Or, from the HP SIM user interface, select the managed systems, then from the
Diagnose
menu, select
Troubleshoot Insight Dynamics
, then select
Check Managed Node
Configuration
.
4.
If you are unable to resolve issues with one of your managed systems, you can install or
copy
vseassist
to the managed system and run it from the command line there. In the
following command, replace cms with the fully qualified domain name of the CMS:
vseassist -s -h
cms
Options
If no options are specified, the command syntax is displayed and the command exits with return
code 3.
The
vseassist
command recognizes the following options. For each option, a mnemonic is
shown in parentheses to help you remember the option letter.
-a
(All) Perform all checks:
1.
Check the configuration of the CMS (as with the
-c
option).
2.
Check the communication between the CMS and the specified
managed systems (as with the
-l
option). If no managed systems
are specified, then perform this check on all systems in the
All
VSE Resources
collection.
3.
Check the configuration of the specified managed systems (as
with the
-r
option). If no managed systems are specified, then
perform this check on all compatible systems in the
All VSE
Resources
collection.
-c
(CMS) Check the configuration of the CMS.
Note: For a Windows CMS, if IOAssist is installed, additional IOAssist
resource and CMS configuration checks will be launched.
-l
(Link) From the CMS, check the communication between the CMS
and the managed systems specified by the
-n
and
-g
options. Some
of the problems detected with this option include expired licenses,
no open WBEM ports, and improperly configured SSH authentication.
These checks will verify that the CMS can communicate with the
managed systems in order to perform management functions.
This option requires one or more
-n
or
-g
options.
Note: On Windows and HP-UX CMS,
vseassist
will obtain the
port on which to attempt managed node communication from the
file
globalsettings.props
(see FILES section below). If no port
configuration is present, port 22 will be used.
-r
(Remote) From the CMS, check the configuration of the HP-UX or
Windows managed systems specified by the
-n
and
-g
options
(
vseassist
does not provide configuration checks for Linux
managed systems). This option uses mxexec to copy the
vseassist
command to the managed systems, where it is executed with the
-s
option.
In order for the
-r
option to succeed, the CMS must be able to
communicate with the managed systems (as checked by the
-l
option).
This option requires one or more
-n
or
-g
options.
-n
nodename
(Node) Specifies the name of a VSE managed system using the node
name by which the system is known to the CMS (as reported by
37
Содержание Insight Dynamics 6.2
Страница 24: ...24 ...
Страница 35: ...Command reference 35 ...
Страница 46: ...46 ...
Страница 53: ...53 ...
Страница 54: ......