HP Integrity BL860c Скачать руководство пользователя страница 103

 

 

 

PCI Device  103  

Table 8-3 

 Class: HP_PCIBridge

 

Property name 

Property implementation 

PCIDeviceID 

PCI device ID as described in the configuration 
registers for this PCI device 

RevisionID 

Revision ID as described in the configuration registers 
for this PCI device 

SubsystemID 

Subsystem ID as described in the configuration 

registers for this PCI device 

SubsystemVendorID 

Subsystem Vendor ID as described in the configuration 
registers for this PCI device 

VendorID 

Vendor ID as described in the configuration registers 

for this PCI device 

CIM_PCIBridge 

BridgeType 

Enumeration describing the type of PCI bridge. 

 

0: Host bridge 

 

1: ISA bridge 

 

2: EISA bridge 

 

3: MicroChannel bridge 

 

4: PCI-to-PCI bridge 

 

5: PCMCIA bridge 

 

6: NuBus bridge 

 

7: CardBus bridge 

 

8: RACEway bridge 

 

128: Other 

HP_PCIBridge 

 

8.3.3HP_PCICard 

HP_PCICard is used to represent physical PCI adapter card installed on Integrity servers. There is an 

instance of this class for each PCI adapter card present in the system. 

 

Table 8-4 

 Class: HP_PCICard

 

Property name 

Property Implemenation 

CIM_ManagedElement 

Caption 

A string describing the full location path of the  card. 
Examples: 

Slot 2 (

non-cellular systems) 

Cabinet 8 Bay 0 Chassis 1 Slot 2

 (cellular 

systems) 

CIM_ManagedSystemElement 

 

 

Содержание Integrity BL860c

Страница 1: ...HP Insight Management WBEM Providers for Windows on Integrity Servers Data Sheet Part number 5992 5647 Third Edition September 2009 ...

Страница 2: ...stituting an additional warranty HP will not be liable for technical or editorial errors or omissions contained herein Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial items are licensed to the U S Government under vendor s ...

Страница 3: ... CPU 31 3 1Overview 31 3 2Use cases 31 3 3Class implementations 31 3 3 1 HP_Processor 31 3 3 2 HP_ProcessorCapabilities 33 3 3 3 HP_ProcessorCore 34 3 3 4 HP_HardwareThread 36 3 3 5 HP_ProcessorCacheMemory 38 3 3 6 HP_SystemProcessor 40 3 3 7 HP_ProcessorElementCapabilities 41 3 3 8 HP_ProcessorCoreComponent 41 3 3 9 HP_HWThreadComponent 42 3 3 10 HP_AssociatedCacheMemory 42 3 3 11 HP_ProcessorCol...

Страница 4: ... use cases 63 5 3Class implementations 63 5 3 1 HP_Fan 63 5 3 2 HP_CoolingCollection 65 5 3 3 HP_CoolingRedundancySet 66 5 3 4 HP_MemberOfCoolingRedundancy 67 5 3 5 HP_HostedCoolingRedundancySet 68 5 3 6 HP_MemberOfCoolingCollection 68 5 3 7 HP_HostedCoolingCollection 68 5 3 8 HP_SystemFan 68 5 3 9 HP_FanModule 69 5 3 10 HP_FanSlot 70 5 3 11 HP_FanInSlot 71 5 3 12 HP_RealizesFan 71 5 3 13 HP_Syste...

Страница 5: ...oryModuleSlot 98 7 3 19 HP_SystemMemoryBoardSlot 98 7 4Supported indications 98 8 PCI Device 99 8 1Overview 99 8 2Use cases 99 8 3Class implementations 99 8 3 1 HP_PCIDevice 99 8 3 2 HP_PCIBridge 101 8 3 3 HP_PCICard 103 8 3 4 HP_PCISlot 105 8 3 5 HP_PCICardInSlot 107 8 3 6 HP_RealizesPCIDevice 108 8 3 7 HP_SystemPCISlot 108 8 3 8 HP_SystemPCIDevice 108 8 3 9 HP_Location 108 8 3 10 HP_ElementLocat...

Страница 6: ...35 12 3 5 HP_BladeEnclosureGroupHostedCollection 136 12 3 6 CIM_SoftwareIdentity 136 12 3 7 CIM_ElementSoftwareIdentity 137 12 3 8 CIM_InstalledSoftwareIdentity 138 12 3 9 HP_Location 138 12 3 10 HP_ElementLocation 139 12 4 Supported indications 139 13 Ethernet Teaming 140 13 1 Overview 140 13 2 Use cases 141 13 3 Class implementations 141 13 3 1 HP_EthernetPort 141 13 3 2 HP_EthernetDevice 143 13...

Страница 7: ... 4 13 Ethernet Team Active Member Count Change 179 13 4 14 Ethernet Provider Fatal Error 181 13 4 15 Ethernet Provider Cannot Access Data Source 183 14 Operating System Status 186 14 1 Overview 186 14 2 Use Cases 186 14 3 Class Implementations 186 14 3 1 HP_OperatingSystem 186 14 3 2 CIM_RunningOS 188 14 3 3 CIM_InstalledOS 188 14 4 Supported Indications 188 15 Smart Array 189 15 1 Overview 189 15...

Страница 8: ...ion 226 15 3 48 HPSA_ArraySystemSPIPort Association 226 15 3 49 HPSA_ArraySystemDAPort Association 226 15 3 50 HPSA_ArraySystemPrimordialPool Association 227 15 3 51 HPSA_ArraySystemStoragePool Association 227 15 3 52 HPSA_ComputerSystemArraySystem Association 227 15 3 53 HPSA_ArraySystemArrayController Association 227 15 3 54 HPSA_StorageEnclosureStorageEnclosureProcessor Association 228 15 3 55 ...

Страница 9: ...237 15 3 97 HPSA_ DiskDriveTSASSCSIProtocolEndpoint Association 238 15 3 98 HPSA_SCSIInitiatorTargetLogicalUnitPath 238 15 4 Supported indications 238 15 4 1 Physical Drive Status Changed to OK 238 15 4 2 Physical Drive Status Changed to ERROR 241 15 4 3 Physical Drive Status Changed to REBUILDING 243 15 4 4 Physical Drive Status Changed to PREDICTIVE FAILURE 245 15 4 5 Logical Drive Status Change...

Страница 10: ...4 16 3 19 HPFCHBA_SystemServiceAccessPoint 314 16 3 20 HPFCHBA_FCPortFCPortStatistics 315 16 3 21 HPFCHBA_FCPortLogicalPortGroup 315 16 3 22 HPFCHBA_FCPortSCSIProtocolEndpoint 315 16 3 23 HPFCHBA_SCSIProtocolControllerFCPort 316 16 3 24 HPFCHBA_PortControllerFCPort 316 16 3 25 HPFCHBA_PhysicalPackagePortController 316 16 3 26 HPFCHBA_SoftwareIdentityDrvPortController 317 16 3 27 HPFCHBA_PortContro...

Страница 11: ...olumeStorageSetting Association 349 17 3 36 HPSAS_PrimordialPoolStorageCapabilities Association 350 17 3 37 HPSAS_PrimordialPoolNoRaidStorageCapabilities Association 350 17 3 38 HPSAS_StoragePoolStorageCapabilities Association 350 17 3 39 HPSAS_ArraySystemSCSIProtocolController Association 350 17 3 40 HPSAS_ArraySystemPortController Association 351 17 3 41 HPSAS_ArraySystemDiskDrive Association 35...

Страница 12: ...Changed to Non Redundant 376 17 4 11 Enclosure Power Supply Status Changed to OK Redundant 378 17 4 12 Enclosure Power Supply Status Changed to Redundant Degraded 380 17 4 13 Enclosure Temperature Sensor Status Changed to OK 382 17 4 14 Enclosure Temperature Status Changed to Warning 384 17 4 15 Enclosure Temperature Sensor Status Changed to Critical 386 17 4 16 Enclosure Fan Status Changed to OK ...

Страница 13: ...ciation 418 18 3 45 HPSCSI_DiskPhysicalPackageDiskDrive Association 418 18 3 46 HPSCSI_StorageExtentStorageVolume Association 418 18 3 47 HPSCSI_DAPortSCSIProtocolEndpoint Association 418 18 3 48 HPSCSI_HBASCSIProtocolEndpointSPIPort Association 419 18 3 49 HPSCSI_HBAGroupCollectionComputerSystem Association 419 18 3 50 HPSCSI_HBAGroupCollectionHBAComputerSystem Association 419 18 3 51 HPSCSI_HBAS...

Страница 14: ...MITape_TapeDrive 471 21 3 2 HPWMITape_TapeDriveStatData 472 21 3 3 HPWMITape_TapeDriveMediaLocation 473 21 3 4 HPWMITape_PhysicalTape 474 21 3 5 HPWMITape_TapeDriveCapabilities 475 21 3 6 HPWMITape_TapeDriveEnclosure 475 21 3 7 HPWMITape_Product 476 21 3 8 HPWMITape_SCSIProtocolEndpoint 477 21 3 9 HPWMITape_TapeDriveFirmware 477 21 3 10 HPWMITape_TapeDriveSPIPort 478 21 3 11 HPWMITape_TapeDriveSAS...

Страница 15: ...leaning Required 500 21 4 12 Cleaning Tape Replacement Required 502 22 Host Discovered Resources HDR 504 22 1 Overview 504 22 2 Use Cases 504 22 3 Class implementations 504 22 3 1 HPHDR_ComputerSystem 504 22 3 2 HPHDR_SCSIProtocolEndPointInitiator 505 22 3 3 HPHDR_SCSIProtocolEndPointTarget 505 22 3 4 HPHDR_LogicalDisk 506 22 3 5 HPHDR_RemoteServiceAccessPoint 508 22 3 6 HPHDR_LogicalDiskRemoteSer...

Страница 16: ...anagement data through the Windows Management Instrumentation WMI framework for HP Integrity server platforms and options These providers implement the profiles and data described in this document Use of the providers requires Windows Server 2008 or Windows Server 2008 R2 and WMI ...

Страница 17: ...cal Asset profile P00114 DMTF Power State Management Profile DSP1027 and DMTF Software Inventory Profile DSP1023 2 3 Class implementations The following classes describe the base server implementation 2 3 1HP_WinComputerSystem HP_WinComputerSystem extends the class HP_ComputerSystem to model the base server Only one instance of HP_WinComputerSystem is instantiated on an Integrity server The follow...

Страница 18: ...tems that make up this computer system have an OperationalStatus value of Unknown One or more of the subsystems that make up this computer system have an OperationalStatus value of Other OK One or more of the subsystems that make up this computer system have an OperationalStatus value of Degraded One or more of the subsystems that make up this computer system have an OperationalStatus value of Err...

Страница 19: ... 3 CIM Tag Dedicated 0 Not Dedicated HP_ComputerSystem Name Computer system DNS name returned by Windows API GetComputerSystemName NameFormat DNSName PrimaryOwnerName Computer system primary owner name string initialized to not set writable property persistent across reboots PrimaryOwnerContact Computer system primary owner contact string initialized to not set writable property persistent across ...

Страница 20: ...an Integrity server The following properties are implemented Table 2 3 Class HP_ComputerSystemChassis Property name Property implementation CIM_PhysicalElement Tag Concatenation of serial number string and product ID string Model Serial Number CreationClassName HP_ComputerSystemChassis ElementName Computer system product name model string Manufacturer Computer manufacturer string Model Computer sy...

Страница 21: ...tem serial number string when running in a Virtual Connect environment If the system is not in a Virtual Connect environment there is no virtual Serial Number this property is not populated VirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment If the system is not in a Virtual Connect environment there is no virtual UUID this property is ...

Страница 22: ...erty name Property implementation CIM_ManagedElement Caption Server Power Management Service Description HP Integrity Server Power Management Service ElementName Server Power Management Service CIM_ManagedSystemElement OperationalStatus 2 OK StatusDescriptions StatusDescriptions 0 contains the following corresponding to OperationalStatus 0 Power Management Service is OK HealthState 5 OK CIM_Logica...

Страница 23: ...ation see the DMTF Power State Management Profile DSP01027 2 3 5HP_PowerManagementCapabilities HP_PowerManagementCapabilities extends the class CIM_PowerManagementCapabilities to model the server power management capabilities Only one instance of HP_PowerManagementCapabilities is instantiated on an Integrity server The following properties are implemented Table 2 7 Class HP_PowerManagementCapabili...

Страница 24: ...HP_AssociatedPowerManagementService is instantiated on an Integrity server The following properties are implemented Table 2 8 Class HP_AssociatedPowerManagementService Property name Property implementation CIM_ServiceAvailableToElement CIM_ AssociatedPowerManagementService PowerState 2 On RequestedState 12 Not Applicable HP_AssociatedPowerManagementService ServiceProvided ref HP_PowerManagementSer...

Страница 25: ...e instance Only one instance of HP_HostedPowerManagementService is instantiated on an Integrity server The following properties are implemented Table 2 10 Class HP_HostedPowerManagementService Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedService HP_HostedPowerManagementService Antecedent ref HP_ComputerSystem Dependent ref HP_PowerManagementService 2 3 9HP_Sy...

Страница 26: ...scription Location version n state Example System Firmware Version System Board version 009 016 000 Active ElementName family_code where family_code is the system ROM family code Example P31 For Integrity servers YYYY MM DD where YYYY is the four digit year of the release date MM is the two digit month of the release date and DD is the two digit day of the release date For Integrity servers this i...

Страница 27: ...e date and DD is the two digit day of the release date For Integrity servers this is a version string not a date For example 009 016 000 Manufacturer HP 11 Bios FCode Classifications 10 Firmware ClassificationDescriptions System ROM Firmware For Integrity servers Description Location Examples System Firmware Version System Board Management Processor Firmware Management Processor PDHC Firmware Vers...

Страница 28: ...the following if the Antecedent refers to an instance of a Redundant ROM ElementSoftwareStatus 0 6 Installed ElementSoftwareStatus 1 4 Fallback HP_SystemROMElementFirmwareIdentity Antecedent ref HP_SystemROMFirmware Dependent ref HP_ComputerSystem 2 3 11HP_SystemROMInstalledFirmwareIdentity HP_SystemROMInstalledFirmwareIdentity extends the class CIM_InstalledSoftwareIdentity and associates the HP_...

Страница 29: ...puterSystem Name HP_AlertIndication Summary WBEM Providers started EventCategory 1 Other ProbableCause 1 Other ProbableCauseDescription WBEM Providers Started ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of all IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows 2003 64 bit OSTy...

Страница 30: ...When ImpactedDomain is 3 Enclosure the following properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running ...

Страница 31: ...dll 3 2 Use cases For use cases see HP CPU Profile P00106 HP CPU Consolidated Status Profile P00107 HP CPU Physical Asset Profile P00108 and HP Location Profile P00124 3 3 Class implementations The following classes describe the CPU implementation 3 3 1HP_Processor HP_Processor extends the class CIM_Processor to model system processors The following properties are implemented Table 3 2 Class HP_Pr...

Страница 32: ...ular systems 0 Unknown OperationalStatus 0 2 OK when CPU is enabled and operational 2 OK when deconfigured by user from EFI 6 Error when disabled by firmware because of error 10 Stopped when deconfigured by user from EFI OperationalStatus 1 StatusDescriptions StatusDescriptions 0 text per OperationalStatus 0 Processor module status unknown Processor module status OK Processor module is degraded it...

Страница 33: ...IOS POST Error 7 Other Family Processor family number from SMBIOS for example 179 for Intel R Xeon TM and 130 for Itanium TM processor MaxClockSpeed Maximum clock speed in MHz for example 3600 CurrentClockSpeed Current clock speed in MHz for example 3066 DataWidth 64 x64 ia64 processors AddressWidth 64 x64 ia64 processors ExternalBusClockSpeed External bus clock speed in MHz for example 533 Charac...

Страница 34: ...4 for x64 processors Processor Capabilities IA64 for ia64 processors CIM_EnabledLogicalElementCapabilities ElementNameEditSupported 0 False RequestedStatesSupported None CIM_ProcessorCapabilities NumberOfProcessorCores Number of processor cores for example 1 2 NumberOfHardwareThreads Number of hardware threads for example 1 2 HP_ProcessorCapabilities 3 3 3HP_ProcessorCore HP_ProcessorCore extends ...

Страница 35: ...z Core m for cellular systems Socket z Core m for non cellular systems 0 Unknown OperationalStatus 0 2 OK when CPU is enabled and operational 2 OK when deconfigured by user from EFI 6 Error when deconfigured by firmware because of failure 10 Stopped when deconfigured by user from EFI OperationalStatus 1 StatusDescriptions StatusDescriptions 0 text per OperationalStatus 0 Processor module status un...

Страница 36: ...e Disabled by POST Error For x86 processors Characteristics Characteristics 0 3 32 bit Capable For x64 processors Characteristics 0 3 32 bit Capable Characteristics 1 2 64 bit Capable For ia64 processors Characteristics 0 2 64 bit Capable HP_ProcessorCore Bootstrap Not supported 3 3 4HP_HardwareThread HP_HardwareThread extends the class CIM_HardwareThread to model the hardware threads The followin...

Страница 37: ...or cellular systems Socket z Core m Thread n for non cellular systems 0 Unknown OperationalStatus 0 2 OK when CPU is enabled and operational 2 OK when deconfigured by user from EFI 6 Error when deconfigured by firmware because of failure 10 Stopped when deconfigured by user from EFI OperationalStatus 1 StatusDescriptions StatusDescriptions 0 text per OperationalStatus 0 Processor module status unk...

Страница 38: ...Thread n for non cellular systems HP_HardwareThread 3 3 5HP_ProcessorCacheMemory HP_ProcessorCacheMemory implements the class HP_CacheMemory which extends CIM_Memory to model the processor caches The following properties are implemented Table 3 6 Class HP_ProcessorcacheMemory Property name Property implementation CIM_ManagedElement Caption One of the following Level x Data Cache where x is the cac...

Страница 39: ...el number L3 CPU Cache Integrity servers Examples Level 1 Data Cache Level 2 Unified Cache Level 3 Cache CIM_ManagedSystemElement 0 Unknown OperationalStatus 0 2 OK when CPU is enabled and operational 2 OK when deconfigured by user from EFI 6 Error when by firmware because of failure 10 Stopped when deconfigured by user from EFI OperationalStatus 1 StatusDescriptions StatusDescriptions 0 text per ...

Страница 40: ...dows API GetComputerSystemName CreationClassName HP_ProcessorCacheMemory DeviceID One of the following Cabinet x Cell y Socket z Core m for cellular systems Socket z Core m for non cellular systems CIM_StorageExtent BlockSize 1024 number of bytes in a block NumberOfBlocks Number of blocks in this cache for example 8192 or 524288 Primordial 0 False CIM_Memory HP_CacheMemory HP_ProcessorCacheMemory ...

Страница 41: ... 3 8 Class HP_ProcessorElement Capabilities Property name Property implementation CIM_ElementCapabilities HP_ProcessorElementCapabilities ManagedElement ref HP_Processor Capabilities ref HP_ProcessorCapabilities 3 3 8HP_ProcessorCoreComponent HP_ProcessorCoreComponent extends the class CIM_ConcreteComponent and associates an HP_Processor instance with HP_ProcessorCore instances The following prope...

Страница 42: ...mory HP_AssociatedCacheMemory extends the class CIM_AssociatedCacheMemory The Integrity implementation class is HP_AssociatedProcessorCacheMemory HP_AssociatedProcessorCacheMemory associates an HP_Processor or an HP_ProcessorCore instance with an HP_CacheMemory instance The following properties are implemented Table 3 11 Class HP_AssociatedProcessorCacheMemory Property name Property implementation...

Страница 43: ...Memory 3 3 11HP_ProcessorCollection HP_ProcessorCollection extends the class HP_GroupSystemSpecificCollection The following properties are implemented Table 3 12 Class HP_ProcessorCollection Property name Property implementation CIM_ManagedElement Description A collection of processor packages with group aggregate status ElementName HP_ProcessorCollection CIM_Collection CIM_SystemSpecificCollectio...

Страница 44: ...ion HP_ProcessorGroupHostedCollection extends the class HP_GroupHostedCollection and associates the HP_ComputerSystem instance with the HP_ProcessorCollection instance The following properties are implemented Table 3 13 Class HP_ProcessorGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_ProcessorGroupHos...

Страница 45: ...agedSystemElement Cabinet x Cell y Socket z for cellular systems Name Socket z for non cellular systems 0 Unknown OperationalStatus 0 2 OK when CPU is enabled and operational 2 OK when deconfigured by user from EFI 6 Error when deconfigured by firmware because of failure 10 Stopped when deconfigured by user from EFI OperationalStatus 1 StatusDescriptions StatusDescriptions 0 text per OperationalSt...

Страница 46: ...z ia64 Processor Family 32 Model 1 Stepping 0 CreationClassName HP_ProcessorChip Cabinet x Cell y Socket z for cellular systems ElementName Socket z for non cellular systems Manufacturer Processor manufacturer string from SMBIOS for example Intel or AMD Model Model y where y is the processor model number Version Model y Stepping z where y is the processor model number and z is the processor steppi...

Страница 47: ...associates the HP_ComputerSystemChassis instance with HP_ProcessorChip instances The following properties are implemented Table 3 17 Class HP_SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor GroupComponent ref HP_ComputerSystemChassis PartComponent ref HP_ProcessorChip 3 3 17HP_ProcessorLocation HP_ProcessorLocation implements the...

Страница 48: ...ular systems CIM_Location Cabinet x Cell y Socket z for cellular systems Name Socket z for non cellular systems Cabinet x Cell y Socket z for cellular systems PhysicalPosition Socket z for non cellular systems HP_Location Cabinet x Cell y Socket z for cellular systems ElementLocationTag Socket z for non cellular systems ElementLocationTagDesc 14 Processor Module LocationInformation For non cellula...

Страница 49: ...ay contains the cabinet number LocationInfoDesc 2 10 Cell indicates that the third element of the LocationInformation array contains the cell number LocationInfoDesc 3 0 Slot indicates that the fourth element of the LocationInformation array contains the slot number HP_ProcessorLocation 3 3 18HP_ProcessorElementLocation HP_ProcessorElementLocation extends the class HP_ElementLocation and associate...

Страница 50: ...nstance mof HPWmiEvent mof HPWmiEvtCons mof HP_Sensor mof 4 2 Use cases For use cases see the HP Power Supply Profile P00103 and HP Power Supply Physical Asset Profile P00116 4 3 Class implementations Classes and properties are implemented as specified in the following tables for Integrity server platforms where available The following classes describe power supplies 4 3 1HP_PowerSupply HP_PowerSu...

Страница 51: ...mElement 2 OK if the power supply is operating properly OperationalStatus 0 6 Error if the power supply has failed Power Supply is operating properly if OperationalStatus 0 is 2 OK StatusDescriptions 0 Power Supply has failed if OperationalStatus is 6 Error 5 OK if the power supply is operating properly HealthState 20 Major Failure if the power supply has failed Name Power Supply n where n represe...

Страница 52: ...n systems modeling power supplies Table 4 3 Class HP_PowerCollection Property name Property implementation CIM_ManagedElement Caption Power Collection Description This is a collection of all devices including power supplies that provide power GroupStatusDescription GroupStatusDescription represents the value of the GroupStatusDescriptions 0 property ElementName Power Collection CIM_SystemSpecificC...

Страница 53: ...ration 6 Error If HP_WinPowerSupply OperationalStatus 0 for any non fault tolerant power supplies report 6 Error or if HP_WinPowerRedundancySet RedundancyStatus for any power redundancy sets report 5 Overall Failure Note If the system starts up with a redundancy status set to 4 Redundancy Lost and no power supplies have been removed or failed the GroupOperationalStatus is set to 2 OK because this ...

Страница 54: ...umberNeeded Not supported TypeOfSet 2 N 1 LoadBalanceAlgorithm 0 Unknown 0 Unknown if the redundancy status is unknown RedundancyStatus 2 Fully Redundant if the all power supplies in the set are operating properly and enough to achieve redundancy 3 Degraded Redundancy if there are at least enough power supplies for the redundancy set to provide power but power supplies have failed 4 Redundancy Los...

Страница 55: ...P_PowerRedundancySet 4 3 6HP_MemberOfPowerCollection HP_MemberOfPowerCollection is used to represent an association between HP_PowerSupply and HP_PowerCollection The Windows implementation class is HP_WinMemberOfPowerCollection Table 4 7 Class HP_MemberOfPowerCollection Property name Property implementation Collection References HP_PowerCollection Included Not supported Member References HP_PowerS...

Страница 56: ...name Property implementation CIM_ManagedElement Power Supply n Location where n represents the number of the power supply instance Caption Description Power Supply n Location provides power for system StatusDescription where n represents the number of the power supply instance and StatusDescription represents the value of StatusDescriptions 0 ElementName Power Supply n Location where n represents ...

Страница 57: ...ement Caption Power Supply n where n is the physical bay number CIM_ManagedSystemElement 0 Unknown Power supply unknown or not present HealthState 5 OK if power supply is operating properly 20 Major Failure if power supply has failed Name Power Supply n where n is the physical bay number 0 Unknown Power supply unknown or not present OperationalStatus 0 2 OK if power supply is operating properly or...

Страница 58: ...ns VendorCompatibilityStrings HPQ PowerSupply HP_PowerSupplySlot 4 3 11HP_PowerSupplyInSlot HP_PowerSupplyInSlot is used to represent an association between HP_PowerSupplyModule and HP_PowerSupplySlot that contains this Power Supply Table 4 12 Class HP_PowerSupplyInSlot Property name Property implementation Antecedent References HP_PowerSupplySlot Dependent References HP_PowerSupplyModule 4 3 12HP...

Страница 59: ...ved Table 4 15 Class HP_PowerMeter Property name Property implementation CIM_ManagedElement Caption Power Meter n where n represents the number of the power meter instance Description Power Meter n provides power monitoring for Power Suply m where n represents the number of the power meter instance and m represents the power supply instance ElementName Power Meter n where n represents the number o...

Страница 60: ... any of the following values PossibleStates 9 Normal CIM_NumericSensor CurrentReading Current reading of the power meter BaseUnits 7 Watts RateUnits 0 None UnitModifier 0 SupportedThresholds empty SettableThresholds empty HP_PowerMeter 4 3 15HP_AssociatedPowermeter HP_AssociatedPowerMeter extends the class CIM_AssociatedSensor and associates the HP_PowerMeter instance with the HP_PowerSupply insta...

Страница 61: ...on Name Power Supply n where n is a unique identifier for this power supply location instance PhysicalPosition PowerSupply n Location HP_Location ElementLocationTag Power Supply n Location ElementLocationTagDesc 0 HoodTag 4 3 17HP_ElementLocation HP_ElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement The Windows implementation class is HP_WinPowerSupplyE...

Страница 62: ...ity CIM_ConfigurationCapacity ObjectType 2 Power Supplies Increment 1 MaximumCapacity Maximum number of power supplies MinimumCapacity Not supported 4 3 19CIM_ElementCapacity CIM_ElementCapacity is used to represent an association between CIM_ConfigurationCapacity and the computer system chassis that contains this configuration capacity The Windows implementation class is HP_WinPowerSupplyElementC...

Страница 63: ...Cons mof HPErrorMetaInstance mof HPWmiEvent mof HPWmiEvtCons mof HP_Sensor mof 5 2 Table use cases For use cases see the HP Fan Profile P00102 and HP Fan Physical Asset Profile P00115 5 3 Class implementations Classes and properties are implemented as specified in the following tables for Integrity server platforms where available The following classes describe fans 5 3 1HP_Fan HP_Fan is used to m...

Страница 64: ...erating properly OperationalStatus 0 6 Error if fan has failed Fan is operating properly if OperationalStatus 0 is 2 OK StatusDescriptions 0 Fan has failed if OperationalStatus is 6 Error 5 OK if fan is operating properly HealthState 20 Major Failure if fan has failed Name Fan n where n represents the number of the fan instance CIM_LogicalDevice CreationClassName HP_WinFan DeviceID Fan n where n r...

Страница 65: ...ling fans Table 5 3 Class HP_CoolingCollection Property name Property implementation CIM_ManagedElement Caption Cooling Collection Description This is a collection of all devices including fans that provide cooling GroupStatusDescription where GroupStatusDescription represents the value of the GroupStatusDescriptions 0 property ElementName Cooling Collection CIM_SystemSpecificCollection InstanceID...

Страница 66: ...tus 0 for any non fault tolerant fans report 6 Error or HP_WinCoolingRedundancySet RedundancyStatus for any cooling redundancy sets report 5 Overall Failure Note If the system starts up with a redundancy status set to 4 Redundancy Lost and no fans have been removed or failed the GroupOperationalStatus is set to 2 OK because this is a valid configuration Unknown status for fans if GroupOperationalS...

Страница 67: ...Unknown 0 Unknown if the redundancy status is unknown RedundancyStatus 2 Fully Redundant if the all fans in the set are operating properly and enough to achieve redundancy 3 Degraded Redundancy if there are at least enough fans for the redundancy set to provide cooling but fans have failed 4 Redundancy Lost if there are not enough fans required to achieve redundancy but enough for the redundancy s...

Страница 68: ...ion Table 5 7 Class HP_MemberOfCoolingCollection Property name Property implementation Collection References HP_CoolingCollection Member References HP_Fan 5 3 7HP_HostedCoolingCollection HP_HostedCoolingCollection is used to represent an association between HP_CoolingCollection and the computer system that contains this collection The Windows implementation class is HP_WinHostedCoolingCollection T...

Страница 69: ...scription where n represents the number of the fan instance FanType represents the corresponding string value of the FanType enumeration and StatusDescription represents the value of StatusDescriptions 0 ElementName Fan n Location where n represents the number of the fan instance For example Fan 1 cabinet 0 blower 0 CIM_ManagedSystemElement 2 OK if fan is operating properly OperationalStatus 0 6 E...

Страница 70: ...ement 5 OK if fan is operating properly HealthState 20 Major Failure if fan has failed Name Fan n where n is the physical slot number 2 OK if fan is operating properly OperationalStatus 0 6 Error if fan has failed StatusDescription 0 Fan is operating properly if OperationalStatus 0 is 2 OK Fan has failed if OperationalStatus is 6 Error CIM_PhysicalElement CreationClassName HP_FanSlot Tag Fan n whe...

Страница 71: ...mplementation Antecedent References HP_FanSlot Dependent References HP_FanModule 5 3 12HP_RealizesFan HP_RealizesFan is used to represent an association between HP_Fan and HP_FanModule that realizes this fan Table 5 13 Class HP_RealizesFan Property name Property implementation Antecedent References HP_FanModule Dependent References HP_Fan 5 3 13HP_SystemPhysicalFan HP_SystemPhysicalFan is used to ...

Страница 72: ...em ElementName Fan n Location where n represents the fan position printed on the system labeling For example Fan 1 cabinet 0 blower 0 CIM_Location Name Fan n where n is the unique identifier for this fan location instance PhysicalPosition Fan n Location where n represents the number of the fan instance For example Fan 1 cabinet 0 blower 0 HP_Location ElementLocationTag Fan n Location where n repre...

Страница 73: ...on Fan Configuration Capacity Description This describes the number of fans that can be configured ElementName Fan Configuration Capacity CIM_PhysicalCapacity Name Unique identifier for this fan configuration capacity CIM_ConfigurationCapacity ObjectType 3 Fans Increment 1 MaximumCapacity Maximum number of fans MinimumCapacity Not supported 5 3 17CIM_ElementCapacity CIM_ElementCapacity is used to ...

Страница 74: ...System fan 74 5 4 Supported indications There are no indications specific to the system fan profile implementation ...

Страница 75: ...orMetaInstance mof HPWmiEvent mof HPWmiEvtCons mof 6 2 Use cases For use cases see the HP Sensor Profile 6 3 Class implementations The following classes and properties are implemented as specified in the following tables for Integrity server platforms The following classes describe temperature sensors 6 3 1HP_NumericSensor HP_NumericSensor is used to model temperature sensors on Integrity servers ...

Страница 76: ...utting down StatusDescriptions 0 Temperature reported by the sensor is within normal operating range if temperature reported by the sensor is within normal operating range Temperature reported by the sensor has exceeded its non critical threshold and the fans have been set to full speed if temperature reported by the sensor has exceeded its threshold and has set fans to full speed Temperature repo...

Страница 77: ...fully attempt to shutdown the system if the threshold is crossed SupportedThresholds 0 5 UpperThresholdFatal if the system will immediately power down the system if the threshold is crossed SettableThresholds empty UpperThresholdNonCritical Contains the threshold temperature that CurrentReading must exceed to be in a non critical state This is only set if the system will set fans to full speed if ...

Страница 78: ...ionalStatus 0 The most severe sensor group operational status 2 OK if temperatures reported by the sensors are within normal operating range 2 OK if temperatures reported by the sensors have exceeded its non critical threshold and has set fans to full speed 6 Error if temperatures reported by the sensors have exceeded its non critical threshold and the system is gracefully shutting down Temperatur...

Страница 79: ...r system that contains the collection The Windows implementation class is HP_Win HostedSensorCollection Table 6 5 Class HP_HostedSensorCollection Property name Property implementation Antecedent References HP_ComputerSystem Dependent References HP_SensorCollection 6 3 5HP_SystemSensor HP_SystemSensor is used to represent an association between HP_NumericSensor and the computer system that contains...

Страница 80: ...1 0 HP Location Profile 1 0 HPWmiMemory DLL Provider Installation Files HPWmiMemoryEvt DLL HPWmiMemoryEvtMsg DLL HPWmiMemory mof HPMemEvtCons mof HPErrorMetaInstance mof HPWmiEvent mof HPWmiEvtCons mof 7 2 Use cases For use cases see the HP memory profile 7 3 Class implementations The following classes are implemented for Integrity server platforms where available The following classes describe sy...

Страница 81: ...egraded when any physical memory module reports 3 Degraded This status does not represent the overall status of the memory system refer to the HP_MemoryCollection class for overall memory system status StatusDescriptions StatusDescriptions 0 contains descriptive text per OperationalStatus 0 System memory status OK System memory status Unknown System memory status Degraded 5 OK when OperationalStat...

Страница 82: ...s of the memory in kilobytes EndingAddress Ending address of the memory in kilobytes Volatile True HP_Memory HP_WinMemory 7 3 2HP_SystemMemory The class HP_SystemMemory represents an association between HP_WinMemory and the computer system that contains the memory The Windows implementation class is HP_WinSystemMemory There is one instance of this class Table 7 3 Class HP_SystemMemory Property nam...

Страница 83: ...ee the Memory Module Status StatusDescriptions 0 contains descriptive text per OperationalStatus 0 StatusDescriptions StatusDescriptions 1 contains descriptive text per OperationalStatus 1 For details see the Memory Module Status HealthState Enumerator indicating the memory module health state 0 Unknown when OperationalStatus 0 0 Unknown 5 OK when OperationalStatus 0 2 OK 10 Degraded Warning when ...

Страница 84: ...e This property is conditional It is populated if the data is available CIM_PhysicalComponent RemovalConditions 3 Removable when off CIM_Chip CIM_PhysicalMemory DataWidth Data width of memory module in bits InterleavePosition Not supported Capacity Total capacity of memory module in bytes TotalWidth Total width of memory module in bits Speed Not supported MemoryType Enumerator indicating the type ...

Страница 85: ...lots are not instantiated For cellular systems there is one HP_MemoryBoard instance for each cell board in the partition For non cellular systems with memory extenders there is one HP_MemoryBoard instance for each memory extender For non cellular systems without memory extenders there is one HP_MemoryBoard instance which represents the system board because the memory modules are housed on the syst...

Страница 86: ... x cellular systems where c is the cabinet number and x is the cell number One of the following Description System Board Extender x Cabinet x Cell y One of the following ElementName System Board Extender x Cabinet x Cell y CIM_PhysicalPackage RemovalConditions Removal conditions of the memory board When the memory board is the system board 2 Not applicable When the memory board is not the system b...

Страница 87: ...oard status OK not populated 3 Degraded 5 Predictive Failure Memory board contains a memory module that has correctable errors exceeding the condition for pre failure warranty Memory board status Degraded Memory board status Correctable error threshold for pre failure warranty has been exceeded 3 Degraded 3 Degraded Memory board has a configuration error for example there is a problem with the boa...

Страница 88: ...0 is determined by the worst of algorithm for physical memory boards and memory modules For details see the Memory Collection Status GroupStatusDescriptions GroupStatusDescriptions 0 contains descriptive text per GroupOperationalStatus 0 Memory collection status OK Memory collection status Degraded Memory collection status Unknown HP_MemoryCollection Table 7 9 Memory Collection Status RedundancySt...

Страница 89: ...pendency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_HostedMemoryCollection Antecedent ref HP_ComputerSystem Dependent ref HP_MemoryCollection 7 3 7HP_MemberOfMemoryCollection The class HP_ MemberOfMemoryCollection represents an association between HP_MemoryCollection and HP_MemoryModule or HP_MemoryBoard Table 7 11 Class HP_MemberOfMemoryCollection Property name Property...

Страница 90: ...erefore x consists of two numbers for example 0 1 indicates cab 0 cell 1 Table 7 13 Class HP_MemoryModuleSlot Property name Property implementation CIM_ManagedElement DIMM index Socket full location where full location includes the cabinet and cell for cellular systems and the extender board for systems that have memory extenders Caption CIM_ManagedSystemElement OperationalStatus OperationalStatus...

Страница 91: ...location includes the cabinet and cell for cellular systems and the extender board for systems that have memory extenders CIM_PhysicalConnector ConnectorLayout 1 Other ConnectorDescription DIMM index Socket full location where full location includes the cabinet and cell for cellular systems and the extender board for systems that have memory extenders CIM_Slot Number DIMM index HP_MemoryModuleSlot...

Страница 92: ... for non cellular systems where x is the board number HPQ HP_MemoryBoardSlot c x for cellular systems where c is the cabinet number and x is the cell Description A string describing the memory board physical location System Board Extender x Cabinet x Cell y ElementName A string describing the memory board physical location System Board Extender x Cabinet x Cell y CIM_PhysicalConnector ConnectorLay...

Страница 93: ...sociation between an HP_MemoryBoard and the HP_MemoryBoardSlot where it resides Table 7 16 Class HP_MemoryBoardInSlot Property name Property implementation CIM_Dependency CIM_PackageInConnector HP_MemoryBoardInSlot Antecedent ref HP_MemoryBoardSlot Dependent ref HP_MemoryBoard 7 3 13HP_ MemoryModuleSlotOnBoard The class HP_MemoryModuleSlotOnBoard represents an association between an HP_MemoryModul...

Страница 94: ... located x is the board number where the memory module is located y is the socket number where the memory module is located Description DIMM n Socket y or DIMM n Socket y Extender x for non cellular systems DIMM n Socket y Cabinet c Cell x for cellular systems Where n is the DIMM index c is the cabinet number where the memory module is located x is the board number where the memory module is locat...

Страница 95: ... is the socket number where the memory module is located HP_Location ElementLocationTag x y for non cellular systems c x y for cellular systems Where c is the cabinet number where the memory module is located x is the board number where the memory module is located y is the socket number where the memory module is located ElementLocationTagDesc 8 Memory Module LocationInformation 0 describes the m...

Страница 96: ...l location System Board Extender x Cabinet x Cell y ElementName A string describing the memory board physical location System Board Extender x Cabinet x Cell y CIM_Location Name A string describing the memory board physical location System Board Extender x Cabinet x Cell y PhysicalPosition One of the following x on non cellular systems where x is the board number c x on cellular systems where c is...

Страница 97: ...slot is occupied or not Table 7 20 Class HP_MemoryModuleSlotElementLocation Properties Property implementation CIM_ElementLocation HP_ElementLocation HP_MemoryModuleSlotElementLocation Element ref HP_MemoryModuleSlot PhysicalLocation ref HP_MemoryModuleSlotLocation 7 3 17HP_MemoryBoardSlotElementLocation The class HP_MemoryBoardSlotElementLocation extends the class HP_ElementLocation and is used t...

Страница 98: ...mMemoryModuleSlot GroupComponent ref HP_ComputerSystemChassis PartComponent ref HP_MemoryModuleSlot 7 3 19HP_SystemMemoryBoardSlot The class HP_SystemMemoryBoardSlot represents an association between HP_MemoryBoardSlot and HP_ComputerSystemChassis There is an instance of this class for each memory board slot in the chassis whether the slot is occupied or not Table 7 23 Class HP_SystemMemoryBoardSl...

Страница 99: ... following tables for Integrity server platforms where available The following classes describe PCI Device 8 3 1HP_PCIDevice HP_PCIDevice is used to model PCI devices on Integrity servers There is an instance of this class for each logical PCI device present in the system Table 8 2 Class HP_PCIDevice Property name Property implementation CIM_ManagedElement Caption A string describing the full loca...

Страница 100: ... The computer name as shown in Windows System Properties window Availability The primary availability and status of the Device 0 Reserved 1 Other 2 Unknown 3 Running Full Power 4 Warning 5 In Test 6 Not Applicable 7 Power Off 8 Off Line 9 Off Duty 10 Degraded 11 Not Installed 12 Install Error 13 Power Save Unknown 14 Power Save Low Power Mode 15 Power Save Standby 16 Power Cycle 17 Power Save Warn...

Страница 101: ...er The function number for this PCI device PCIDeviceID PCI device ID as described in the configuration registers for this PCI device RevisionID Revision ID as described in the configuration registers for this PCI device SubsystemID Subsystem ID as described in the configuration registers for this PCI device SubsystemVendorID Subsystem Vendor ID as described in the configuration registers for this ...

Страница 102: ...DeviceID A string containing bus dev fn For example BUS 135 DEV 1 FN 0 SystemCreationClassName HP_ComputerSystem CreationClassName SystemName HP_ComputerSystem Name CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_PCIController Capabilities 11 Provides slot identification CapabilityDescription String describing the full location ...

Страница 103: ...ers for this PCI device CIM_PCIBridge BridgeType Enumeration describing the type of PCI bridge 0 Host bridge 1 ISA bridge 2 EISA bridge 3 MicroChannel bridge 4 PCI to PCI bridge 5 PCMCIA bridge 6 NuBus bridge 7 CardBus bridge 8 RACEway bridge 128 Other HP_PCIBridge 8 3 3HP_PCICard HP_PCICard is used to represent physical PCI adapter card installed on Integrity servers There is an instance of this ...

Страница 104: ... A string describing the full location path of the card Examples Slot 2 non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems ElementName A string describing the full location path of the card Examples Slot 2 non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems CIM_PhysicalPackage RemovalConditions 2 Not Applicable PackageType 9 Module Card VendorCompatibilityStr...

Страница 105: ... the slot is empty this is indicated Caption Examples Slot 2 or Slot 3 Empty slot non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems CIM_ManagedSystemElement A string describing the full PCI slot location If the slot is empty this is indicated Name Examples Slot 2 or Slot 3 Empty slot non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems CIM_PhysicalElement Cre...

Страница 106: ...if slot is not powered Empty slots can be powered on or off but the API does not have a mechanism to determine the true state of empty slots Therefore by default empty slots are indicated as powered on CIM_PhysicalConnector 0 Unknown ConnectorLayout 1 Other 16 PCI 17 PCI X 18 PCI E if lane count is unknown otherwise use one of the following 19 PCI E x1 20 PCI E x2 21 PCI E x4 22 PCI E x8 23 PCI E ...

Страница 107: ...is 1 slot 2 SpecialPurpose Boolean to indicate if slot is embedded or not True embedded False not embedded PurposeDescription A free form string describing that this slot is physically unique and might hold special types of hardware This property only has meaning when the corresponding boolean property SpecialPurpose is set to TRUE If SpecialPurpose is set to 1 this string indicates this slot is e...

Страница 108: ...mPCISlot Property name Property implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_PCISlot 8 3 8HP_SystemPCIDevice HP_SystemPCIDevice is used to represent an association between HP_PCIDevice and the computer system that contains this PCI device Table 8 9 Class HP_SystemPCIDevice Property name Property implementation GroupComponent References HP_ComputerSy...

Страница 109: ...ar systems CIM_Location A string describing the full PCI slot location Examples Name Slot 2 non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems PhysicalPosition A string describing the full PCI slot location Examples Slot 2 non cellular systems Cabinet 8 Bay 0 Chassis 1 Slot 2 cellular systems HP_Location ElementLocationTag A string describing the full PCI slot location Examples...

Страница 110: ...ss HP_ElementLocation Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location 8 4 Supported indications There are no indications specific to the PCI device implementation ...

Страница 111: ... Profile 9 3 Class implementations The following classes are implemented for Integrity server platforms where available The following classes describe management processor systems and their relationship to the computer system on which they reside 9 3 1HP_ManagementProcessor HP_ManagementProcessor extends the class CIM_ComputerSystem and describes a management processor controller system The follow...

Страница 112: ...ic descriptions of when each value is populated OperationalStatus 0 contains MP operational status 0 Unknown when NICCondition 0 2 OK normal operation 3 Degraded when NICCondition 5 6 Error when NICCondition 6 or MP software interface fails OperationalStatus 1 contains NIC status when MP is enabled 0 Unknown when NICCondition 0 or MP software interface fails 2 OK normal operation 3 Degraded when N...

Страница 113: ...fails HealthState 5 OK normal operation 10 Degraded Warning when OperationalStatus 0 3 Degraded 20 Major failure when OperationalStatus 0 6 Error Note When a Management Processor is disabled refer to property EnabledState HealthState always reports a state of 5 OK so as not to contribute negatively to overall system status An MP is disabled only if the user has manually disabled it via the MP s RB...

Страница 114: ...known 1 Other 2 PCI Board Remote Insight Lights Out Edition II RILOE II 3 Embedded Integrated Lights Out Controller iLO 4 Embedded Integrated Lights Out Controller 2 iLO 2 5 Embedded Integrity Management Processor 6 Embedded Integrity Integrated Lights Out Controller iLO 7 Embedded Integrity Integrated Lights Out Controller 2 iLO 2 8 PCI Board Lights Out 100 Series LO 100 OtherControllerType Not s...

Страница 115: ...ler It is assumed that any protocol listed is active and can be utilized NICCondition Not Supported always 0 unknown ActiveLicense Not supported LicenseKey Not supported 9 3 2CIM_SoftwareIdentity CIM_SoftwareIdentity describes management processor firmware The Windows specific implementation class is HP_MPFirmware The following properties are implemented Table 9 3 Class CIM_SoftwareIdentity Proper...

Страница 116: ...ware component IsEntity FALSE The SoftwareIdentity instance does not correspond to a discrete copy of the Software MajorVersion Not supported MinorVersion Not supported VersionString String indicating the MP firmware version information This property is the string translation of the content provided in the MajorVersion and MinorVersion properties Manufacturer Hewlett Packard Classifications 10 Fir...

Страница 117: ...group operational status of the management processor collection refer to HP Management Processor MP Lite Profile The group operational status represents the worst of algorithm for all individual MP statuses in HP_ManagementProcessor OperationalStatus 0 GroupOperationalStatus 0 contains group operational status 0 Unknown 2 OK 3 Degraded 6 Error GroupStatusDescription GroupStatusDescriptions 0 text ...

Страница 118: ...ntation CIM_Component CIM_SystemComponent CIM_ComponentCS HP_MPComponentCS GroupComponent ref HP_ComputerSystem PartComponent ref HP_ManagementProcessor 9 3 6HP_MPMemberOfCollection HP_MPMemberOfCollection extends the class CIM_MemberOfCollection and associates a management processor to the collection to which it belongs The following properties are implemented Table 9 7 Class HP_MPMemberOfCollect...

Страница 119: ...ble UpgradeCondition 1 Other OtherUpgradeCondition Describes the upgrade condition when UpgradeCondition is set to 1 Other ElementSoftwareStatus 0 6 Installed ElementSoftwareStatus ElementSoftwareStatus 1 2 Current HP_MPElementFirmwareIdentity Antecedent ref HP_MPFirmware Dependent ref HP_ManagementProcessor 9 3 8CIM_InstalledSoftwareIdentity CIM_InstalledSoftwareIdentity associates a management p...

Страница 120: ...Management Processor Lite 120 9 4 Supported indications There are no indications specific to the management processor profile implementation ...

Страница 121: ...he following classes describe the IPMI SEL Record Log implementation 10 3 1HP_CommonRecordLog HP_CommonRecordLog extends the class CIM_ RecordLog to model the server management record log The IPMI SEL implementation class is HPQ_CommonRecordLog The following properties are implemented Table 10 2 Class HP_CommonRecordLog Properties Property name Property implementation CIM_ManagedElement Caption Co...

Страница 122: ...lStatus 0 2 OK HealthState 10 Degraded when OperationalStatus 0 3 Degraded 20 Major Failure when OperationalStatus 0 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 Enabled RequestedState 5 No Change EnabledDefault 2 Enabled CIM_Log MaxNumberOfRecords Maximum number of records in the IPMI SEL for this platform 0 indicates this is not supported Number of records in the SEL log H...

Страница 123: ...s HPQ_CommonLogEntry The following properties are implemented Table 10 4 Class HP_CommonLogEntry Property name Property implementation CIM_ManagedElement Caption SEL Log Event where is the RecordID property for this class Description SEL event description as per Integrity system event database ElementName EventType that corresponds to the indication this SEL event generates HP_HardwareEvent HP_Fir...

Страница 124: ...al IsEventLocal Indicates if an event affects the local partition 1 Yes 0 No IsEventRepaired Indicates if an event is already repaired 1 Yes 0 No IsEventRepairable Indicates if an event is repairable 1 Yes 0 No Init_yyyymmddHHMM Logged date and time Mod_yyyymmddHHMM When repaired the repaired date and time Otherwise the logged date and time EventCategory Indication type for this event This is cons...

Страница 125: ...from the Common Event Database RecordDataType 3 Delimited ReportingEntity The reporting source of the entity logging this event For example OS agent in cabinet 0 cell slot 0 RawData Raw SEL event as logged by the firmware 16 bytes if no timestamp entry else 32 bytes MajorClass 12 IPMI SEL MinorClass 2 None UpdateTimestamp IPMI SEL log event update time stamp last logged date and time OccurrenceCou...

Страница 126: ...Method Name Method Implementation Repair Refer to HP Record Log profile P00109 10 3 3HP_LogManagesRecord HP_ LogManagesRecord extends the class CIM_ LogManagesRecord and associates instances of HP_CommonRecordLog and HP_CommonLogEntry The IPMI SEL implementation class is HPQ_LogManagesRecord The following properties are implemented Table 10 6 Class HP_LogManagesRecord Property name Property implem...

Страница 127: ...plex wide IPMI System Event Log SEL events HP_UseOfLog Antecedent ref HP_CommonRecordLog Dependent ref HP_ComputerSystem 10 4Supported indications For a complete list of indications generated for IPMI SEL events on Integrity servers see the HP Insight WBEM Provider Events Reference Guide for HP Integrity WBEM Providers release 6 5 ...

Страница 128: ...TF Platform Watchdog profile 11 3Class Implementations The following classes describe the Watchdog implementation 11 3 1HP_WinPlatformWatchdogService HP_WinPlatformWatchdogService implements the class CIM_PlatformWatchdogService to model Automatic Server Recovery ASR functionality of Integrity servers The following properties are implemented Table 11 2 Class HP_WinPlatformWatchdogService Property ...

Страница 129: ...s StatusDescriptions 0 contains one of the following corresponding to OperationalStatus 0 Watchdog status OK Watchdog status degraded Watchdog status error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState The enabled state of ASR 2 Enabled 3 Disabled RequestedState 12 Not Applicable CIM_Service CreationClassName HP_WinPlatformWatchdogService Started The started st...

Страница 130: ...l be only one instance of the Windows specific implementation HP_WinHostedWatchdogService instantiated on a Integrity server The following properties are implemented Table 11 3 Class CIM_HostedService Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedService HP_WinHostedWatchdogService Antecedent ref HP_ComputerSystem Dependent ref HP_WinPlatformWatchdogService 11...

Страница 131: ...System class instance to the CIM_PlatformWatchdogService instance The Windows specific implementation is HP_WinWatchdogServiceAvailableToElement The following properties are implemented Table 11 5 Class CIM_ServiceAvailableToElement Property name Property implementation CIM_ServiceAffectsElement HP_WinWatchdogServiceAailableToElement ServiceProvided ref HP_WinPlatformWatchdogService UserOfService ...

Страница 132: ...stem and describe the blade system enclosure Onboard Administrator and association to the individual blade system 12 3 1HP_BladeEnclosureCS HP_BladeEnclosureCS extends the class HP_ComputerSystem and describes a blade computer system enclosure The following properties are implemented Table 12 2 Class HP_BladeEnclosureCS Property name Property implementation CIM_ManagedElement Caption If enclosure ...

Страница 133: ...ate 5 OK enclosure status OK 10 Degraded Warning enclosure status Degraded 20 Major Failure enclosure status Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 Not Applicable RequestedState 12 Not Applicable EnabledDefault 2 Enabled CIM_System CreationClassName HP_BladeEnclosureCS CIM_ComputerSystem Dedicated 2 Other OtherDedicatedDescriptions Modular IdentifyingDescriptions 0 HPQ M...

Страница 134: ...ing properties are implemented Table 12 3 Class HP_BladeEnclosureCollection Property name Property implementation CIM_ManagedElement Description A collection of server blade enclosures with group aggregate status ElementName Server Blade Enclosure Collection CIM_Collection CIM_SystemSpecificCollection InstanceID HPQ HP_BladeEnclosureCollection 001 HP_GroupSystemSpecificCollection Caption Server Bl...

Страница 135: ...omputer system instance The following properties are implemented Table 12 4 Class HP_BladeSystemComponent Property name Property implementation CIM_Component CIM_SystemComponent HP_BladeSystemComponent GroupComponent ref HP_ComputerSystem the blade enclosure computer system PartComponent ref HP_ComputerSystem the blade servers computer system 12 3 4HP_MemberOfBladeEnclosureCollection HP_MemberOfBl...

Страница 136: ...ef HP_BladeEnclosureCollection 12 3 6CIM_SoftwareIdentity CIM_SoftwareIdentity describes blade enclosure firmware The Windows specific implementation class is HP_BladeEnclosureFW The following table lists the properties implemented Table 12 7 Class CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement Caption Server Blade Enclosure Firmware Description HP Server Blade Enclo...

Страница 137: ...ported for Onboard Administrator Manufacturer Hewlett Packard Classifications 10 Firmware ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue An array in which first element contains the path of the target type or firmware family and the second element is HPQ OA IdentityInfoType CIM SoftwareFamily HP_BladeEnclosureFW 12 3 7CIM_ElementSoftwareIdentity CIM_ElementSoftware...

Страница 138: ... HP_BladeEnclosureInstalledFWIdentity System ref HP_BladeEnclosureCS InstalledSoftware ref HP_BladeEnclosureFW 12 3 9HP_Location HP_Location is used to model the server blade location within an enclosure The Windows specific implementation class is HP_BladeCSLocation Table 12 10 Class HP_Location Property name Property implementation CIM_ManagedElement Caption Rack abc UUID def Enclosure jkl Seria...

Страница 139: ...esc 0 14 Blade Bay 12 3 10HP_ElementLocation HP_ElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement The Windows specific implementation class is HP_BladeCSElementLocation Table 12 11 Class CIM_InstalledSoftwareIdentity Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location 12 4Supported indica...

Страница 140: ...WinEthIPHostedAccessPoint dll HPWinEthIPProtocolEndpoint dll HPWinEthLANEndpoint dll HPWinEthLANEndpointToStats dll HPWinEthLANHostedAccessPoint dll HPWinEthMemberOfCollection dll HPWinEthPortToLANEndpoint dll HPWinEthPortToStats dll HPWinEthPXEVersion dll HPWinEthPXEVersionToPort dll HPWinEthRedundancyMember dll HPWinEthRedundancySet dll HPWinEthRedundancySetToLANEndpoint dll HPWinIPBindsToEthLAN...

Страница 141: ...nEthRedundancySet mof HPWinEthRedundancySetToLANEndpoint mof HPWinIPBindsToEthLANEndpoint mof 13 2Use cases For use cases see the HP Ethernet Teaming Profile 13 3Class implementations The following classes are implemented for Integrity server platforms The following classes describe Ethernet Ports Ethernet Teams and Ethernet LAN Endpoints 13 3 1HP_EthernetPort HP_EthernetPort models Ethernet Ports...

Страница 142: ...2 Enabled Disabled ports are not modeled EnabledState 5 Not Applicable CIM_LogicalDevice Key CreationClassName HP_WinEthernetPort Key DeviceId System GUID for the port IdentifyingDescriptions IdentifyingDescriptions 0 Location IdentifyingDescriptions 1 Hardware location IdentifyingDescriptions 2 Spare part number OtherIdentifyingInfo 0 Location string Slot CBHSS Embedded Slot Hardware Location str...

Страница 143: ...emented for single port adapters CIM_EthernetPort HP_EthernetPort VirtualPortNumber Virtual port number for FlexNICs 13 3 2HP_EthernetDevice HP_EthernetDevice associates an Ethernet Port to the containing Computer System The Windows implementation class is HP_WinEthDevice Table 13 3 Class HP_EthernetDevice Property name Property implementation CIM_Component CIM_SystemComponent CIM_SystemDevice Key...

Страница 144: ...2 Fully Redundant RedundancyStatus 3 Degraded Redundancy 4 Redundancy Lost 5 Overall Failure 2 N 1 TypeOfSet 3 Load Balanced VendorIdentifyingInfo Identifying data for the RedundancySet HP_GroupRedundancySet 2 OK GroupOperationalStatus 3 Degraded 6 Error HP_EthernetTeam ActiveMaximumTransmissionUnit Current maximum transmission unit in bytes Speed The current bandwidth of the team in bits per seco...

Страница 145: ...rOfCollection Key Collection ref HP_EthernetTeam Key Member ref HP_EthernetPort HP_EthernetTeamMember 2 OK MemberOperationalStatus 3 Degraded 6 Error MemberStatusDescriptions See the HP Ethernet Teaming Profile Example Degraded Fast Path 0 Unknown Role 1 None 1000 Tx Rx Transmit Receive 1001 Tx Transmit only 1002 Standby Spare 13 3 5HP_HostedEthernetTeam HP_HostedEthernetTeam associates Ethernet T...

Страница 146: ... created from an individual port Caption is the marketing name of the individual NIC Examples Windows VLAN1 BL870c LoM 5704 Caption BL870c LoM 5704 Description Local Area Connection ElementName Same as Caption CIM_ManagedSystemElement Key Name System GUID for the Ethernet LAN Endpoint 5 OK HealthState 15 Degraded Warning 20 Major Failure 2 OK OperationalStatus 0 3 Degraded 6 Error CIM_LogicalEleme...

Страница 147: ...perty name Property implementation CIM_Dependency Key Antecedent ref HP_EthernetPort Key Dependent ref HP_EthernetLANEndtpoint CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint 13 3 8HP_EthernetTeamToLANEndpoint HP_ EthernetTeamToLANEndpoint associates Ethernet Teams to Ethernet LAN Endpoints The Windows implementation class is HP_WinEthRedundancySetToLANEndpoint Table 13 9 Class HP_Etherne...

Страница 148: ...y name Property implementation CIM_SAPSAPDependency CIM_BindsTo CIM_BindsToLANEndpoint FrameType 1 Ethernet HP_IPBindsToEthernetLANEndpoint Key Antecedent ref HP_EthernetLANEndpoint Key Dependent ref CIM_IPProtocolEndpoint 13 3 11HP_EthernetStatistics The following table lists the property implementation for HP_EthernetPortStatistics The Windows implementation class is HP_WinEthernetPortStatistics...

Страница 149: ... the CIM_EthernetPortStatistics mof InternalMACTransmitErrors See the CIM_EthernetPortStatistics mof LateCollisions See the CIM_EthernetPortStatistics mof MultipleCollisionFrames See the CIM_EthernetPortStatistics mof SingleCollisionFrames See the CIM_EthernetPortStatistics mof HP_EthernetStatistics 13 3 12HP_EthernetPortStatisticalData HP_EthernetPortToStatisticalData associates Ethernet Ports an...

Страница 150: ...iption Ethernet Adapter Collection ElementName Ethernet Adapter Collection CIM_Collection CIM_SystemSpecificCollection Key InstanceId ad498944 762f 11d0 8dcb 00c04fc3358c HP_GroupSystemSpecificCollection GroupOperationalStatus See the Ethernet Teaming Profile GroupStatusDescriptions See the Ethernet Teaming Profile HP_EthernetCollection 13 3 15HP_EthernetMemberOfCollection HP_EthernetMemberOfColle...

Страница 151: ...f HP_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 13 3 17CIM_IPProtocolEndpoint The following table lists the property implementation for CIM_IPProtocolEndpoint The Windows implementation class is HP_WinEthIPProtocolEndpoint Table 13 18 Class CIM_IPProtocolEndpoint Property name Property implementation CIM_ManagedElement Caption Same as associated L...

Страница 152: ...tocolIfType 4097 IPv6 SubnetMask Subnet Mask 13 3 18HP_EthIPHostedAccessPoint CIM_HostedAccessPoint associates IP Protocol Endpoints to the Computer System The Windows implementation class is HP_WinEthIPHostedAccessPoint Table 13 19 Class HP_EthIPHostedAccessPoint Property name Property implementation CIM_HostedDependency Key Antecedent ref HP_ComputerSystem Key Dependent ref CIM_IPProtocolEndpoin...

Страница 153: ...entityInfoType CIM SoftwareFamily IdentityInfoValue 0 HPQ PCI Vendor Id IsEntity Always set to false MajorVersion Major number component of the Boot Code or PXE Manufacturer Hewlett Packard Company MinorVersion Minor number component of the Boot Code or PXE TargetType Vendor PCI ID VersionString Version of Boot Code or PXE 13 3 20CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates F...

Страница 154: ...pter location For example for cellular systems Cabinet 0 Bay 0 Chassis 1 Slot 2 Port 1 Cabinet 0 Bay 0 Chassis 0 Slot 0 For example for non cellular systems Slot 0 Slot 2 Port 1 CIM_Location Key Name Local Area Connection Key PhysicalPostion System GUID for the associated Ethernet Port HP_Location ElementLocationTag PCI Bus Device Function ElementLocationTagDesc 15 PCI Bus Device Function 0 Slot L...

Страница 155: ...et Event Provider configurable settings for Windows Key InstanceId 0 HP_EthEventSettings HP_WinEthEventSettings ActiveAdapterCountChanged If enabled an event is generated when a change is detected in number of active adapter count of a team Default disabled FloodThreshold Time in seconds used for indication flood control Default 10 seconds InterfaceAvailable If enabled an event is generated when a...

Страница 156: ...ications are implemented for Integrity server platforms where available System Ethernet Port Ethernet Team and Ethernet LAN Endpoint indications are described in the following For nonteamed Ethernet Ports if the associated HP_EthernetMemberOfCollection Included is False the following indications are disabled For teamed Ethernet Ports this association does not exist For Ethernet Teams where the ass...

Страница 157: ...rnet Team NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the indication in the for...

Страница 158: ...g when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 13 4 2Ethernet Team Redundancy Increased Table 13 26 HP_AlertIndication Ethernet Team Redundancy Increased Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeveri...

Страница 159: ...ystem generating the indication in the format major minor build ProviderVersion Provider version generating the indication in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemModel Model name of the computer system generating the indication Syst...

Страница 160: ...on IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 Major IndicationTime Time of indication CIM_AlertIndication Description An Ethernet team s redundancy has decreased A team member has changed to failed or degraded state AlertingManagedElement WBEM path of the Ethernet Team HP_WinEthRedundancySet reporting decreased redundancy AlertingElementFormat 2 CIMObjectPath Aler...

Страница 161: ... SystemGUID Platform GUID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableName 0 FailedMemberPath VariableTypes 0 1 string VariableValues 0 WBEM path of the fail...

Страница 162: ... Ethernet team member status changed from Error or Degraded to OK AlertingManagedElement WBEM path of the Ethernet Team HP_WinEthRedundancySet reporting full redundancy restored AlertingElementFormat 2 CIMObjectPath AlertType 2 Communications Alert Event Id 15 ProbableCause 1 Other ProbableCauseDescription Ethernet Team Redundancy Status Changed to Fully Redundant Provider Name HP Ethernet Recomme...

Страница 163: ...stem generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableName 0 RecoveredMemberPath VariableTypes 0 1 string VariableValues 0 WBEM path of the recovered Ethernet Port HP_WinEthernetPort 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with a...

Страница 164: ... ProbableCause 7 Communications Subsystem Failure ProbableCauseDescription Network Interface Lost Connectivity Provider Name HP Ethernet RecommendedActions Check the network cables switches and hubs for the cause of the failure SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndicati...

Страница 165: ...ertingManagedElement is an Ethernet Team VariableValues 0 WBEM path of the failed Ethernet Port HP_WinEthernetPort implemented only if AlertingManagedElement is an Ethernet Team 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName...

Страница 166: ... Connectivity now Restored Provider Name HP Ethernet RecommendedActions No action is recommended SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary Network connectivity restored EventCategory 9 Network Device EventSubCategory 11 Ethernet Port 12 Ethernet Team NetworkA...

Страница 167: ...t is an Ethernet Team 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSe...

Страница 168: ...nal information SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary Ethernet team member reported status change EventCategory 9 Network Device EventSubCategory 12 Ethernet Team NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generat...

Страница 169: ...VariableName 2 PreviousStatusDetail VariableTypes 2 1 string VariableValue 2 Previous HP_WinEthernetTeamMember MemberStatusDescriptio ns 0 VariableName 3 CurrentStatus VariableTypes 3 1 string VariableValue 3 Current HP_WinEthernetTeamMember MemberOperationalStat us 0 VariableName 4 CurrentStatusDetail VariableTypes 4 1 string VariableValue 4 Current HP_WinEthernetTeamMember MemberStatusDescriptio...

Страница 170: ...of indication CIM_AlertIndication Description An Ethernet Team member s role has changed This is an optional indication that can be disabled through the Ethernet Event Provider settings AlertingManagedElement WBEM path of the Ethernet Team HP_WinEthRedundancySet reporting a member role change AlertingElementFormat 2 CIMObjectPath AlertType 2 Communications Alert Event Id 9 ProbableCause 1 Other Pr...

Страница 171: ...er system generating the indication SystemModel Model name of the computer system generating the indication SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableNames 0 MemberPath VariableTypes 0 1 string VariableValues 0 WBEM Path Port HP_WinEthernetPort whose role has changed Variable...

Страница 172: ... PerceivedSeverity 2 Information IndicationTime Time of indication CIM_AlertIndication Description An Ethernet Team member has been dropped from the team through the HP Network Configuration Utility NCU This is an optional indication that can be disabled through the Ethernet Event Provider settings AlertingManagedElement WBEM Path Team HP_WinEthRedundancySet reporting a dropped team member Alertin...

Страница 173: ...ystemGUID Platform GUID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableNames 0 MemberPath VariableTypes 0 1 string VariableValues 0 WBEM path of the Ethernet Po...

Страница 174: ...tion Utility NCU This is an optional indication that can be disabled through the Ethernet Event Provider settings AlertingManagedElement WBEM path of the Ethernet Team HP_WinEthRedundancySet reporting lost redundancy AlertingElementFormat 2 CIMObjectPath AlertType 2 Communications Alert Event Id 7 ProbableCause 1 Other ProbableCauseDescription Ethernet Team Member Added to Team Provider Name HP Et...

Страница 175: ...m generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableNames 0 MemberPath VariableTypes 0 1 string VariableValues 0 WBEM path of the Ethernet Port HP_WinEthernetPort added to the team 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are ...

Страница 176: ...2 CIMObjectPath AlertType 2 Communications Alert Event Id 12 ProbableCause 1 Other ProbableCauseDescription Network Interface Unavailable Provider Name HP Ethernet RecommendedActions Ensure the network interface was made unavailable intentionally SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indicati...

Страница 177: ...main 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial n...

Страница 178: ...ndedActions No action is recommended SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary New network interface available EventCategory 9 Network Device 11 Ethernet Port EventSubCategory 12 Ethernet Team 13 Ethernet LAN Endpoint NetworkAddresses A list of all the IP add...

Страница 179: ...ists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 13 4 13Ethernet Team Active Member Count Change Table 13 37 HP_AlertIndication Ethernet Team Active Member Count Change Property na...

Страница 180: ... Network Device EventSubCategory 12 Ethernet Team NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider vers...

Страница 181: ...ialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 13 4 14Ethernet Provider Fatal Error Table 13 38 Optional HP_AlertIndication Ethernet Provider Fatal Error Property name Property implementation CIM_Ind...

Страница 182: ...Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the indication in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemG...

Страница 183: ...er string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 13 4 15Ethernet Provider Cannot Access Data Source Table 13 39 Optional HP_AlertIndication Ethernet Provider Cannot Access Data Source Property name Property implementation CIM_Indication IndicationIdentifier GUID string gen...

Страница 184: ...g the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the indication in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system generating th...

Страница 185: ...ladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment ...

Страница 186: ...ratingSystem HP_OperatingSystem implements the class CIM_OperatingSystem to model the currently running Operating System The following properties are implemented Table 14 2 Class HP_OperatingSystem Property name Property implementation CIM_ManagedElement Caption Microsoft Windows Server 2008 Standard same as Win32_OperatingSystem Caption Microsoft R Windows R Server 2003 Datacenter Edition for 64 ...

Страница 187: ...plicable CIM_OperatingSystem CreationClassName HP_OperatingSystem CSCreationClassName HP_WinComputerSystem CSName Computer system name from Windows API GetComputerSystemName CurrentTimeZone Number of minutes offset from GMT Distributed TRUE if operating system is distributed across multiple computer system nodes FreePhysicalMemory Number of Kbytes of physical memory currently unused and available ...

Страница 188: ...perties are implemented Table 14 3 Class CIM_RunningOS CIM_Dependency CIM_RunningOS Antecedent ref HP_OperatingSystem Dependent ref HP_ComputerSystem 14 3 3CIM_InstalledOS The class CIM_InstalledOS associates the HP_ComputerSystem class instance to the CIM_OperatingSystem instance There is only one instance of the CIM_InstalledOS instantiated only the currectly running OS is instantiated The follo...

Страница 189: ...of HPWMISA_HP mof HPWMISAEvent mof HPWMISA_R mof HPSAErrorMetaData mof 15 2 Use cases For use cases see the HP Smart Array Profile P00121 This provider implements a read only version of the profiles referenced Configuration functionality is not supported by this provider This is in accordance with the SNIA profiles because HP does not advertise and ConfigurationService type classes 15 3Class imple...

Страница 190: ...er the algorithm desciribed in the HP Smart Array Profile 0 Unknown 2 OK 3 Degraded 6 Error StatusDescriptions 0 More information for OperationalStatus result This provides a short decription to identify who is contributing to non OK status Examples Logical Drive Failure Physical Drive Degraded Failed CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicab...

Страница 191: ...MBEDDED Reported if there is no Serial Number for the local device embedded on the motherboard PCISLOTSlot number Reported if there is no Serial Number for the local device PCI occupies a slot OperationalStatus 0 Status for Array Controller 0 Unknown 2 OK 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM...

Страница 192: ...Profile NumberOfInternalPorts See HP Smart Array Profile NumberOfExternalPorts See HP Smart Array Profile NumberOfPorts See HP Smart Array Profile RebuildPriority See HP Smart Array Profile 15 3 3HPSA_StorageVolume HPSA_StorageVolume represents the Logical Volumes configured on the Smart Array Table 15 4 Class HPSA_StorageVolume CIM_StorageVolume Property name Property implementation CIM_ManagedEl...

Страница 193: ...ancy 2 RAID 1 0 DeltaReservation 0 ExtentStatus 0 This indicates extended status for the volume 2 None 11 Rebuild Volume is currently rebuilding data IsBasedOnUnderlyingRedundancy False True RAID 1 or above NoSinglePointOfFailure False RAID 0 NumberOfBlocks Total Number of blocks on the volume NameFormat 2 VPD83NAA6 0 RAID 0 PackageRedundancy 1 RAID 1 0 RAID 5 2 RAID 6 RAID 50 CIM_Storagevolume HP...

Страница 194: ... is currently not redundant possibly due to failure of 1 or more paths or a configuration error Primordial False Can create and delete this element 15 3 4HPSA_DiskDrive HPSA_DiskDrive represents the Hard drives connected to Smart Array controllers Table 15 5 Class HPSA_DiskDrive CIM_DiskDrive Property name Property implementation CIM_ManagedElement ElementName Disk location Examples Port 1E Box 1 ...

Страница 195: ...r of service hours logged for the drive CIM_MediaAccessDevice CIM_DiskDrive HPSA_DiskDrive DriveConfiguration See HP Smart Array Profile DriveHasMNPData See HP Smart Array Profile DriveInterface See HP Smart Array Profile DrivePlacement See HP Smart Array Profile DriveRotationalSpeed See HP Smart Array Profile NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed See HP Smart Array Profil...

Страница 196: ...dSystemElement Name Serial number of drive OperationalStatus 0 Operational Status for the disk drive 0 Unknown 2 OK 5 Predictive Failure 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName HPSA_StorageExtent DeviceID Opaque ID SystemCreationClassName HPSA_ArraySystem SystemN...

Страница 197: ...irmware CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions 0 Disk Drive Firmware Classifications 0 10 Firmware InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType CIM SoftwareFamily IdentityInfoValue HPQ TargetType value VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmwa...

Страница 198: ... for HBAs If the serial number is not available and if the controller is sitting in slot 0 this field displays EMBEDDED Chassis serial number for External subsystems Tag HBA Subsystem Serial number Version Not populated Not available for this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable HPSA_PhysicalPackage 15 3 8HPSA_ArrayControllerPhysicalPackage HPSA_ArrayControllerPhys...

Страница 199: ... A If the controller is sitting in slot 0 this field displays EMBEDDED Tag Opaque key Version N A Not Available for this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable HPSA_ ArrayControllerPhysicalPackage 15 3 9HPSA_DiskPhysicalPackage HPSA_DiskPhysicalPackage represents the physical aspects of the disk drive There is one instance per disk drive Table 15 10 Class HPSA_DiskPh...

Страница 200: ...geEnclosure HP_StorageEnclosure Property name Property implementation CIM_ManagedElement ElementName Port m1 m2 Box n where m1 is the active port m2 is the passive port number and n is the box number For dual port SAS disks both port numbers are displayed CIM_ManagedSystemElement Name Port m1 m2 Box n where m1 is the active port m2 is the passive port number and n is the box number For dual port S...

Страница 201: ...eEnclosureProcessor CIM_ComputerSystem Property name Property implementation CIM_ManagedElement ElementName Port m1 m2 Box n where m1 is the active port m2 is the passive port number and n is the box number For dual port SAS disks both port numbers are displayed CIM_ManagedSystemElement OperationalStatus 0 1 2 3 Operational status for enclosure and associated power supplies fans and sensors The us...

Страница 202: ...icated 0 2 Other IdentifyingDescriptions 0 Other Vendor Specific Name OtherDedicatedDescriptions 0 SDE Indicates Storage Device Enclosure HPSA_StorageEnclosureProcessor 15 3 12HPSA_PortController HPSA_PortController represent the HBA in the host system There is one instance per HBA Note This class is not implemented for external subsystems for example MSA500 Table 15 13 Class HPSA_PortController C...

Страница 203: ... front end port for an HBA in the host system Direct Attached implies that the array controller is attached to a local bus on the host for example PCI Table 15 14 Class HPSA_DAPort CIM_DAPort Property name Property implementation CIM_ManagedElement ElementName Controller name and location for example Smart Array in Slot 3 CIM_ManagedSystemElement OperationalStatus 0 Port status 0 Unknown 2 OK 6 Er...

Страница 204: ...tem SPI implies that the subsystem is connected through SCSI Parallel Interface to the Host Table 15 15 Class HPSA_SPIPort CIM_SPIPort Property name Property implementation CIM_ManagedElement ElementName Storage System name and location for example MSA500 in SystemCab03 CIM_ManagedSystemElement OperationalStatus 0 Port status 0 Unknown 2 OK 6 Error CIM_LogicalElement CIM_EnabledLogicalElement Enab...

Страница 205: ...ManagedSystemElement Name Array Controller Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions 0 Array Controller Firmware Classifications 0 10 Firmware InstanceID Opaque key Manufacturer Controller vendor string IdentityInfoType CIM SoftwareFamily IdentityInfoValue HPQ TargetType value subsystemID and VendorId combination VersionString Controller firmware version string HP...

Страница 206: ...etType value VersionString Enclosure firmware string HPSA_EnclosureFirmware 15 3 17HPSA_PrimordialPool HPSA_PrimordialPool represents the total raw storage managed by the array controller There is one instance per array system Table 15 18 Class HPSA_PrimordialPool CIM_StoragePool Property name Property implementation CIM_ManagedElement ElementName Controller name and location pool identifier for e...

Страница 207: ...roller name and location pool identifier for example Smart Array in Slot 3 Array 0 CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number n where n is the array number as supplied from the API Primordial Always set to FALSE RemainingManagedSpace Remaining raw space in current pool TotalManagedSpace Total raw space managed by this pool HPSA...

Страница 208: ...mart Array Profile HardwareErrors See HP Smart Array Profile HardWriteErrors See HP Smart Array Profile HotPlugCount See HP Smart Array Profile MediaFailures See HP Smart Array Profile NotReadyErrors See HP Smart Array Profile OtherTimeOuts See HP Smart Array Profile SCSIBusFaults See HP Smart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Array Profile SeekCount ...

Страница 209: ...ncyMax 2 RAID 1 0 1 RAID 0 RAID 5 RAID 6 RAID 50 RAID 60 DataRedundancyMin 2 RAID 1 0 DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 FALSE RAID 0 NoSinglePointOfFailure TRUE RAID 1 0 RAID 5 RAID 6 RAID 50 RAID 60 0 RAID 0 PackageRedundancyGoal 1 RAID 1 0 RAID 5 2 RAID 6 0 RAID 0 PackageRedundancyMax 1 RAID 1 0 RAID 5 2 RAID 6 RAID 50 RAID 60 0 RAID 0 PackageRedundancyMin 1 RAID...

Страница 210: ...Name HPSA_DriveCage Manufacturer Drive Cage Vendor string Model Drive Cage Model string PartNumber Not populated Not available in this implementation Tag Opaque key SerialNumber Enclosure Serial number Version Nor populated Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable HP_DriveCage BackplaneSpeed See profile DriveBays See profile DuplexLocation See pro...

Страница 211: ...Endpoint ProtocolIFType 0 Unknown CIM_SCSIProtocolEndpoint ConnectionType The supported connection type for this endpoint 1 Other 3 Parallel SCSI for SCSI controllers 8 SAS for SAS controllers OtherConnectionType The connection type if ConnectionType is 1 Other 0 Unknown Role 2 Initiator 3 Target 4 Both Initiator and Target HPSA_SCSIProtocolEndpoint 15 3 23HPSA_SCSIProtocolController HPSA_SCSIProt...

Страница 212: ...PSA_ArraySystem SystemName HPSA_ArraySystem Name CIM_ProtocolController MaxUnitsControlled 32 CIM_ SCSIProtocolController HPSA_ SCSIProtocolController 15 3 24HPSA_RedundancySet HPSA_RedundancySet represents controller redundancy if there is more than one controller in a redundant configuration for example MSA500 with two controllers Table 15 25 Class HPSA_RedundancySet CIM_RedundancySet Property n...

Страница 213: ...y implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 No Load Balancing MaxNumberSupported 0 MinNumberNeeded 0 2 Fully Redundant RedundancyStatus 4 Redundancy Lost TypeOfSet 0 5 Limited Sparing CIM_StorageRedundancySet HPSA_StorageRedundancySet 15 3 26HPSA_StorageSpecificColl...

Страница 214: ...for information on how this is calculated GroupStatusDescriptions 0 Description of GroupOperationalStatus HPSA_ StorageSpecificCollection 15 3 27HPSA_DriveCageLocation HPSA_DriveCageLocation represents a location string for the drive cage Table 15 28 Class HPSA_DriveCageLocation HP_Location Property name Property implementation CIM_ManagedElement Caption Drive Cage Description Drive Cage ElementNa...

Страница 215: ...or internal MSA500 in SystemCab03 for external ElementName Controller name and location Examples Smart Array in Slot 3 for internal MSA500 in SystemCab03 for external CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location PCI Slot Number when Adapter is specified in ElementLocationTagDesc ElementLocationTag Chassis Name when Chassis is specified in ElementLocationTagDesc 23 Adapter f...

Страница 216: ...cation Examples Smart Array E500 Physical Drive Port 1E Box 1 Bay 5 Smart Array E500 Physical Drive Port 1E 2E Box 1 Bay 5 SAS disk with dual port CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location Bay Number of Disk Drive When Bay is specified in ElementLocationTagDesc ElementLocationTag SCSI ID of Disk Drive When SCSI ID is specified in ElementLocationTagDesc 20 Bay When firmwa...

Страница 217: ...e Controller MSA500 in SystemCab03 for external CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag for Internal HBAs PCI Slot Number Examples 3 for adapter in PCI Slot 3 0 for Embedded adapter For external controllers Controller number per chassis label Examples Controller 1 Controller 2 23 Adapter for Internal HBAs ElementLocationTagDesc 1 Hood Tag for Externa...

Страница 218: ...tanceID Key Opaque key CIM_StorageCapabilities 1 When number of drives is an odd number DataRedundancyDefault 2 When number of drives is an even number For example pool can be configured for mirroring 0 When there is no drives connected 1 When number of drives is an odd number DataRedundancyMax 2 When number of drives is an even number For example Pool can be configured for mirroring 0 When there ...

Страница 219: ...oduct CIM_Product Property name Property implementation CIM_ManagedElement ElementName Controller name and location Examples Smart Array in Slot 3 for internal MSA500 in SystemCab03 for external CIM_Product IdentifyingNumber Opaque key Name String representing the Marketing name Vendor HP Version Firmware version of HBA or Storage System HPSA_Product 15 3 33HPSA_StorageEnclosure Location HPSA_Stor...

Страница 220: ...onTagDesc 19 Box 15 3 34HPSA_TSASSCSIProtocolEndpoint HPSA_TSASSCSIProtocolEndPoint represents each port on SAS Drive This class is generated only if the SAS controller connected to the disk has multipath supported firmware Table 15 35 Class HPSA_TSASSCSIProtocolEndpoint Property name Property implementation CIM_SCSIProtocolEndpoint CIM_ManagedElement ElementName Protocol Endpoint for xxx where xx...

Страница 221: ...ServiceAccessPoint HPSA_ArraySystem SystemnCreationClassName SystemName The property value of HP_ArraySystem name HPSA_TSASSCSIProtocolEndpoint CreationClassName CIM_EnabledLogicalElement EnabledDefault 2 Enabled RequestedState 12 Not Applicable HPSA_SCSIProtocolEndpoint ProtocolIFType 1 Other SCSI OtherTypeDescription Role 3 Target HPSA_TSASSCSIProtocolEndpoint Path Redundancy path status 0 Unkno...

Страница 222: ...ASSCSIPE CIM_SCSIProtocolEndpoint ProtocolIFType 1 Other SCSI OtherTypeDescription Role 2 Initiator 15 3 36HPSA_TSASPort This class is generated only if the SAS controller connected to this disk drive has multipath supported firmware Table 15 37 Class HPSA_TSASPort Property name Property implementation CIM_ManagedElement Caption Port unique_index where unique_index is a unique index across all por...

Страница 223: ...Table 15 38 Class HPSA_ISASPort Property name Property implementation CIM_ManagedElement Caption Port port where port is the port number for example 1E 2E ElementName Port port where port is the port number for example 1E 2E CIM_ManagedSystemElement OperationalStatus 2 OK For multipath supported firmware implementations the status of the port is always OK and the status of the path is the only thi...

Страница 224: ...991 1E PH77MW3991 2E CIM_LogicalPort UsageRestriction 4 Not restricted PortType 94 SAS CIM_SASPort PermanentAddress Not supported 15 3 38HPSA_ArraySystemRedundancySet Association Table 15 39 Class HPSA_ArraySystemRedundancySet CIM_ConcreteIdentity Property name Property implementation SameElement HPSA_RedundancySet SystemElement HPSA_ArraySystem 15 3 39HPSA_StorageVolumeStorageSetting Association ...

Страница 225: ...SystemStorageEnclosureProcessor Association Table 15 43 Class HPSA_ArraySystemStorageEnclosureProcessor CIM_SystemComponent Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StorageEnclosureProcessor 15 3 43HPSA_ArraySystemSCSIProtocolController Association Table 15 44 Class HPSA_ArraySystemSCSIProtocolController CIM_SystemDevice Property name Property implem...

Страница 226: ...5 47 Class HPSA_ArraySystemStorageVolume CIM_SystemDevice Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StorageVolume 15 3 47HPSA_ArraySystemStorageExtent Association Table 15 48 Class HPSA_ArraySystemStorageExtent CIM_SystemDevice Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StorageExtent 15 3 48HPSA_ArraySyste...

Страница 227: ...Pool Association Table 15 52 Class HPSA_ArraySystemStoragePool CIM_HostedStoragePool Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StoragePool 15 3 52HPSA_ComputerSystemArraySystem Association Table 15 53 Class HPSA_ComputerSystemArraySystem CIM_ComponentCS Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HPSA_ArrayS...

Страница 228: ...ementation GroupComponent HPSA_Product PartComponent HPSA_PhysicalPackage 15 3 56HPSA_StorageEnclosureDriveCage Association Table 15 57 Class HPSA_StorageEnclosureDriveCage CIM_Container Property name Property implementation GroupComponent HPSA_StorageEnclosure PartComponent HPSA_DriveCage 15 3 57HPSA_PhysicalPackageArrayControllerPhysicalPackag e Association Table 15 58 Class HPSA_PhysicalPackage...

Страница 229: ...eDiskPhysicalPackage Association Table 15 61 Class HPSA_DriveCageDiskPhysicalPackage CIM_Container Property name Property implementation GroupComponent HPSA_DriveCage PartComponent HPSA_DiskPhysicalPackage 15 3 61HPSA_StoragePoolStorageExtent Association Table 15 62 Class HPSA_StoragePoolStorageExtent CIM_ConcreteComponent Property name Property implementation GroupComponent HPSA_StoragePool PartC...

Страница 230: ...ty name Property implementation Collection HPSA_RedundancySet Member HPSA_ArrayController 15 3 65HPSA_StorageRedundancySetStorageExtent Association Table 15 66 Class HPSA_StorageRedundancySetStorageExtent CIM_MemberOfCollection Property name Property implementation Collection HPSA_StorageRedundancySet Member HPSA_StorageExtent 15 3 66HPSA_ArraySystemFirmware Association Table 15 67 Class HPSA_Arra...

Страница 231: ...ElementSoftwareStatus ElementSoftwareStatus 1 6 Installed 15 3 69HPSA_StorageEnclosureProcessorEnclosureFirmware Association Table 15 70 Class HPSA_StorageEnclosureProcessorEnclosureFirmware CIM_ElementSoftwareIdentity Property name Property implementation Antecedent HPSA_EnclosureFirmware Dependent HPSA_StorageEnclosureProcessor ElementSoftwareStatus 0 2 Current ElementSoftwareStatus ElementSoftw...

Страница 232: ...ePoolStorageVolume Association Table 15 74 Class HPSA_StoragePoolStorageVolume CIM_AllocatedFromStoragePool Property name Property implementation Antecedent HPSA_StoragePool Dependent HPSA_StorageVolume SpaceConsumed Bytes consumed by volume 15 3 74HPSA_PrimordialPoolStoragePool Association Table 15 75 Class HPSA_PrimordialPoolStoragePool CIM_AllocatedFromStoragePool Property name Property impleme...

Страница 233: ...Volume Association Table 15 78 Class HPSA_StorageExtentStorageVolume CIM_BasedOn Property name Property implementation Antecedent HPSA_StorageExtent Dependent HPSA_StorageVolume 15 3 78HPSA_DAPortSCSIProtocolEndpoint Association Table 15 79 Class HPSA_DAPortSCSIProtocolEndpoint CIM_DeviceSAPImplementation Property name Property implementation Antecedent HPSA_DAPort Dependent HPSA_SCSIProtocolEndpo...

Страница 234: ...A_PhysicalPackage Dependent HPSA_ArraySystem 15 3 82HPSA_ArrayControllerPhysicalPackageArrayController Association Table 15 83 Class HPSA_ArrayControllerPhysicalPackageArrayController CIM_ComputerSystemPackage Property name Property implementation Antecedent HPSA_ArrayControllerPhysicalPackage Dependent HPSA_ArrayController 15 3 83HPSA_DiskDriveMediaAccessStatData Association Table 15 84 Class HPS...

Страница 235: ...on Element HPSA_PhysicalPackage PhysicalLocation HPSA_ArraySystemLocation 15 3 86HPSA_DriveCageDriveCageLocation Association Table 15 87 Class HPSA_DriveCageDriveCageLocation CIM_PhysicalElementLocation Property name Property implementation Element HPSA_DriveCage PhysicalLocation HPSA_DriveCageLocation 15 3 87HPSA_DiskPhysicalPackageDiskDriveLocation Association Table 15 88 Class HPSA_DiskPhysical...

Страница 236: ...ass HPSA_ISASPortISASSCSIProtocolEndPoint CIM_DeviceSAPImplementation Property name Property implementation Antecedent Points to reference of HPSA_ISASPort Dependent Points to reference of HPSA_ISASSCSIProtocolEndpoint 15 3 91HPSA_ArraySystemISASSCSIProtocolEndPoint Association Table 15 92 Class HPSA_ArraySystemISASSCSIProtocolEndpoint CIM_HostedAccessPoint Property name Property implementation An...

Страница 237: ...ation Antecedent Points to reference of HPSA_ArraySystems Dependent Points to reference of TSASSCSIProtocolEndpoint 15 3 95HPSA_TSASPortISASSCSIProtocolEndpoint Association Table 15 96 Class HPSA_ArraySystemTSASSCSIProtocolEndpoint CIM_HostedAccessPoint Property name Property implementation Antecedent Points to reference of HPSA_TSASPort Dependent Points to reference of TSASSCSIProtocolEndpoint 15...

Страница 238: ...UnitPath Property name Property implementation Initiator Reference to aninstance of HPSA_ISASSCSIProtocolEndpoint Target Reference to an instance of HPSA_TSASSCSIProtocolEndpoint LogicalUnit Reference to an instance of HPSA_StorageExtent 0 unknown if the path status cannot be ascertained State 2 active if the path is active and healthy 5 Path Error path has an error condition 3 passive path is hea...

Страница 239: ...imary Storage ProbableCause 1 Other Physical Drive Status Changed to OK ProbableCauseDescription NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format ...

Страница 240: ...tion LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when ...

Страница 241: ...led or removed physical drives SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive status Error EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription Physical Drive Status Changed to Error NetworkAddresses A list of all t...

Страница 242: ...ive DriveInterface 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSeria...

Страница 243: ... Rebuilding Data is now being rebuilt onto this drive from the RAID set AlertingMangedElement WBEM path of the HPSA_DiskDrive class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 203 ProviderName HP SmartArray RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer...

Страница 244: ...LastFailureDescription VariableNames 2 DriveInterface VariableTypes 0 1 String VariableTypes VariableTypes 1 1 String VariableTypes 2 4 uint16 VariableValues 0 Short Description of failure VariableValues VariableValues 1 Short Description of last failure VariableValues 2 HPSA_DiskDrive DriveInterface 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedD...

Страница 245: ...URE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 Major IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure AlertingMangedElement WBEM path of the HPSA_DiskDrive class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert E...

Страница 246: ...e computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames 0 FailureDescription VariableNames VariableNames 1 LastFailureDescription VariableNames 2 DriveInterface VariableTypes 0...

Страница 247: ...ontroller Location For example SmartArray 642 in Slot 2 HWManufacturer Compaq HWSerialNumber Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string 15 4 5Logical Drive Status Changed to OK Table 15 104 HPSA_StorageVolumeIndication Logical Drive status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the...

Страница 248: ...ion in the format major minor build ProviderVersion Provider version generating the information in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model n...

Страница 249: ...lStatus 0 HPSA_StorageVolume OperationalStatus 0 DeviceOperationalStatus 1 HPSA_StorageVolume OperationalStatus 1 This index is only populated if there is addional Vendor unique status available DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume DeviceOperationalStatusPrevious 0 HPSA_StorageVolume OperationalStatus 0 DeviceOperationalStatusPrevious 1 HPSA_StorageV...

Страница 250: ...atus Changed to Error NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the informati...

Страница 251: ...ning the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Logical drive number and RAID Level for example LogicalDrive 1 RAID 1 0 HP_DeviceIndication HPSA_StorageVolumeIndication DeviceOperationalStatus Current OperationStatus values for Storage Volume DeviceOperationalStatus 0 HPSA_StorageVolume OperationalStatus 0 DeviceOperationalStatus 1...

Страница 252: ... recovery operation on one or more physical drives SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical Drive in degraded state EventCategory 6 Primary Storage ProbableCause 86 Disk Failure NetworkAddresses A list of all the IP addresses IPV4 and IPv6 of the com...

Страница 253: ...P_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual syst...

Страница 254: ...ceivedSeverity 3 Degraded Warning IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from non OK to OK AlertingMangedElement WBEM path to the HPSA_ArrayController class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartAr...

Страница 255: ...ter system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames 0 FailureDescription VariableNames VariableNames 1 CacheSizeTotal VariableNames 2 CacheSerialNumber VariableTypes 0 1 String VariableTypes VariableTypes 1 5 uint16 VariableTypes 2 1 String VariableValues 0 Short Description of failure VariableValues VariableValues 1 HPSA_Arr...

Страница 256: ...Array Controller Model string 15 4 9Controller Status Changed to ERROR Table 15 108 HPSA_DeviceIndication Controller status changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 Major IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed t...

Страница 257: ...the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames 0 FailureDescription VariableNames V...

Страница 258: ...on Array Controller Location string For example Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string 15 4 10Controller Redundancy State Has Been Set to ACTIVE Table 15 109 HPSA_DeviceIndication Controller Redundancy state has been set to ACTIVE Property name Propert...

Страница 259: ... generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the information in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system ge...

Страница 260: ...e Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Cont...

Страница 261: ...ating the indication HP_AlertIndication Summary Controller redundancy lost EventCategory 6 Primary Storage ProbableCause 1 Other ProbableCauseDescription Array Controller Redundancy has been Lost NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2...

Страница 262: ...em for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number strin...

Страница 263: ...ray RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller redundancy restored EventCategory 6 Primary Storage ProbableCause 1 Other ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddres...

Страница 264: ...lues 2 HPSA_ArrayController CacheSerialNumber Note In some cases the VariableValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name Rac...

Страница 265: ...controller Battery status has changed from non OK to OK AlertingMangedElement WBEM path to the HPSA_ArrayController class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 6 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended SystemName Name of the computer system generating the ind...

Страница 266: ...omputer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames 0 FailureDescription VariableNames VariableNames 1 CacheSizeTotal VariableNames 2 CacheSerialNumber VariableTypes 0 1 String VariableTypes VariableTypes 1 5 uint16 VariableTypes 2 1 String VariableValues 0 Short Description of failure VariableValues VariableValues 1 HPSA...

Страница 267: ...ion DeviceModel Array Controller Model string 15 4 14Controller Battery Status Changed to Not Fully Charged Table 15 113 HPSA_DeviceIndication Controller Battery status changed to not fully charged Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at time of indication PerceivedSeverity 3 Warning IndicationTime Time of indication CIM_AlertIndication De...

Страница 268: ...ormat major minor build ProviderVersion Provider version generating the information in the form major minor revision build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the c...

Страница 269: ...the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string...

Страница 270: ... A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the information in the form major minor revision bu...

Страница 271: ...System Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_Hard...

Страница 272: ...ation HP_AlertIndication Summary Controller cache status OK EventCategory 6 Primary Storage ProbableCause 1 Other ProbableCauseDescription Controller Cache Status Changed to OK NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operatin...

Страница 273: ...tem for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number stri...

Страница 274: ...r time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Array controller cache status temporarily disabled EventCategory 6 Primary Storage ProbableCause 3...

Страница 275: ...leValues 0 Short Description of failure VariableValues VariableValues 1 HPSA_ArrayController CacheSizeTotal VariableValues 2 HPSA_ArrayController CacheSerialNumber Note In some cases the VariableValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBa...

Страница 276: ...ing IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed to Permanently Disabled The controller has detected a problem with the cache and has disabled the cache permanently AlertingMangedElement WBEM path to the HPSA_ArrayController class AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 11 EventTime Time of the ev...

Страница 277: ...ber of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames 0 FailureDescription VariableNames VariableNames 1 CacheSizeTotal VariableNames 2 CacheSerialNumber VariableTyp...

Страница 278: ... example Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string 15 4 19Enclosure Power Supply Status Changed to Non Redundant Table 15 118 HPSA_DeviceIndication Enclosure Power Supply status changed to Non Redundant Property name Property implementation CIM_Indication...

Страница 279: ...dresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the information in the form major minor revision build SystemFirmwareVersio...

Страница 280: ...emVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 15 4 20Enclosure Power Supply Status Changed to OK Redundant Table 15 119 HPSA_DeviceIndication En...

Страница 281: ...f the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the information in the form major minor revision build SystemFirmwareVersion Firmware version of t...

Страница 282: ...Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 15 4 21Enclosure Power Supply Status Changed to Redundant Degraded Table 15 120 HPSA_DeviceIndication Enclosure ...

Страница 283: ...ableCauseDescription Redundant Power Supply Degraded NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 70 Windows Server 2003 64 bit OSType 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider v...

Страница 284: ...erial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 15 4 22Enclosure Temperature...

Страница 285: ... IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 76 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build ProviderVersion Provider version generating the infor...

Страница 286: ...xists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example Port 1I Box 1 HWSerialNumber Enclosure Serial Number...

Страница 287: ...nerating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Warning Condition EventCategory 24 Primary Storage Cooling ProbableCause 51 Temperature Unacceptable ProbableCauseDescription Temperature Status Changed to Warning Condition NetworkAddresses A list of all the IP addresses IPv4 and I...

Страница 288: ...BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connec...

Страница 289: ...y ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Critical EventCategory 24 Primary Storage Cooling ProbableCause 5...

Страница 290: ...he VariableValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if on...

Страница 291: ...Smart Array RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan Status OK EventCategory 24 Primary Storage Cooling ProbableCause 1 Other ProbableCauseDescription Fan Status Changed to OK NetworkAddresses A list of all the...

Страница 292: ...eValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists S...

Страница 293: ...wn ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan St...

Страница 294: ...escription of failure Note In some cases the VariableValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one e...

Страница 295: ...HP Smart Array RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan status Error Event...

Страница 296: ...escription of failure Note In some cases the VariableValues property can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one e...

Страница 297: ...s provider Table 16 1 Overview Implemented Profiles HP FC HBA Profile 1 0 Requirements HBAAPI dll that supports the SNIA Common HBA API Version 2 18 Provider Installation Files Dll s HPWMISCSI dll HPWMISCSIEventMsg dll Cpqmdisk dll Cpqmscsi dll Cpqmsas dll Cpqstmsg dll Cpqstrutl dll HPWMISRV exe Hpwmistor exe MOF s HPFCA_Schema mof HPWMIFCA MOF HPWMIFCAErrorMetaData mof HPWMIFCARegistration mof HP...

Страница 298: ...FC HBA 298 Figure 16 1 Instance diagram for a single HBA with two controllers with one port on each controller ...

Страница 299: ...h port 16 2 2Discovering HBA topology and attributes To discover the HBA topology and attributes follow these steps 1 Get the instance of HPFCHBA_ComputerSystem on a managed system 2 Get all association instances of HPFCHBA_ComputerSystemPortController corresponding to the HPFCHBA_ComputerSystem 3 For each association of HPFCHBA_ComputerSystemPortController get the corresponding instance of HPFCHB...

Страница 300: ...BA_PortController get the corresponding association HPFCHBA_PortControllerFirmwareIdentityBIOS 11 For each instance of association HPFCHBA_PortControllerFirmwareIdentityBIOS get the corresponding instance of HPFCHBA_FirmwareIdentityBIOS The VersionString property contains the BIOS version Other properties of interest are Description ElementName and Manufacturer 12 For each instance of HPFCHBA_Port...

Страница 301: ...ributes 16 3Class implementations 16 3 1HPFCHBA_ComputerSystem HPFCHBA_ComputerSystem is used to identify classes that represent the all Fibre Channel ports Table 16 2 Class HPFCHBA_ComputerSystem Property name Property implementation CIM_ManagedElement ...

Страница 302: ...t CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_System CreationClassName HPFCHBA_ComputerSystem NameFormat Other CIM_ComputerSystem Dedicated 0 IdentifyingDescriptions 0 HPQ GUID OtherIdentifyingInfo 0 85408DBD 6A39 41CD 9E5A 357AEA130BBF 16 3 2HPFCHBA_FCPort HPFCHBA_FCPort is used to represent a Fibre Channel port device Tabl...

Страница 303: ...t EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName HPFCHBA_FCPort DeviceID nodeWWN portWWN where nodeWWN is the node WWN and portWWN is the port WWN SystemName HPQ GUID 85408DBD 6A39 41CD 9E5A 357AEA130BBF NODEWWN nodewwn PORTWWN portwwn where nodewwn is the node WWN and portwwn is the port WWN HPFCHBA_ComputerSystem System...

Страница 304: ...M_NetworkPort LinkTechnology 4 FC PermanentAddress PortWWN PortNumber Port number SupportedMaximumTransmissionUnit Port maximum frame size CIM_FCPort ActiveFC4Types Array of port active FC4 type bits SupportedFC4Types Array of port supported FC4 type bits 16 3 3HPFCHBA_PortController HPFCHBA_PortController is a logical device corresponding to a hardware network port controller Table 16 4 Class HPF...

Страница 305: ...PortStatistics represents statistics for a Fibre Channel port In the following table HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure This information comes directly for the HBA and is not altered Table 16 5 Class HPFCHBA_FCPortStatistics Property name Property implementation CIM_ManagedElement ElementName Product name CIM_StatisticalData InstanceID HPQ GUID 85408DBD...

Страница 306: ...t LossOfSyncCounter HBAAPI_PORTSTATISTICS LossOfSyncCount NOSCount HBAAPI_PORTSTATISTICS NOSCount PrimitiveSeqProtocolErrCount HBAAPI_PORTSTATISTICS PrimitiveSeqProtocolErrCoun t 16 3 5HPFCHBA_LogicalPortGroup A collection of one or more ports logically grouped for administrative and discovery and topology purposes Table 16 6 Class HPFCHBA_LogicalPortGroup Property name Property implementation CIM...

Страница 307: ... CreationClassName HPFCHBA_PhysicalPackage Manufacturer Manufacturer Model Model OtherIdentifyingInfo Location PCI Slot x where x is the PCI slot number SerialNumber Serial Number Tag HPQ GUID 85408DBD 6A39 41CD 9E5A 357AEA130BBF NODEWWN nodewwn PORTWWN portwwn where nodewwn is the node WWN and portwwn is the port WWN Version Board Version or N A when not available CIM_PhysicalPackage RemovalCondi...

Страница 308: ...BA_SoftwareIdentityDrv Table 16 9 Class HPFCHBA_SoftwareIdentityDrv Property name Property implementation CIM_ManagedElement Caption FC HBA Driver Model Description Device Drive Description ElementName FC HBA Driver CIM_ManagedSystemElement Name PortWWN CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FC HBA Driver Classifications 2 Driver InstanceID HPQ GUID 85408DBD 6A39 41CD 9...

Страница 309: ...e InstanceID HPQ GUID 85408DBD 6A39 41CD 9E5A 357AEA130BBF NODEWWN nodewwn PORTWWN portwwn HPFCHBA_FirmwareIdentityFW where nodewwn is the node WWN and portwwn is the port WWN Manufacturer Manufacturer SerialNumber Serial number VersionString Firmware version 16 3 10HPFCHBA_FirmwareIdentityBIOS HPFCHBA_FirmwareIdentityBIOS represents adapter BIOS associated with the Fibre Channel port controller T...

Страница 310: ...rsion as reported by HBA TargetTypes HBA BIOS UNKNOWN SerialNumber Serial Number MajorVersion 0 MinorVersion 0 RevisionNumber 0 HP_SoftwareIdentity 16 3 11HPFCHBA_SCSIProtocolController HPFCHBA_SCSIProtocolController represents a protocol controller that manages a SCSI interface This class is used for backward compatibility with SMI S 1 0 Table 16 12 Class HPFCHBA_SCSIProtocolController Property n...

Страница 311: ..._SCSIProtocolEndpoint HPFCHBA_SCSIProtocolEndpoint represents SCSI protocol running through a port Table 16 13 Class HPFCHBA_SCSIProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName SCSI Protocol Endpoint CIM_ManagedSystemElement Name PortWWN CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled RequestedState 12 Not Applicable CIM_ServiceAccessPoin...

Страница 312: ...nagedElement Caption FC HBA Consolidated Status Description A consolidated OperationalStatus for all FCHBA_ComputerSystem instances ElementName FC HBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID HPQ GUID 85408DBD 6A39 41CD 9E5A 357AEA130BBF HPFCHBA_GroupSystemSpecificColle ction HP_GroupSystemSpecificCollection 0 Unknown GroupOperationalStatus 0 1 Other 2 OK 3 Degrad...

Страница 313: ...rty implementation CIM_Component CIM_SystemDevice HPFCHBA_ComputerSystemPortController GroupComponent ref HPFCHBA_ComputerSystem PartComponent ref HPFCHBA_PortController 16 3 16HPFCHBA_ComputerSystemSCSIProtocolController HPFCHBA_ComputerSystemSCSIProtocolController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SCSIProtocolController Table 16 17 Class HPFCHBA_Compu...

Страница 314: ...t an association between HPFCHBA_ComputerSystem and HPFCHBA_SoftwareIdentityDrv Table 16 19 Class HPFCHBA_ComputerSystemSoftwareIdentityDrv Property name Property implementation CIM_Component CIM_SystemDevice HPFCHBA_ComputerSystemSoftwareIdentityDrv InstalledSoftware ref HPFCHBA_SoftwareIdentityDrv System ref HPFCHBA_ComputerSystem 16 3 19HPFCHBA_SystemServiceAccessPoint HPFCHBA_SystemServiceAcce...

Страница 315: ...HPFCHBA_FcPortStatistics 16 3 21HPFCHBA_FCPortLogicalPortGroup HPFCHBA_FCPortLogicalPortGroup is used to represent an association between HPFCHBA_FCPort and HPFCHBA_LogicalPortGroup Table 16 22 Class HPFCHBA_FCPortLogicalPortGroup Property name Property implementation CIM_MemberOfCollection HPFCHBA_FCPortLogicalPortGroup Collection ref HPFCHBA_LogicalPortGroup Member ref HPFCHBA_FCPort 16 3 22HPFC...

Страница 316: ...olControllerForDevice CIM_ProtocolControllerForPort HPFCHBA_SCSIProtocolControllerFCPort Antecedent ref HPFCHBA_SCSIProtocolController Dependent ref HPFCHBA_FCPort 16 3 24HPFCHBA_PortControllerFCPort HPFCHBA_PortControllerFCPort is used to represent an association between HPFCHBA_PortController and HPFCHBA_FCPort Table 16 25 Class HPFCHBA_PortControllerFCPort Property name Property implementation ...

Страница 317: ...Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity HPFCHBA_SoftwareIdentityDrvPortController Antecedent ref HPFCHBA_SoftwareIdentityDrv Dependent ref HPFCHBA_PortController 16 3 27HPFCHBA_PortControllerFirmwareIdentityFW HPFCHBA_PortControllerFirmwareIdentityFW is used to represent an association between HPFCHBA_PortController and HPFCHBA_FirmwareIdentityFW Table 16 2...

Страница 318: ...is used to represent an association between HPFCHBA_Product and HPFCHBA_PhysicalPackage Table 16 30 Class HPFCHBA_ProductPhysicalComponent Property name Property implementation CIM_Component CIM_ProductPhysicalComponent HPFCHBA_ProductPhysicalComponent GroupComponent ref HPFCHBA_Product PartComponent ref HPFCHBA_PhysicalPackage 16 3 30HPFCHBA_SystemPackaging HPFCHBA_SystemPackaging is used to repr...

Страница 319: ...ystem and HPFCHBA_GroupSystemSpecificCollection Table 16 33 Class HPFCHBA_GroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HPFCHBA_GroupHostedCollection Antecedent ref CIM_ComputerSystem Dependent ref HPFCHBA_GroupSystemSpecificCollection 16 3 33HPFCHBA_FCPortGroupSystemSpecific HPFCHBA_FCPortGroupSystemSp...

Страница 320: ...alPosition Location PCI Slot x where x is the PCI slot number 16 3 35HPFCHBA_PhysicalElementLocation HPFCHBA_PhysicalElementLocation is used to represent an association between the HPFCHBA_PhysicalPackage and HPFCHBA_Location Table 16 36 Class HPFCHBA_PhysicalElementLocation Property name Property implementation CIM_ElementLocation HPFCHBA_PhysicalElementLocation Element ref HPFCHBA_PhysicalPackag...

Страница 321: ...n is recommended SystemName HP_ComputerSystem SystemName SystemCreationClassName HP_ComputerSystem CreationClassName HP_AlertIndication Summary FC HBA port OK EventCategory 11 I O Adapter ProbableCause 1 Other ProbableCauseDescription FC HBA Port Status Changed to OK NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 200...

Страница 322: ...ironment BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated RackName Rack name if one exists RackUID Rack Unique Identifier if one exists HWFirmwareVersion Controller...

Страница 323: ...ssName HP_AlertIndication Summary FC HBA port state Unknown EventCategory 11 I O Adapter ProbableCause 5 Connection Establishment Error ProbableCauseDescription FC HBA Port State Changed to Link Down NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 77 Windows Server 2008...

Страница 324: ... property containing the virtual system UUID when running in a Virtual Connect environment BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated RackName Rack name if on...

Страница 325: ...gistration mof HPWMISASErrorMetaData mof 17 2Use cases For specific use cases see HP SAS HBA Profile P00122 This provider implements a read only version of the profiles referenced No configuration functionality is supported by this provider This is in accordance with the SNIA profiles since HP does not advertise and ConfigurationService type classes 17 3Class implementations The following sections...

Страница 326: ...Default 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_System CreationClassName HPSAS_ArraySystem Name Controller Serial Number NameFormat Other CIM_ComputerSystem Dedicated 0 3 Storage Dedicated Dedicated 1 15 Block Server IdentifyingDescriptions Other Vendor Specific Name OtherIdentifyingInfo Controller Serial Number 17 3 2HPSAS_ArrayController HPSAS_ArrayController...

Страница 327: ... IdentifyingDescriptions Other Vendor Specific Name OtherIdentifyingInfo Controller Serial Number 17 3 3HPSAS_StorageVolume HPSAS_StorageVolume represents the Logical Volumes configured on the SAS HBA Table 17 4 Class HPSAS_StorageVolume CIM_ StorageVolume Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description For example Logical Volume 1 RA...

Страница 328: ...o a value of 0 ExtentStatus 0 This will indicate extended status for the volume 2 None 11 Rebuild Volume is currently rebuilding data IsBasedOnUnderlyingRedundancy False True RAID 1 or above NoSinglePointOfFailure False RAID 0 NumberOfBlocks Total Number of blocks on the volume 0 RAID 0 PackageRedundancy 1 RAID 1 True Primordial False Provider always sets this value to False CIM_Storagevolume Name...

Страница 329: ...icalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName HPSAS_DiskDrive DeviceID Opaque value SystemCreationClassName HPSAS_ArraySystem SystemName HPSAS_ArraySystem Name CIM_MediaAccessDevice CIM_DiskDrive HPSAS_DiskDrive DriveConfiguration See HP SAS HBA Profile DriveHasMNPData See HP SAS HBA Profile DriveInterface Se...

Страница 330: ...Element Name Serial number of drive OperationalStatus 0 Operational Status for the disk drive 0 Unknown 2 OK 5 Predictive Failure 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName HPSAS_StorageExtent DeviceID Opaque ID SystemCreationClassName HPSAS_ArraySystem SystemName H...

Страница 331: ... HPSAS_DiskDriveFirmware CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions 0 Disk Drive Firmware Classifications 0 10 Firmware InstanceID Opaque key Manufacturer Disk...

Страница 332: ...alPackage Manufacturer Controller vendor string Model Controller model string PartNumber N A Not Available for this implementation SerialNumber Controller Serial Number Tag HBA Serial number CIM_PhysicalPackage RemovalConditions 2 Not Applicable HPSAS_PhysicalPackage 17 3 8HPSAS_DiskPhysicalPackage HPSAS_DiskPhysicalPackage represents the physical aspects of the disk drive There is one instance pe...

Страница 333: ...ble HotSwappable FALSE Drive is not hot swappable 0 Unknown RemovalConditions 2 Not Applicable 3 Removable when off 4 Removable when on or off HPSAS_DiskPhysicalPackage 17 3 9HPSAS_PortController HPSAS_PortController represent the HBA in the host system There is one instance per HBA Table 17 10 Class HPSAS_PortController CIM_PortController Property name Property implementation CIM_ManagedElement E...

Страница 334: ...that the array controller is attached to a local bus on the host for example PCI Table 17 11 Class HPSAS_DAPort CIM_DAPort Property name Property implementation CIM_ManagedElement ElementName Controller name and location for example HP 8 INT Port SAS SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus 0 Port status 0 Unknown 2 OK 6 Error CIM_LogicalElement CIM_EnabledLogicalElement Enabl...

Страница 335: ...FW UNKNOWN CIM_ManagedSystemElement Name HBA Firmware CIM_LogicalElement Caption HBA Firmware Description HBA Firmware CIM_SoftwareIdentity ClassificationDescriptions 0 HBA Firmware Classifications 0 10 Firmware InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType CIM SoftwareFamily IdentityInfoValue HPQ TargetType value Set to HPQ HBA FW UNKNOWN VersionString Controller fi...

Страница 336: ...lated by summing the total space on all raid drives connected to this controller HPSAS_PrimordialPool 17 3 13HPSAS_PrimordialPoolNoRaid HPSAS_PrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes Table 17 14 Class HPSAS_PrimordialPoolNoRaid CIM_StoragePool Property name Property implementation CIM_ManagedElement ElementName Contr...

Страница 337: ...ool CIM_StoragePool Property name Property implementation CIM_ManagedElement ElementName Controller name and location pool identifier For example HP 8 INT Port SAS SATA HBA in Slot 3 Storage Pool CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number 1 Primordial FALSE RemainingManagedSpace 0 TotalManagedSpace Total raw space managed by th...

Страница 338: ...vationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 FALSE RAID 0 NoSinglePointOfFailure TRUE RAID 1 0 RAID 0 PackageRedundancyGoal 1 RAID 1 0 RAID 0 PackageRedundancyMax 1 RAID 1 0 RAID 0 PackageRedundancyMin 1 RAID 1 HPSAS_StorageSetting 17 3 16HPSAS_SCSIProtocolEndpoint HPSAS_SCSIProtocolEndpoint represents an access point to storage resources Table 17 17 Class HPSAS_SCSIProtocolEndpoint CI...

Страница 339: ...SCSIProtocolEndpoint ConnectionType 1 Other OtherConnectionType PCI Role 4 Both Initiator and Target HPSAS_SCSIProtocolEndpoint 17 3 17HPSAS_SCSIProtocolController HPSAS_SCSIProtocolController represents a view a SCSI resources on the controller Table 17 18 Class HPSAS_SCSIProtocolController CIM_SCSIProtocolController Property name Property implementation CIM_ManagedElement ElementName Controller ...

Страница 340: ...17 3 18HPSAS_StorageRedundancySet HPSAS_StorageRedundancySet represents disk sparing aspect of a RAID configuration There is an instance for every raid set that has spare drives configured Table 17 19 Class HPSAS_StorageRedundancySet CIM_StorageRedundancySet Property name Property implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection Insta...

Страница 341: ...GroupOperationalStatus Consolidated status for all array controllers See the HP SAS HBA profile for details on how this is calculated GroupStatusDescriptions Description of GroupOperationalStatus HPSAS_ StorageSpecificCollection 17 3 20HPSAS_ArraySystemLocation HPSAS_ArraySystemLocation represents a location string for the HBA Table 17 21 Class HPSAS_ArraySystemLocation HP_Location Property name P...

Страница 342: ...S_DiskDriveLocation HP_Location Property name Property implementation CIM_ManagedElement Caption Disk location For example Bay 5 Description Disk location For example Bay 5 ElementName Disk location For example Bay 5 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk ElementLocationTagDesc 20 Bay HPSAS_DiskDriveLocation 17 3 22HPSAS_StorageCa...

Страница 343: ...ax 1 When number of drives 1 2 When number of drives 1 For example Pool can be configured for redundancy 0 When Pool is NonRAID DataRedundancyMin 1 No single point of failure RAID DeltaReservationDefault 0 DeltaReservationMax 0 DeltaReservationMin 0 ElementType 5 Storage Pool True When number of drives 1 For example Pool can be configured for redundancy NoSinglePointOfFailure False When number of ...

Страница 344: ...ive cage assembly and back plane within a storage enclosure There can be multiple instances within a duplexed enclosure Table 17 25 Class HPSAS_DriveCage CIM_PhysicalPackage Property name Property implementation CIM_ManagedElement ElementName Port m Box n where m is the name of the port to which this drive cage is connected and n is the Box Number For example Port IE Box 1 CIM_ManagedSystemElement...

Страница 345: ... 17 26 Class HPSAS_EnclosureFirmware CIM_SoftwareIdentity Property name Property Implemenation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Storage Enclosure Firmware CIM_LogicalElement Caption Storage Enclosure Firmware Description Storage Enclosure Firmware CIM_SoftwareIdentity ClassificationDescriptions 0 Storage Enclosure Firmware Classifications 0 10 Firmware ...

Страница 346: ...lable Model Enclosure model string MSA50 10D25G1 N A if not available PartNumber N A Not Available in this implementation SerialNumber Enclosure Serial Number N A is reported if there is no serial number for example internal enclosures Tag Opaque key Version N A Not Available in this implementation CIM_PhysicalPackage RemovalConditions 2 Not Applicable CIM_PhysicalFrame CIM_Chassis HP_StorageEnclo...

Страница 347: ...1 Fan status See Profile Index 2 Power Supply status See Profile Index 3 Temp Sensor Status See Profile CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_System CreationClassName HPSAS_StorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated 0 2 Other IdentifyingDescriptions 0 Othe...

Страница 348: ...ElementLocationTagDesc 19 Box 17 3 29HPSAS_DriveCageDiskDrive Association Table 17 30 Class HPSAS_DriveCageDiskDrive CIM_Container Property name Property implementation GroupComponent HPSAS_DriveCage PartComponent HPSAS_DiskPhysicalPackage 17 3 30HPSAS_StorageEnclosureDriveCage Association Table 17 31 Class HPSAS_StorageEnclosureDriveCage CIM_Container Property name Property implementation GroupCo...

Страница 349: ...3HPSAS_StorageEnclosureProcessorEnclosureFirmware Association Table 17 34 Class HPSAS_StorageEnclosureProcessorEnclosureFirmware CIM_ElementSoftwareIdentity Property name Property implementation Antecedent HPSAS_EnclosureFirmware Dependent HPSAS_StorageEnclosureProcessor ElementSoftwareStatus 0 2 Current ElementSoftwareStatus ElementSoftwareStatus 1 6 Installed 17 3 34HPSAS_StorageEnclosureStorage...

Страница 350: ...SAS_StorageCapabilities ManagedElement HPSAS_PrimordialPool 17 3 37HPSAS_PrimordialPoolNoRaidStorageCapabilities Association Table 17 38 Class HPSAS_PrimordialPoolNoRaidStorageCapabilities CIM_ElementCapabilities Property name Property implementation Capabilities HPSAS_StorageCapabilities ManagedElement HPSAS_PrimordialPoolNoRaid 17 3 38HPSAS_StoragePoolStorageCapabilities Association Table 17 39 ...

Страница 351: ..._ArraySystemDiskDrive Association Table 17 42 Class HPSAS_ArraySystemDiskDrive CIM_SystemDevice Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_DiskDrive 17 3 42HPSAS_ArraySystemStorageVolume Association Table 17 43 Class HPSAS_ArraySystemStorageVolume CIM_SystemDevice Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HP...

Страница 352: ...Component HPSAS_ArraySystem PartComponent HPSAS_PrimordialPool 17 3 46HPSAS_ArraySystemPrimordialPoolNoRaid Association Table 17 47 Class HPSAS_ArraySystemPrimordialPoolNoRaid CIM_HostedStoragePool Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_PrimordialPoolNoRaid 17 3 47HPSAS_ArraySystemStoragePool Association Table 17 48 Class HPSAS_ArraySystemStorage...

Страница 353: ...sociation Table 17 51 Class HPSAS_ProductPhysicalPackage CIM_ProductPhysicalPackage Property name Property implementation GroupComponent HPSAS_Product PartComponent HPSAS_PhysicalPackage 17 3 51HPSAS_StoragePoolStorageExtent Association Table 17 52 Class HPSAS_StoragePoolStorageExtent CIM_ConcreteComponent Property name Property implementation GroupComponent HPSAS_StoragePool PartComponent HPSAS_S...

Страница 354: ...m CIM_MemberOfCollection Property name Property implementation Collection HPSAS_StorageSpecificCollection Member HPSAS_ArraySystem 17 3 55HPSAS_StorageRedundancySetStorageExtent Association Table 17 56 Class HPSAS_StorageRedundancySetStorageExtent CIM_MemberOfCollection Property name Property implementation Collection HPSAS_StorageRedundancySet Member HPSAS_StorageExtent 17 3 56HPSAS_ArraySystemFi...

Страница 355: ...ementation Antecedent HPSAS_Firmware Dependent HPSAS_ArraySystem ElementSoftwareStatus 0 2 Current ElementSoftwareStatus ElementSoftwareStatus 1 6 Installed 17 3 59HPSAS_DiskDriveDiskDriveFirmware Association Table 17 60 Class HPSAS_DiskDriveDiskDriveFirmware CIM_ElementSoftwareIdentity Property name Property implementation Antecedent HPSAS_DiskDriveFirmware Dependent HPSAS_DiskDrive ElementSoftwa...

Страница 356: ...oolStoragePool Association Table 17 63 Class HPSAS_PrimordialPoolStoragePool CIM_AllocatedFromStoragePool Property name Property implementation Antecedent HPSAS_PrimordialPool Dependent HPSAS_StoragePool SpaceConsumed Bytes consumed by storage pool 17 3 63HPSAS_SpareExtentStorageRedundancySet Association Table 17 64 Class HPSAS_SpareExtentStorageRedundancySet CIM_IsSpare Property name Property imp...

Страница 357: ...on Association Table 17 67 Class HPSAS_StorageGroupHostedCollection HP_GroupHostedCollection Property name Property implementation Antecedent HP_ComputerSystem Dependent HPSAS_StorageSpecificCollection 17 3 67HPSAS_PhysicalPackageArraySystem Association Table 17 68 Class HPSAS_PhysicalPackageArraySystem CIM_ComputerSystemPackage Property name Property implementation Antecedent HPSAS_PhysicalPackag...

Страница 358: ...HPSAS_SCSIProtocolEndpointSCSIProtocolController Association Table 17 71 Class HPSAS_SCSIProtocolEndpointSCSIProtocolController CIM_SAPAvailableForElement Property name Property implementation AvailableSAP HPSAS_SCSIProtocolEndpoint ManagedElement HPSAS_SCSIProtocolController 17 4Supported indications 17 4 1SAS HBA Status OK Table 17 72 HPSAS_DeviceIndication SAS HBA status OK Property name Proper...

Страница 359: ...sion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 77 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion The operating system version ...

Страница 360: ...UUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string HWLogicalLocation Controller Location string For example Slot 3 HWManufacturer Controller Manufacturer string HWSerialNumber Controller Serial Number HP_DeviceIndication DeviceModel Controller Model string 17 4 2SAS HB...

Страница 361: ...he indication in the form major minor revision build NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 77 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion The operating system version of the computer system generating ...

Страница 362: ... Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string HWLogicalLocation Controller Location string For example Slot 3 HWManufacturer Controller Manufacturer string HWSerialNumber Controller Serial Number HP_DeviceIndication DeviceModel Controller Model string 17 4 3Physical D...

Страница 363: ...ajor minor revision build NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 77 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion The operating system version of the computer system generating the indication in the forma...

Страница 364: ...k name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string H...

Страница 365: ...al drive status Error EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription Physical Drive Status Changed to Error ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSTy...

Страница 366: ...closureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication...

Страница 367: ...ng the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive rebuilding EventCategory 6 Primary Storage ProbableCause 1 Other ProbableCauseDescription Physical Drive Rebuilding ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of...

Страница 368: ... 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial numbe...

Страница 369: ...void loss of data SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive predictive failure EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription Physical Drive Predictive Failure ProviderVersion Provider version generating ...

Страница 370: ...re for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property...

Страница 371: ...ter system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical Drive status OK EventCategory 6 Primary Storage ProbableCause 1 Other ProbableCauseDescription Logical Drive Status Changed to OK ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAd...

Страница 372: ... EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 17 4 8Logical Driv...

Страница 373: ...esses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 77 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion The operating system version of the computer system generating the indication in the following format major minor build SystemFirmwareVersion Firmware version of the c...

Страница 374: ...ementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 3 Warning IndicationTime Time of indication CIM_AlertIndication Description A logical drive is in a degraded state Device is still servicing I O but redundancy may be degraded or lost AlertingMangedElement WBEM Path of Storage Volume AlertingElementFormat 2 CIMObjectPath AlertType 5 Dev...

Страница 375: ...Version Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Clas...

Страница 376: ...ecommendedActions Check status of all enclosure power supplies Ensure that power supplies have not failed Add or replace power supplies as necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Power Supply status Non Redundant EventCategory 17 Primary Storage P...

Страница 377: ... String VariableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack n...

Страница 378: ...f the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Redundant power supply status OK EventCategory 17 Primary Storage Power ProbableCause 1 Other ProbableCauseDescrip...

Страница 379: ...String VariableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack na...

Страница 380: ...erName HP SAS RecommendedActions Check status of all enclosure power supplies Ensure that power supplies have not failed Add or replace power supplies as necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Power supply status Redundant Degraded EventCategory ...

Страница 381: ...ring VariableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name...

Страница 382: ... SAS RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status OK EventCategory 24 Primary Storage Cooling ProbableCause 1 Other ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses C...

Страница 383: ...riableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists Syste...

Страница 384: ...the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating t...

Страница 385: ...ableNames FailureDescription VariableTypes 1 String VariableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureN...

Страница 386: ... Alert EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassNam...

Страница 387: ...ableNames FailureDescription VariableTypes 1 String VariableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureN...

Страница 388: ...RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan status OK EventCategory 24 Primary Storage Cooling ProbableCause 1 Other ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP...

Страница 389: ...alues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtua...

Страница 390: ...e unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan sta...

Страница 391: ...ableValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one e...

Страница 392: ...ndication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated Check for proper room temperature and internal external airflow Add or repair fans and air baffling if necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndi...

Страница 393: ...bleValues Short Description of failure In some cases VariableValues can be N A or null 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one ex...

Страница 394: ...sg dll Cpqstrutl dll HPWMISRV exe Hpwmistor exe HPWmiScsi mof HPWmiSCSIErrorMetaData mof HPWMISCSIEvent mof HPWMISCSIRegistration mof 18 2Use cases For use cases see HP SCSI HBA Profile P00123 18 3Class implementations The following sections define the supported properties for the SCSI HBA provider For details of each property see the HP SCSI HBA Profile P00123 and associated MOF files 18 3 1HPSCS...

Страница 395: ...em CreationClassName Key HPSCSI_HBAComputerSystem Name Key HBA index NameFormat Other CIM_ComputerSystem Dedicated 0 Not Dedicated OtherDedicatedDescriptions Direct Attached Storage HBA StatusDescriptions More information for OperationalStatus result s HPSCSI_HBAComputerSystem ControllerStatus See HP SCSI HBA Profile 18 3 2HPSCSI_StorageVolume HPSCSI_StorageVolume represents the volumes exposed to...

Страница 396: ...SCSI_HBAComputerSystem SystemName HBA index CIM_StorageExtent BlockSize Block Size in bytes ConsumableBlocks Total Number of blocks on volume DataRedundancy 1 DeltaReservation 0 ExtentStatus 0 2 None IsBasedOnUnderlyingRedundancy False NoSinglePointOfFailure False NumberOfBlocks Total Number of blocks on volume PackageRedundancy 0 PercentComplete 0 Deleteable FALSE StatusDescriptions Description o...

Страница 397: ...edSystemElement Name Disk Serial Number 0 Other OperationalStatus 0 2 OK 5 Predictive Failure 6 ERROR StatusDescriptions Description of the Operational Status the reason why OperationalStatus is set CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedState 12 Not Applicable CIM_LogicalDevice CreationClassName HPSCSI_DiskDrive DeviceID Opaque...

Страница 398: ...sk 18 3 4HPSCSI_StorageExtent HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive There is one instance per disk drive Table 18 5 Class HPSCSI_StorageExtent CIM_StorageExtent Property name Property implementation CIM_ManagedElement ElementName Disk name for example SCSIBUS 1 SCSIID 0 CIM_ManagedSystemElement Name Serial number of drive 0 Other OperationalStatus...

Страница 399: ...instance per disk drive Table 18 6 Class HPSCSI_DiskDriveFirmwareIdentity CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement ElementName TargetType value drive model string CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions 0 Disk Drive Firmware Classifications 0 10 Firmware Description Disk Drive Firmware...

Страница 400: ...ot Applicable SerialNumber HBA serial number Tag Opaque ID Version N A Not available in this implementation 18 3 7HPSCSI_DiskPhysicalPackage HPSCSI_DiskPhysicalPackage represents the physical aspects of the disk drive There is one instance per disk drive Table 18 8 Class HPSCSI_DiskPhysicalPackage CIM_PhysicalPackage Property name Property implementation CIM_ManagedElement ElementName Disk locatio...

Страница 401: ...for an internal or externally attached enclosure Table 18 9 Class HPSCSI_StorageEnclosure CIM_Chassis Property name Property implementation RemovalConditions 2 Not Applicable CIM_ManagedElement ElementName Enclosure location for example Internal Storage System CIM_ManagedSystemElement Name Enclosure index CIM_PhysicalElement CreationClassName HPSCSI_StorageEnclosure Manufacturer Enclosure vendor s...

Страница 402: ...ocation for example Internal Storage System CIM_ManagedSystemElement OperationalStatus Operational status for enclosure and associated power supplies fans and sensors The use of OperationalStatus is described in the HP Storage Enclosure Profile Index values are populated as follows OperationalStatus 0 Enclosure status 0 Unknown 2 OK 3 Degraded 6 Error OperationalStatus 1 Fan status See Profile Ope...

Страница 403: ...lement ElementName Controller name and location for example SCSI Controller Port 1 in Slot 4 Name Controller model name CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not applicable RequestedState 12 Not applicable CIM_LogicalDevice CreationClassName HPSCSI_HBAPortController DeviceID Key HBA index SystemCreationClassName HPSCSI_HBAComp...

Страница 404: ...perationalStatus 0 Port status 0 Unknown 2 OK 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not applicable RequestedState 12 Not applicable CIM_LogicalDevice CreationClassName HPSCSI_DAPort DeviceID Opaque key SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA Index CIM_LogicalPort UsageRestriction 2 Front End Only CIM_DAPort PortType 82 ...

Страница 405: ... Enabled EnabledState 5 Not applicable RequestedState 12 Not applicable CIM_LogicalDevice CreationClassName HPSCSI_HBASPIPort DeviceID Opaque key SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA Index CIM_LogicalPort PortType 140 Parallel SCSI UsageRestriction 3 Back end Only CIM_SPIPort MaxDataWidth Max bus width bits MaxTransferRate Max rate in bits per second 18 3 13HPSCSI_HBAFir...

Страница 406: ...ntityInfoValue HPQ TargetType value VersionString Controller firmware version string IsEntity FALSE Always set to FALSE 18 3 14HPSCSI_EnclosureFirmware HPSCSI_EnclosureFirmware represents the firmware installed on a SCSI HBA enclosure Table 18 15 Class HPSCSI_EnclosureFirmware CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement Caption Storage Enclosure Firmware ElementNa...

Страница 407: ...for example SCSIBUS 1 SCSIID 0 CIM_StatisticalData InstanceID Opaque key SampleInterval 0 CIM_MediaAccessStatData HPSCSI_MediaAccessStatData ECCRecoveredReadErrors See HP SCSI HBA Profile P00123 RetryRecoveredReadErrors See HP SCSI HBA Profile P00123 RetryRecoveredWriteErrors See HP SCSI HBA Profile P00123 HardReadErrors See HP SCSI HBA Profile P00123 HardWriteErrors See HP SCSI HBA Profile P00123...

Страница 408: ..._PhysicalPackage 0 Unknown RemovalConditions 2 Not Applicable 3 Removable when off 4 Removable when on or off HP_DriveCage DriveBays See HP Storage Enclosure profile DuplexLocation See HP Storage Enclosure profile 0 Unknown BackplaneSpeed 2 Ultra 3 3 Ultra 320 18 3 17HPSCSI_HBASCSIProtocolEndpoint HPSCSI_HBASCSIProtocolEndpoint represents an access point to storage resources for the HBA Table 18 1...

Страница 409: ...Both Initiator and Target 18 3 18HPSCSI_DASCSIProtocolEndpoint HPSCSI_DASCSIProtocolEndpoint represents an access point to storage resources for the host Table 18 19 Class HPSCSI_DASCSIProtocolEndpoint CIM_SCSIProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName Controller name and location for example SCSI Controller Port 1 in Slot 4 CIM_ManagedSystemElement CIM_L...

Страница 410: ...rotocolController CIM_SCSIProtocolController Property name Property implementation CIM_ManagedElement ElementName Controller name and location for example SCSI Controller Port 1 in Slot 4 CIM_ManagedSystemElement OperationalStatus 0 Operational status of the controller 0 Unknown 2 OK 6 Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable Request...

Страница 411: ...roupSystemSpecificCollection GroupOperationalStatus Consolidated status for all SCSI HBAs 0 Other 2 OK 3 Degraded 6 ERROR GroupStatusDescriptions Description of GroupOperationalStatus 18 3 21HPSCSI_StorageEnclosureLocation HPSCSI_StorageEnclosureLocation represents a location string for the enclosure Table 18 22 Class HPSCSI_StorageEnclsoureLocation HP_Location Property name Property implementatio...

Страница 412: ...SCSI Port 1 Name Key PhysicalPosition Key ElementLocationTag Duplex Top Duplex Bottom Non Duplex ElementLocationTagDesc 22 Drive Cage LocationInformation 0 HBA Port identifier Examples SCSI Port 1 SCSI Port 2 LocationInfoDesc 0 0 Hood Tag 18 3 23HPSCSI_HBALocation HPSCSI_HBALocation represents a location string for the HBA Table 18 24 Class HPSCSI_HBALocation HP_Location Property name Property imp...

Страница 413: ...ame Property implementation ElementName Disk name for example SCSIBUS 1 SCSIID 0 Caption Disk name For example SCSIBUS 1 SCSIID 0 Description Disk name For example SCSIBUS 1 SCSIID 0 Name Key PhysicalPosition Key ElementLocationTag Drive SCSI ID ElementLocationTagDesc 0 Hood Tag 18 3 25HPSCSI_HBAProduct HPSCSI_HBAProduct represents the top level marketing information for the SCSI HBA Table 18 26 C...

Страница 414: ... name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_HBASCSIProtocolController 18 3 28HPSCSI_HBAComputerSystemPortController Association Table 18 29 Class HPSCSI_HBAComputerSystemPortController CIM_Logicalidentity Property name Property implementation SameElement HPSCSI_HBAComputerSystem SystemElement HPSCSI_HBAPortController 18 3 29HPSCSI_HBAComputerSystemDis...

Страница 415: ...PSCSI_HBAComputerSystemSPIPort Association Table 18 33 Class HPSCSI_HBAComputerSystemSPIPort CIM_SystemDevice Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_HBASPIPort 18 3 33HPSCSI_HBAComputerSystemDAPort Association Table 18 34 Class HPSCSI_HBAComputerSystemDAPort CIM_SystemDevice Property name Property implementation GroupComponent HPSCSI_HBAC...

Страница 416: ...operty implementation GroupComponent HPSCSI_HBAProduct PartComponent HPSCSI_HBAPhysicalPackage 18 3 37HPSCSI_StorageEnclosureDriveCage Association Table 18 38 Class HPSCSI_StorageEnclosureDriveCage CIM_Container Property name Property implementation GroupComponent HPSCSI_StorageEnclosure PartComponent HPSCSI_DriveCage 18 3 38HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackag e Association Table 18 3...

Страница 417: ...reStatus 1 6 Installed 18 3 41HPSCSI_SCSIProtocolControllerStorageVolume Association Table 18 42 Class HPSCSI_SCSIProtocolControllerStorageVolume CIM_ProtocolControllerForUnit Property name Property implementation Antecedent HPSCSI_HBASCSIProtocolController Dependent HPSCSI_StorageVolume DeviceAccess 2 Read Write DeviceNumber Device LUN number 18 3 42HPSCSI_StorageEnclosureProcessorEnclosureFirmwa...

Страница 418: ..._DiskDriveStorageExtent CIM_MediaPresent Property name Property implementation Antecedent HPSCSI_DiskDrive Dependent HPSCSI_StorageExtent 18 3 45HPSCSI_DiskPhysicalPackageDiskDrive Association Table 18 46 Class HPSCSI_DiskPhysicalPackageDiskDrive CIM_Realizes Property name Property implementation Antecedent HPSCSI_DiskPhysicalPackage Dependent HPSCSI_DiskDrive 18 3 46HPSCSI_StorageExtentStorageVol...

Страница 419: ... 49HPSCSI_HBAGroupCollectionComputerSystem Association Table 18 50 Class HPSCSI_HBAGroupCollectionComputerSystem HP_GroupHostedCollection Property name Property implementation Antecedent HP_WinComputerSystem Dependent HPSCSI_HBAGroupCollection 18 3 50HPSCSI_HBAGroupCollectionHBAComputerSystem Association Table 18 51 Class HPSCSI_HBAGroupCollectionHBAComputerSystem CIM_MemberOfCollection Property n...

Страница 420: ...essStatData Association Table 18 54 Class HPSCSI_DiskDriveMediaAccessStatData CIM_ElementStatisticalData Property name Property implementation ManagedElement HPSCSI_DiskDrive Stats HPSCSI_MediaAccessStatData 18 3 54HPSCSI_HBAPhysicalPackageLocation Association Table 18 55 Class HPSCSI_HBAPhysicalPackageLocation CIM_PhysicalElementLocation Property name Property implementation Element HPSCSI_HBAPhy...

Страница 421: ... HPSCSI_DiskPhysicalPackageDiskDriveLocation CIM_PhysicalElementLocation Property name Property implementation Element HPSCSI_DiskPhysicalPackage PhysicalLocation HPSCSI_DiskDriveLocation 18 3 58HPSCSI_SCSIProtocolEndpointSCSIProtocolController Association Table 18 59 Class HPSCSI_SCSIProtocolEndpointSCSIProtocolController CIM_SAPAvailableForElement Property name Property implementation AvailableS...

Страница 422: ...cation PerceivedSeverity 2 Information IndicationTime Time of indication CIM_AlertIndication Description A SCSI physical drive status has changed from non OK to OK AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 4 EventTime Time of the event or time of the indication if event time unknown ProviderName HP ...

Страница 423: ...m generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with a...

Страница 424: ...ror AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 5 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Check for failed or removed physical drives SystemName Name of the computer system generating the indication SystemCreationClassName Cre...

Страница 425: ... Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Uniqu...

Страница 426: ...Actions Replace drive immediately to avoid loss of data SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary SCSI physical drive predictive failure EventCategory 6 Primary Storage ProbableCause 86 Disk Failure ProbableCauseDescription SCSI Physical Drive Predictive Fail...

Страница 427: ...ed with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEnclosureCS Name RackName Rack name if one exists RackUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional prop...

Страница 428: ...the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary The physical drive is offline EventCategory 6 Primary Storage ProbableCause 72 Element unavailable ProbableCauseDescription Physical Drive Offline ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses A lis...

Страница 429: ...ckUID Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk L...

Страница 430: ... missing was OK EventCategory 6 Primary Storage ProbableCause 73 Element Missing ProbableCauseDescription Missing Physical Drive was OK ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server ...

Страница 431: ...rtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string 18 4 6Physical Drive S...

Страница 432: ...Drive was Error ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 76 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating s...

Страница 433: ...al system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string 18 4 7Physical Drive Status Missing was Predictive Failure Table 18 68 HPSCSI_DeviceIndication Physical Dri...

Страница 434: ...inor revision build NetworkAddresses A list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows Server 2003 32 bit OSType 70 Windows Server 2003 64 bit 76 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build...

Страница 435: ...k firmware version string HWLogicalLocation Disk Location string HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string 18 4 8Physical Drive Status Missing was OFFLINE Table 18 69 HPSCSI_DeviceIndication Physical Drive status Missing was OFFLINE Property name Property implementation CIM_Indication IndicationIdentifier GUID string...

Страница 436: ...ype 70 Windows Server 2003 64 bit 76 Windows Server 2008 32 bit 77 Windows Server 2008 64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indi...

Страница 437: ...odel Disk Model string 18 4 9Controller Status Changed to Unknown Table 18 70 HPSCSI_DeviceIndication Controller status changed to Unknown Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at time of indication PerceivedSeverity 0 unknown IndicationTime Time of indication CIM_AlertIndication Description A SCSI device status has changed to Unknown Alert...

Страница 438: ...64 bit 103 Windows Server 2008 R2 OSVersion Operating system version of the computer system generating the indication in the format major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication Syst...

Страница 439: ... Status OK Table 18 71 HPSCSI_DeviceIndication Controller status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at time of indication PerceivedSeverity 2 Info IndicationTime Time of indication CIM_AlertIndication Description This SCSI HBA status has changed from non OK to OK AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class in...

Страница 440: ...the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other syste...

Страница 441: ...n CIM_AlertIndication Description A SCSI HBA status has changed to Error AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 3 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Replace this SCSI HBA SystemName Name of the computer syste...

Страница 442: ...Model Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName ...

Страница 443: ... non redundant AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Check status of all enclosure power supplies Ensure that power supplies have not failed Add or replace powe...

Страница 444: ...roduct ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation Loca...

Страница 445: ...upply has changed to Fully Redundant AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 302 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions No action is recommended SystemName Name of the computer system generating the indica...

Страница 446: ...name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name EnclosureName HP_BladeEncl...

Страница 447: ...ply status has changed to Degraded Redundancy AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 303 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Check status of all enclosure power supplies Ensure that power supplies have...

Страница 448: ...t ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationI...

Страница 449: ...on Description A Storage Enclosure Temperature sensor status changed from non OK to OK AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 307 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions No action is recommended SystemName...

Страница 450: ... SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInformation 0 BladeName HP_ComputerSystem Name Enclosu...

Страница 451: ... Warning Condition This indicates the enclosure temperature is above normal otherwise enclosure is still operating normally AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 308 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedAction...

Страница 452: ...f the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the propert...

Страница 453: ...e sensor status has changed to Critical An enclosure temperature is reaching the maximum allowed temperature for normal operation A shutdown is imminent Action is required before loss of data occurs AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 309 EventTime Time of the event or time of ...

Страница 454: ...SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When Impacte...

Страница 455: ...ation PerceivedSeverity 2 Info IndicationTime Time of indication CIM_AlertIndication Description The storage enclosure fan subsystem is operating properly AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 304 EventTime Time of the event or time of the indication if event time unknown Provide...

Страница 456: ... of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInfor...

Страница 457: ...tion A fan has failed but there are enough fans in the fan subsystem to keep the enclosure cool AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 305 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Ensure that the system is ...

Страница 458: ...uct ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation Locatio...

Страница 459: ...ans in the fan subsystem to keep the enclosure cool AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 306 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SCSI RecommendedActions Ensure that the system is adequately ventilated Check for proper room ...

Страница 460: ...D of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems When ImpactedDomain is 3 Enclosure the properties indicated with are populated BladeBay HP_BladeCSLocation LocationInfo...

Страница 461: ...CSI HBA 461 Table 18 81 HPSCSI_DeviceIndication Fan status change ERROR Property name Property implementation HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string ...

Страница 462: ...rofile 19 3Class implementations The following classes are implemented for Integrity server platforms The following classes describe software 19 3 1CIM_SoftwareIdentity CIM_SoftwareIdentity is used to represent software identity in a managed system The Windows implementation class is HP_SoftwareIdentity Table 19 2 Class CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement ...

Страница 463: ...active 0x8002 UninstalledActive The software identity is uninstalled and active 0x8003 UninstalledInActive The software identity is not installed and inactive Unknown if OperationalStatus 0 is 0 Unknown StatusDescriptions Software is installed and active if OperationalStatus 0 is 0x8000 InstalledActive Software is installed but not active if OperationalStatus 0 is 0x8001 InstalledInActive Software...

Страница 464: ...ntity version See VersionString property IdentityInfoType Array can contain the following An array property with the value CIM SoftwareFamily indicates a corresponding IdentityInfoValue property that is an invariant identifier that is the same across versions of software identity An array property with the value HPQ SoftwarePath indicates a corresponding IndentityInfoValue property that describes ...

Страница 465: ...System software 465 19 4Supported indications There are no indications produced for the software inventory profile implementation ...

Страница 466: ...s 20 3 1HP_RegisteredProfile and HP_RegisteredSubProfile Instances of HP_RegisteredProfile and HP_RegisteredSubProfile are populated for the implemented DMTF and SNIA SMI S storage profiles The following lists the properties implemented Table 20 2 Class HP_RegisteredProfile and HP_RegisteredSubProfile Property name Property implementation CIM_ManagedElement Caption See Tables 20 3 and 20 4 Descrip...

Страница 467: ...n DMTF Fan Profile PCI Device 1 0 0 CIM PCI Device DMTF PCI Device Profile Physical Asset 1 0 1 CIM Physical Asset DMTF Physical Asset Profile Power State Management 1 0 1 CIM Power State Management DMTF Power State Management Power Supply 1 0 1 CIM Power Supply DMTF Power Supply Profile Record Log 1 0 1 CIM Record Log DMTF Record Log Profile Sensors 1 0 1 CIM Sensors DMTF Sensors Profile Software...

Страница 468: ...A PhysicalPackage 12 0 SNIA Physical Package Profile SCSI HBA 1 2 0 SNIA HHRC 120 SNIA SCSI HBA Profile Software 1 2 0 SNIA Software 120 SNIA Software Profile Table 20 5 Property Values of HP_RegisteredSubProfile for SNIA Profiles RegisteredName Registered Version InstanceID Caption Description ElementName SAS Target Ports 1 2 0 SNIA SAS Target Ports 120 SNIA SAS Target Ports Subprofile SPI target...

Страница 469: ...HP Power Supply 1 3 0 HP Power Supply HP Power Supply Profile HP Power Supply Physical Asset 1 0 2 HP Power Supply Physical Asset HP Power Supply Physical Asset Profile HP Record Log 1 1 0 HP Record Log HP Record Log Profile HP SAS HBA 1 0 0 HP SASHBA 100 HP SAS HBA Profile HP SCSI HBA 1 0 0 HP SCSIHBA 100 HP SCSI HBA Profile HP Sensors 1 1 0 HP Sensors HP Sensors Profile HP Smart Array 1 3 0 HP S...

Страница 470: ...ependent ref CIM_RegisteredProfile referenced 20 3 4HP_ElementConformsToProfile HP_ElementConformsToProfile extends the class CIM_ElementConformsToProfile and associates an HP registered profile with the HP specific central class that defined the implementation of the profile The following properties are implemented Table 20 8 Class HP_ ElementConformsToProfile Property name Property implementatio...

Страница 471: ... Host Discovered Resources Profile SPI Target Ports Profile SAS Target Ports Profile HP Profile Registration Profile HPWMITape dll Provider Installation Files Cpqmdisk dll Cpqmscsi dll Cpqmsas dll HPTape mof HPWMITape mof HPWMITapeEventMetaData mof HPWMITapeEventRegistration mof HPWMITapeInterop mof HPWMITapeRegistration mof 21 2Use Cases For use cases see the HP Standalone Tape Drive Profile P001...

Страница 472: ...lassName HP_WinComputerSystem SystemName The network name of the host system CIM_MediaAccessDevice MountCount Number of times a tape has been loaded NeedsCleaning True if the tape drive needs cleaning CIM_TapeDrive EOTWarningZoneSize Not implemented MaxRewindTime Not implemented HP_TapeDrive ReplaceCleaningTape True if the cleaning tape present in the drive has exceeded its cleaning count and need...

Страница 473: ...to be reread from the device since the tape device driver was last loaded ErrorCount The total number of read write errors since the tape device driver was last loaded UncorrCount The total number of read write errors that could not be corrected since the tape device driver was last loaded BytesCount The total number of bytes read written to the tape currently installed in the device HPWMITape_Tap...

Страница 474: ..._ManagedSystemElement CIM_PhysicalElement CreationClassName HPWMITape_PhysicalTape Tag Uniquely identifies an instance of HPWMITape_TapeDriveMediaLocation CIM_PhysicalComponent RemovalConditions 0 Unknown CIM_PhysicalMedia Capacity Not implemented True if tape is a cleaning cartridge CleanerMedia False if unknown DualSided False LabelFormats 0 0 Barcode 0 Readable LabelStates 0 1 Unreadable MaxMou...

Страница 475: ...stanceID Uniquely identifies an instance of HPWMITape_TapeDriveCapabilities CIM_EnabledLogicalElementCapabilities RequestedStatesSupported An array of supported states that can be requested This should always be an array with element values set to zero indicating an empty array HPWMITape_TapeDriveCapabilities 21 3 6HPWMITape_TapeDriveEnclosure Table 21 7 Class HPWMITape_TapeDriveEnclosure Property...

Страница 476: ...emovalConditions 2 Not Applicable 3 Removable when off 4 Removable when on or off CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure 0 Unknown Location 1 Internal 2 External HPWMITape_TapeDriveEnclosure 21 3 7HPWMITape_Product Table 21 8 Class HPWMITape_Product Property name Property implementation CIM_ManagedElement ElementName Long name for the device CIM_Product IdentifyingNumber Device serial n...

Страница 477: ..._ServiceAccessPoint CreationClassName HPWMITape_SCSIProtocolEndpoin Name Serial Number of the Tape Drive SystemCreationClassName HP_WinComputerSystem SystemName Network name of the host system CIM_ProtocolEndpoint ProtocolIFType 0 Unknown CIM_SCSIProtocolEndpoint 3 Parallel SCSI ConnectionType 8 SAS Role 3 Target HPSA_SCSIProtocolEndpoint 21 3 9HPWMITape_TapeDriveFirmware Table 21 10 Class HPWMITa...

Страница 478: ...hey first ship and this value is incremented if future versions are shipped which are not firmware compatible with the predecessor If the tape drive does not support this capability a value of 0 is returned HPWMITape_TapeDriveFirmware 21 3 10HPWMITape_TapeDriveSPIPort Table 21 11 Class HPWMITape_TapeDriveSPIPort Property name Property implementation CIM_ManagedElement CIM_ManagedSystemElement 0 Un...

Страница 479: ...rs The number of parity errors on this SCSI bus PhaseErrors The number of time the SCSI bus entered invalid state SelectTimeouts The number of times the device timed out HPWMITape_TapeDriveSPIPort 21 3 11HPWMITape_TapeDriveSASPort Table 21 12 Class HPWMITape_TapeDriveSASPort Property name Property implementation CIM_ManagedElement CIM_ManagedSystemElement 0 Unknown OperationalStatus 0 1 Other 2 OK...

Страница 480: ...workPort CIM_SASPort HPWMITape_TapeDriveSASPort 21 3 12HPWMITape_TapeSystemDevice Association Table 21 13 Association HPWMITape_TapeSystemDevice Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HPWMITape_TapeDrive 21 3 13HPWMITape_LogicalPortSystemDevice Association Table 21 14 Association HPWMITape_LogicalPortSystemDevice Property name Property implementatio...

Страница 481: ...a 21 3 16HPWMITape_RealizeStorageMediaLocation Association Table 21 17 Association HPWMITape_RealizeStorageMediaLocation Property name Property implementation Antecedent HPWMITape_TapeDriveMediaLocation Dependent HPWMITape_TapeDrive 21 3 17HPWMITape_TapeInTapeDriveMediaLocation Association Table 21 18 Class HPWMITape_TapeInTapeDriveMediaLocation Property name Property implementation Antecedent HPW...

Страница 482: ...e 21 3 20HPWMITape_TapeDriveToTapeDriveFirmware Association Table 21 21 Association HPWMITape_TapeDriveToTapeDriveFirmware Property name Property implementation Antecedent HPWMITape_TapeDriveFirmware Dependent HPWMITape_TapeDrive 21 3 21HPWMITape_InstalledDriveFirmware Association Table 21 22 Association HPWMITape_TapeDriveToTapeDriveFirmware Property name Property implementation InstalledSoftware...

Страница 483: ...mputerSystem Dependent HPWMITape_SCSIProtocolEndpoint 21 3 24HPWMITape_SCSIInitiatorTargetLUPath Association Table 21 25 Association HPWMITape_SCSIInitiatorTargetLUPath Property name Property implementation Initiator CIM_SCSIProtocolEndpoint LogicalUnit HPWMITape_TapeDrive 21 3 25HPWMITape_SCSIProtocolEndpointLogicalPort Association Table 21 26 Association HPWMITape_SCSIProtocolEndpointLogicalPort...

Страница 484: ...f SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary See HPWMITapeEventMetaData mof EventCategory 7 Secondary Storage Device ProbableCause 1 Other ProbableCauseDescription Tape drive status changed to Unknown ProviderVersion Provider version generating the indication ...

Страница 485: ...mware VersionString HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number It must match the HP_StorageEnclosure SerialNumber HP_DeviceIndication DeviceModel Enclosure Model string HP_TapeDriveDeviceIndication 21 4 2Drive status changed to OK Table 21 28 HP_TapeDriveDeviceIndication Drive status changed to OK Property name Property implementation CIM_Indication Indicat...

Страница 486: ...the computer system generating the indication 69 Windows 2003 32 bit OSType 70 Windows 2003 64 bit 76 Windows 2008 32 bit 77 Windows 2008 64 bit 103 Windows 2008 R2 OSVersion Operating system version of the computer system generating the indication in the form major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number ...

Страница 487: ...M_AlertIndication Description See HPWMITapeEventMetaData mof AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 503 Tape drive status changed to Degraded EventTime Time of the event or time of the indication if the event time is unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData mof Syste...

Страница 488: ...ation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems HP_Har...

Страница 489: ...f the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary See HPWMITapeEventMetaData mof EventCategory 7 Secondary Storage Device ProbableCause 35 Performance Degraded ProbableCauseDescription Tape drive is not in operating mode or non responsive ProviderVersion Provider version generating t...

Страница 490: ...iveFirmware VersionString HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number It must match the HP_StorageEnclosure SerialNumber HP_DeviceIndication DeviceModel Enclosure Model string HP_TapeDriveDeviceIndication 21 4 5New Tape Drive Found Table 21 31 HP_TapeDriveDeviceIndication Drive status changed to Failed Property name Property implementation CIM_Indication Ind...

Страница 491: ...the computer system generating the indication 69 Windows 2003 32 bit OSType 70 Windows 2003 64 bit 76 Windows 2008 32 bit 77 Windows 2008 64 bit 103 Windows 2008 R2 OSVersion Operating system version of the computer system generating the indication in the form major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number ...

Страница 492: ...ertIndication Description See HPWMITapeEventMetaData mof AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 506 Tape drive status changed to Offline EventTime Time of the event or time of the indication if the event time is unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData mof SystemName...

Страница 493: ...ndication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems HP_HardwareIndication HWFirmwareVersion Enclosure F W version string It must match t...

Страница 494: ... CreationClassName of the computer system generating the indication HP_AlertIndication Summary See HPWMITapeEventMetaData mof EventCategory 7 Secondary Storage Device ProbableCause 73 Element Missing ProbableCauseDescription Missing tape drive that was OK ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of all the IP...

Страница 495: ...facturer string HWSerialNumber Enclosure Serial Number It must match the HP_StorageEnclosure SerialNumber HP_DeviceIndication DeviceModel Enclosure Model string HP_TapeDriveDeviceIndication 21 4 8Failed Drive Now Missing Table 21 34 HP_TapeDriveDeviceIndication Failed Drive Now Missing Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication Per...

Страница 496: ...ndows 2003 32 bit OSType 70 Windows 2003 64 bit 76 Windows 2008 32 bit 77 Windows 2008 64 bit 103 Windows 2008 R2 OSVersion Operating system version of the computer system generating the indication in the form major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication Sy...

Страница 497: ...ance AlertingElementFormat 2 CIMObjectPath AlertType 5 Device Alert EventID 509 Offline drive now missing EventTime Time of the event or time of the indication if the event time is unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData mof SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating...

Страница 498: ...el name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems HP_HardwareIndication HWFirmwareVersion Enclosure F W version string It must match the HP_TapeDriveFirmware VersionString HWManufacturer Enclosure Manufacturer string HWSerialNumber Enc...

Страница 499: ...eEventMetaData mof EventCategory 7 Secondary Storage Device ProbableCause 73 Element Missing ProbableCauseDescription Missing tape drive that was Degraded ProviderVersion Provider version generating the indication in the form major minor revision build NetworkAddresses Contains a list of all the IP addresses IPv4 and IPv6 of the computer system generating the indication 69 Windows 2003 32 bit OSTy...

Страница 500: ...del Enclosure Model string HP_TapeDriveDeviceIndication 21 4 11Tape Drive Cleaning Required Table 21 37 HP_TapeDriveDeviceIndication Tape Drive Cleaning Required Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 Major IndicationTime Time of indication CIM_AlertIndication Description See HPWMITapeEventMetaData mof Alert...

Страница 501: ...it 103 Windows 2008 R2 OSVersion Operating system version of the computer system generating the indication in the form major minor build SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model...

Страница 502: ...ormat 2 CIMObjectPath AlertType 5 Device Alert EventID 512 Cleaning tape replacement required EventTime Time of the event or time of the indication if the event time is unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData mof SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indicat...

Страница 503: ...ber of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 Enclosure for c Class blade systems ImpactedDomain 4 System for all other systems HP_HardwareIndication HWFirmwareVersion E...

Страница 504: ...y version of the profiles referenced No configuration functionality is supported by this provider 22 3Class implementations The following sections define the supported classes and properties for the Host Discovered Resources provider 22 3 1HPHDR_ComputerSystem HPHDR_ComputerSystem represents the top level system There is one instance on a host Table 22 2 Class HPHDR_ComputerSytem Property name Pro...

Страница 505: ...th Name of the Initiator For example Scsi0 ElementName Name of the OS volume associated to this Initiator Path combination For example Volume a0acd7e0 442d 11dc 8bd2 806d6172696f CIM_EnabledLogicalElement EnabledDefault 2 Enabled RequestedState 12 Not Applicable CIM_ManagedSystemElement Name The SCSI ID in the form SCSI Initiator portid pathid For example SCSIInitiator 1 2 where 1 is the initiator...

Страница 506: ...ment Name The SCSI ID in the form SCSI Initiator portid pathid Targetid For example SCSITarget 1 2 3 where 1 is the initiator ID 2 is the path ID and 3 is the target ID CIM_ServiceAccessPoint CreationClassName HPHDR_SCSIProtocolEndpointTarget SystemCreationClassName HPHDR_ComputerSystem SystemName Name of the host For example aa bb abccorp net CIM_SCSIProtocolEndpoint ConnectionType 1 Other Roll 3...

Страница 507: ...sociated to this logical disk For example Volume a0acd7e0 442d 11dc 8bd2 806d6172696f ElementName The SCSI ID of the Logical Disk with full path in the form SCSILUN Initiatorid pathid targetid LUN For example SCSILUN 1 2 3 4 where 1 is the initiator ID 2 is the path ID 3 is the target ID and 4 is the LUN CIM_EnabledLogicalElement EnabledDefault 2 Enabled EnabledState 5 Not Applicable RequestedStat...

Страница 508: ...HPHDR_LogicalDisk Property name Property implementation CIM_ManagedElement Caption Description for the Target Based Mangement Point For example Primary Remote Access Point for Volume 394cd96b 8678 11dd a09c 001e0bcb7a62 ElementName Name of the Drive Letter associated to this Remote AccessPoint For example E Description Description of the Remote Service Access Point For example Accesspoint for the ...

Страница 509: ...essPoint Association Table 22 7 Class HPHDR_LogicalDiskRemoteServiceAccessPoint Property name Property implementation Antecedent HPHDR_LogicalDisk Dependent HPHDR_RemoteServiceAccessPoint 22 3 7HPHDR_ComputerSystemRemoteServiceAccessPoint Association Table 22 8 Class HPHDR_ComputerSystemRemoteServiceAccessPoint Property name Property implementation Antecedent HPHDR_ComputerSystem Dependent HPHDR_R...

Страница 510: ...iator Property name Property implementation Antecedent HPHDR_ComputerSystem Dependent HPHDR_SCSIProtocolEndPointInitiator 22 3 10HPHDR_ComputerSystemSCSIProtocolEndpointTarget Association Table 22 11 Class HPHDR_ComputerSystemSCSIProtocolEndpointTarget Property name Property implementation Antecedent HPHDR_ComputerSystem Dependent HPHDR_SCSIProtocolEndPointTarget ...

Страница 511: ...For more information 511 23For more information http www dmtf org http www snia org http www hp com ...