CAUTION:
The enclosure fans might still be running when the server blade is in standby mode. Opening the
lever removes all power from the server blade.
Procedure
1.
Power off the server blade. (
on page 25)
2.
If the blade is conjoined, then remove the Blade Link (
Removing the Blade Link for BL870c i4 or
on page 113).
3.
Remove the server blade.
4.
Place the server blade on a flat, level, and antistatic surface.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:
Populate server blade enclosure bays with a server blade or server blade blank. Operating the
enclosure without a server blade or server blade blank causes improper airflow and cooling
which can lead to thermal damage.
To replace the component, reverse the removal procedure.
Access panel
The access panel is located on the right side of the server blade (when mounted in an enclosure).
Procedure
1.
Power off the server blade and remove it from the server blade enclosure. (
on page 112).
2.
Lift the access panel latch.
Access panel