5–32
HSG80 Array Controller V8.7 Maintenance and Service Guide
Upgrading the Subsystem
6. Enter the software version of the patch to delete and press Enter/Return. The
following display appears:
Patch Number to delete?
7. Enter the patch number to delete and press Enter/Return. The following display
appears:
The following patches have been selected for deletion:
Software Version - Patch #
xxxx xxxx
Do you wish to continue (y/n) [n] ?
8. Enter Y(es) and the patches are deleted. The following menu appears:
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
9. Enter option 0.
10. Press the controller reset button to restart the controller.
11. For dual-redundant controller configurations, repeat step 1 through step 10 for the
second controller.
Listing Software Patches
Use the following steps to list software patches.
1. Connect a PC or terminal to the controller maintenance port.
2. Start CLCP with the following command:
RUN CLCP