.
VariableTypes[0]
1 (string), implemented only if
AlertingManagedElement is an Ethernet Team.
VariableValues[0]
WBEM path of the failed Ethernet Port,
HP_WinEthernetPort, implemented only if
AlertingManagedElement is an Ethernet Team.
•
3 (Enclosure) for c-Class blade systems
ImpactedDomain
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional
property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional
property containing the virtual system
UUID when running in a Virtual Connect environment.
13.4.6Network Interface Connectivity Restored
Table 13-30
HP_AlertIndication: Network Interface Connectivity Restored
Property name