HSG80 Array Controller V8.7 Maintenance and Service Guide
5–43
Upgrading the Subsystem
Figure 5–6: DIMM components
8. If replacing DIMMs (see Figure 5–6):
a.
Press down on the DIMM retaining clip
3
at both ends of the DIMM
1
being
removed.
b.
Gently remove the DIMM from the DIMM slot
2
.
c.
Insert the new DIMM
1
straight into the slot, ensuring that the notches in the
DIMM align with the tabs in the slot.
d. Repeat step a through step c for each DIMM.
9. In a dual-redundant controller configuration, repeat step 5 through step 8, as
appropriate, for the other cache module.
IMPORTANT: In a dual-redundant controller configuration, both cache modules must contain
the same memory configuration. DO NOT proceed unless both cache modules contain identical
amounts of cache memory.