background image

 

51 

Table 11 Power supply specifications 

Power supply 

Specifications 

Remarks 

650W AC 

 

Rated input voltage:  
100 VAC to 240 VAC @ 50 Hz or 60 Hz

 

Max input voltage:  
90 VAC to 264 VAC @ 47 Hz to 63 Hz 

 

Max output power:  
650 W 

For more information about the 
power supplies, see 

HPE A58x0AF 

650W AC (JC680A) & 650W DC 
(JC681A) Power Supplies User 
Guide 

or

 HPE FlexFabric Switch 

650W 48V Hot Plug NEBS 
Compliant DC Power Supply 
(JH336A) User Guide.

 

650W DC 

 

Rated input voltage:  
–40 VDC to –60 VDC 

 

Max input voltage:  
–40 VDC to –72 VDC 

 

Max output power:  
650 W 

 

Fan trays 

Table 12 Fan tray specifications 

Item Specifications 

LSWM1HFANSC (for the HPE 5930-32 QSFP+/HPE 5930-32 QSFP+ TAA/HPE 
5930-2Slot+2QSFP+/HPE 5930-2Slot+2QSFP+ TAA switches) 

Fans 

Two 40 × 40 × 56 mm (1.57 × 1.57 × 2.2 in) fans

 

Fan speed 

21000 R.P.M

 

Max airflow 

70 CFM

 

Airflow direction 

Back to front (Fans draw air from the power supply side to the network port side.)

 

Input voltage 

12 V

 

Maximum power 
consumption 

60 W

 

Documentation 
reference 

HPE LSWM1HFANSC and LSWM1HFANSCB Fan Assemblies Installation 

LSWM1HFANSCB (for the HPE 5930-32 QSFP+/HPE 5930-32 QSFP+ TAA/HPE 
5930-2Slot+2QSFP+/HPE 5930-2Slot+2QSFP+ TAA switches) 

Fans 

Two 40 × 40 × 56 mm (1.57 × 1.57 × 2.2 in) fans

 

Fan speed 

21000 R.P.M

 

Max airflow 

70 CFM

 

Airflow direction 

Front to back (Fans draw air from the network port side to the power supply side.)

 

Input voltage 

12 V

 

Maximum power 
consumption 

60 W

 

Documentation 
reference 

HPE LSWM1HFANSC and LSWM1HFANSCB Fan Assemblies Installation 

Содержание HPE FlexFabric 5930

Страница 1: ...HPE FlexFabric 5930 Switch Series Installation Guide Part number 5998 7149s Document version 6W103 20160516 ...

Страница 2: ...nd 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise ...

Страница 3: ...nnecting the power cord 26 Connecting the 650W AC power supply 27 Connecting the 650W DC power supply 27 Installing Removing an interface module 28 Verifying the installation 30 Accessing the switch for the first time 31 Setting up the configuration environment 31 Connecting the console cable 31 Serial console cable 31 USB mini console cable 32 Connection procedure 32 Setting terminal parameters 3...

Страница 4: ...t 54 SFP port 55 QSFP port 57 1 10GBase T autosensing Ethernet port 59 LEDs 59 System status LED 59 SFP port LED 60 QSFP port LED 60 Management Ethernet port LEDs 60 1 10GBase T autosensing Ethernet port LEDs 61 Fan tray alarm LEDs 61 Appendix D Cooling system 62 HPE 5930 32 QSFP HPE 5930 32 QSFP TAA HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA cooling system 62 HPE 5930 4Slot HPE 5930 4Slot TAA ...

Страница 5: ...CB JG553A HPE X712 Back Power Side to Front Port Side Airflow High Volume Fan Tray LSWM1HFANSC JH185A HPE 5930 4 slot Back Power Side to Front Port Side Airflow Fan Tray LSWE1BFANSC JH186A HPE 5930 4 slot Front Port Side to Back Power Side Airflow Fan Tray LSWE1BFANSCB For regulatory identification purposes the HPE 5930 32 QSFP Switch and HPE 5930 32 QSFP TAA Switch are assigned Regulatory Model N...

Страница 6: ...w green protection grounding cable before power on Make sure the operating voltage is in the required range To avoid electrical shocks do not open the chassis while the switch is operating or when the switch is just powered off When replacing FRUs including power supplies fan trays and interface modules wear an ESD wrist strap to avoid damaging the units Examining the installation site The switch ...

Страница 7: ...ow In the worst case electrostatic adsorption can cause communication failure Table 2 Dust concentration limit in the equipment room Substance Concentration limit particles m Dust 3 x 10 4 no visible dust on the tabletop over three days NOTE Dust diameter 5 μm The equipment room must also meet limits on salts acids and sulfides to eliminate corrosion and premature aging of components as shown in T...

Страница 8: ...laser device Installation tools No installation tools are provided with the switch Prepare the following tools yourself Phillips screwdriver ESD wrist strap Marker Installation accessories Table 4 Installation accessories Product code Description Quantity Applicable models 5066 0850 1 U mounting bracket kit including one pair of mounting brackets and eight M4 countersunk screws 1 kit HPE 5930 32 Q...

Страница 9: ...PE 5930 32 QSFP TAA HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA 5185 8684 2 U short slide rail kit including one pair of slide rails and four M4 countersunk screws 1 kit HPE 5930 4Slot HPE 5930 4Slot TAA 5184 6723 Grounding cable 1 All HPE 5930 switches 5185 9579 Grounding screw 2 All HPE 5930 switches 5003 2403 Interface module filler module 1 HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA HPE 5...

Страница 10: ...tration only The cable delivered for your country or region might use a different color scheme 1 650W DC power supply 5185 8748 Removable cable tie 1 All power supplies 5185 8627 Console cable 1 All HPE 5930 switches 5187 9022 QSFP dust plug Optional HPE 5930 32 QSFP HPE 5930 32 QSFP TAA HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA ...

Страница 11: ...erprise shall not be liable for any consequence caused thereby Figure 1 Hardware installation flow Ground the switch Install the switch Start Connect the power cords Verify the installation Power on the switch Operating correctly Power off the switch Resolve the problem No Yes Install fan trays Install power supplies Install interface cards No Yes Install interface cards Operating correctly Resolv...

Страница 12: ...ne pair See Figure 2 N A 1U high including one pair of chassis rails and one pair of slide rails See Figure 5 HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA compliant 1U high one pair See Figure 3 N A 1U high including one pair of chassis rails and one pair of slide rails See Figure 5 HPE 5930 4Slot HPE 5930 4Slot TAA 2U high one pair See Figure 4 One pair provided See Figure 4 2U high including on...

Страница 13: ...PE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switch Figure 4 Mounting brackets for the HPE 5930 4Slot HPE 5930 4Slot TAA switch 1 Cable management bracket 2 Mounting bracket Figure 5 1U rack mounting rail kit 1 Chassis rail 2 Slide rail 1 2 ...

Страница 14: ...the requirements described in Table 6 To secure the switch to the rack you must install not only mounting brackets but also chassis rails and slide rails Table 6 Distance requirements between the front and rear rack posts Switch model Installation method Minimum distance Maximum distance HPE 5930 32 QSFP HPE 5930 32 QSFP TAA Using provided mounting brackets and chassis rails 405 mm 15 94 in 854 mm...

Страница 15: ... 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switch provides two grounding points primary grounding point with a grounding sign and auxiliary grounding point 1 Figure 8 Mounting and grounding positions on the HPE 5930 32 QSFP HPE 5930 32 QSFP TAA switch 1 Auxiliary grounding point 2 2 Power supply side mounting position 3 Primary grounding point 4 Auxiliary grounding point 1 5 Network port side mounting ...

Страница 16: ...t side mounting position align the chassis rails with the screw holes at the rear of the side panels see Figure 13 Figure 14 and Figure 15 3 Use M4 screws provided to attach the chassis rails to the chassis NOTE Secure the mounting brackets and chassis rails to both sides of the chassis in the same way To install the mounting brackets at the network port side mounting position on the HPE 5930 2Slo...

Страница 17: ...the mounting brackets Figure 12 Attaching the mounting brackets and chassis rails to the HPE 5930 4Slot HPE 5930 4Slot TAA switch power supply side mounting position for the mounting brackets Figure 13 Attaching the mounting brackets and chassis rails to the HPE 5930 32 QSFP HPE 5930 32 QSFP TAA switch network port side mounting position for the mounting brackets ...

Страница 18: ...ints you must connect the grounding cable to the grounding point before you mount the switch in the rack As a best practice connect the grounding cable to the primary grounding point or auxiliary grounding point 1 The grounding cable and grounding screw that come with the switch are suitable only for these two grounding points To use auxiliary grounding point 2 prepare a grounding cable yourself T...

Страница 19: ...rack This section uses the 1U slide rails as an example To attach the slide rails to the rack 1 Identify the rack attachment position for the slide rails 2 Install cage nuts user supplied in the mounting holes in the rack posts 3 Align the screw holes in one slide rail with the cage nuts in the rack post on one side and use screws user supplied to attach the slide rail to the rack as shown in Figu...

Страница 20: ...ligns the chassis rails with the slide rails on the rack posts b Pushes the switch slowly to slide the chassis rails along the slide rails until the mounting brackets are flush with the rack posts 6 Another person uses screws user supplied to attach the mounting brackets to the rack To secure the switch in the rack make sure the front ends of the slide rails reach out of the chassis rails The rack...

Страница 21: ...FP HPE 5930 2Slot 2QSFP TAA switch in the rack network port side mounting position for the mounting brackets Figure 20 Mounting the HPE 5930 4Slot HPE 5930 4Slot TAA switch in the rack power supply side mounting position for the mounting brackets ...

Страница 22: ...1 are for illustration only Grounding the switch WARNING Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection The power input end of the switch has a noise filter whose central ground is directly connected to the chassis to form the chassis ground commonly known as PGND You must securely connect this chassis ground to the earth so the faradism and l...

Страница 23: ...ng post on the grounding strip and secure the ring terminal to the grounding post with the hex nut Figure 22 Connecting the grounding cable to a grounding strip 1 Hex nut 2 Ring terminal 3 Grounding post 4 Grounding strip As a best practice connect the grounding cable to the primary grounding point or auxiliary grounding point 1 on the switch The grounding cable and grounding screw provided with t...

Страница 24: ...Installing removing a fan tray Follow these guidelines when you install or remove a fan tray Do not power on the switch when the switch has no fan trays installed You must install two fan trays of the same model for the switch When a fan tray fails during the switch operation and the ambient temperature is not higher than 27 C 80 6 F replace the fan tray within 24 hours and keep the failed fan tra...

Страница 25: ...e fan tray along the guide rails into the slot until the fan tray seats in the slot and has a firm contact with the backplane see callout 1 in Figure 24 4 Fasten the captive screw on the fan tray with a Philips screwdriver until the fan tray is securely attached in the chassis see callout 2 in Figure 24 If the captive screw cannot be tightly fastened verify the installation of the fan tray Figure ...

Страница 26: ...ewdriver until it is fully disengaged from the switch chassis 3 Grasp the handle of the fan tray with one hand and pull the fan tray part way out of the slot Support the fan tray bottom with the other hand and pull the fan tray slowly along the guide rails out of the slot 4 Place the removed fan tray in an antistatic bag Removing an LSWM1BFANSC or LSWM1BFANSC fan tray 1 Wear an ESD wrist strap and...

Страница 27: ...tallation and procedures in Figure 27 and Figure 28 to avoid any bodily injury or damage to the switch Provide a separate circuit breaker for each power supply The switch comes with the power supply slots empty and filler panels for the power supply slots as accessories For more information about the power supplies available for the switches see Power supplies Figure 27 Installation procedure Figu...

Страница 28: ...are the same for the HPE FlexFabric 5930 switches This section uses the HPE 5930 32 QSFP HPE 5930 32 QSFP TAA switch as an example To install a power supply 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Unpack the power supply and verify that the power supply model is correct 3 Correctly orient the power supply with the power supply slot see Figure 2...

Страница 29: ...d for your country or region might use a different color scheme When you connect the power cord always identify the polarity symbol on its wires The power supply removing procedures are the same for the HPE FlexFabric 5930 switches This section uses the HPE 5930 32 QSFP HPE 5930 32 QSFP TAA switch as an example To remove a power supply 1 Wear an ESD wrist strap and make sure it makes good skin con...

Страница 30: ...finger 2 Pull the power cord connector out Figure 32 Removing the power supply 1 Pivot the latch to the right with your thumb 2 Pull the power supply out Connecting the power cord WARNING Provide a circuit breaker for each power input When you connect a power cord make sure the circuit breaker is switched off ...

Страница 31: ...ed for your country or region might use a different color scheme When you connect the power cord always identify the polarity symbol on its wires To connect the 650W DC power supply 1 Unpack the DC power cord identify the plug for connecting to the power supply orient the plug with the power receptacle on the power supply and insert the plug into the receptacle see Figure 34 The receptacle is fool...

Страница 32: ...re the same This section uses the LSWM18QC interface module as an example Installing an interface module 1 Wear an ESD wrist strap and make sure the wrist strap makes good skin contact and is reliably grounded 2 Optional If the target interface module slot has a filler panel installed remove the filler panel Figure 35 uses the HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switch as an example To r...

Страница 33: ...e remove the cable from it to avoid cable damage After removing an interface module if no new interface module is to be installed install the filler panel as soon as possible to prevent dust and ensure good ventilation in the device To remove an interface module 1 Prepare an anti static bag 2 Wear an ESD wrist strap and make sure the wrist strap makes good skin contact and is reliably grounded 3 P...

Страница 34: ...heat dissipation around the switch and the rack is stable The grounding cable is securely connected The correct power source is used The power cords are correctly connected All the interface cables are cabled indoors If any cable is routed outdoors verify that the socket strip with lightning protection and lightning arresters for network ports have been correctly connected ...

Страница 35: ... use the two ways together on the same switch The example uses a console cable to connect a console terminal PC to the serial console port on the switch Figure 39 Connecting the serial console port to a terminal Connecting the console cable Serial console cable A serial console cable is an 8 core cable with a crimped RJ 45 connector at one end for connecting to the serial console port of the switc...

Страница 36: ... port The serial ports on PCs do not support hot swapping If the switch has been powered on connect the serial console cable to the PC before connecting to the switch and when you disconnect the cable first disconnect from the switch To connect to the configuration terminal through the USB mini console cable 1 Connect the standard USB Type A connector to the USB port of the configuration terminal ...

Страница 37: ...33 Figure 41 Device Driver Installation Wizard 5 Click Continue Anyway if the following dialog box appears Figure 42 Software Installation 6 Click Finish ...

Страница 38: ...d terminal settings Bits per second 9600 Data bits 8 Stop bits 1 Parity None Flow control None Powering on the switch Before powering on the switch verify that the following conditions are met The power cord is correctly connected The input power voltage meets the requirement of the switch The console cable is correctly connected The configuration terminal a PC for example has started and its seri...

Страница 39: ...e matching release notes for the device After the startup completes you can access the CLI to configure the switch For more information about the configuration commands and CLI see HPE FlexFabric 5930 Switch Series Configuration Guide and HPE FlexFabric 5930 Switch Series Command References ...

Страница 40: ... between two switches use the 10 GE or 40 GE ports IRF fabric setup flowchart Figure 44 IRF fabric setup flowchart To set up an IRF fabric Step Description 1 Plan IRF fabric setup Plan the installation site and IRF fabric setup parameters Planning IRF fabric size and the installation site Identifying the master switch and planning IRF member IDs Planning IRF topology and connections Identifying ph...

Страница 41: ...ber switches Plan the installation site depending on your network solution as follows Place all IRF member switches in one rack for centralized high density access Distribute the IRF member switches in different racks to implement the top of rack ToR access solution for a data center As your business grows you can plug HPE FlexFabric 5930 switches into the IRF fabric to increase the switching capa...

Страница 42: ...t connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch The IRF port connections in the two figures are for illustration only and more connection methods are available Figure 45 IRF fabric in daisy chain topology Figure 46 IRF fabric in ring topology You can provide the following IRF physical connections between HPE FlexFabric 5930 switches ...

Страница 43: ...itches are all in one equipment room choose twisted pair cables or SFP QSFP cables For more information about available transceiver modules and cables see Appendix C Ports and LEDs The following subsections describe several IRF connection schemes recommended by Hewlett Packard Enterprise and all these schemes use a ring topology Connecting the IRF member switches in one rack Figure 47 shows an exa...

Страница 44: ... about configuring basic IRF settings see HPE FlexFabric 5930 Switch Series IRF Configuration Guide Connecting the physical IRF ports CAUTION Wear an ESD wrist strap when you connect cables or transceiver modules and optical fibers For more information see the installation guide for the transceiver modules Use cables or transceiver modules and optical fibers to connect the IRF member switches as p...

Страница 45: ...isplay irf configuration Display IRF fabric topology information display irf topology NOTE To avoid IP address collision and network problems configure at least one multi active detection MAD mechanism to detect the presence of multiple identical IRF fabrics and handle collisions For more information about MAD detection see HPE FlexFabric 5930 Switch Series IRF Configuration Guide ...

Страница 46: ...problems the Alarm LED on the fan tray is steady yellow and the system outputs alarm messages To replace a failed fan tray see Installing removing a fan tray Follow these guidelines when you install or remove a fan tray Do not power on the switch when the switch has no fan trays installed You must install two fan trays of the same model for the switch When a fan tray fails during the switch operat...

Страница 47: ... following settings are configured for the terminal Baud rate 9600 Data bits 8 Stop bits 1 Parity None Flow control None 4 If the problem persists contact Hewlett Packard Enterprise Support Garbled terminal display The configuration terminal displays garbled text To resolve the problem 1 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Stop bits 1 Parit...

Страница 48: ... The HPE 5930 32 QSFP HPE 5930 32 QSFP TAA switch comes with the two power supply slots empty and a filler panel as an accessory You can install one or two power supplies for the switch as needed In Figure 51 two 650W AC power supplies are installed in the power supply slots For more information about installing and removing power supplies see Installing removing a power supply The HPE 5930 32 QSF...

Страница 49: ...h comes with interface module slot 1 empty and interface module 2 installed with a filler panel You can install one or two interface modules for the switch as needed In Figure 53 two LSWM18QC interface modules are installed in the interface module slots For more information about installing and removing interface modules see Installing Removing an interface module The HPE 5930 2Slot 2QSFP HPE 5930...

Страница 50: ...NSC fan trays are installed in the fan tray slots For more information about installing and removing fan trays Installing removing a fan tray Figure 55 Left side panel 1 Primary grounding point 2 Auxiliary grounding point 1 HPE 5930 4Slot HPE 5930 4Slot TAA Figure 56 Front panel 1 Interface module slot 1 2 Interface module slot 2 3 Interface module slot 4 4 Interface module slot 3 2 1 3 4 ...

Страница 51: ...installing and removing interface modules see Installing Removing an interface module The HPE 5930 4Slot HPE 5930 4Slot TAA switch comes with the four power supply slot empty and three filler panels as accessories You can install two to four power supplies for the switch as needed In Figure 57 two 650W AC power supplies are installed in the power supply slots For more information about installing ...

Страница 52: ... 4 AC input voltage Rated voltage 100 VAC to 240 VAC 50 or 60 Hz Max voltage 90 VAC to 264 VAC 47 to 63 Hz DC input voltage Rated voltage 40 VDC to 60 VDC Max voltage 40 VDC to 72 VDC Minimum power consumption Single AC input 175 W Dual AC inputs 190 W Single DC input 172 W Dual DC inputs 183 W Single AC input 105 W Dual AC inputs 116 W Single DC input 98 W Dual DC inputs 115 W Dual AC inputs 139 ...

Страница 53: ...HPE 5930 4Slot TAA Chassis leakage current compliance UL60950 1 EN60950 1 IEC60950 1 GB4943 Melting current of power supply fuse 10 A 250 VAC 30 A 250 VDC Operating temperature 0 C to 45 C 32 F to 113 F Operating humidity 10 to 90 noncondensing Fire resistance compliance UL60950 1 EN60950 1 IEC60950 1 GB4943 ...

Страница 54: ...L No Yes Yes LSWM124XG2QFC No Yes Yes IMPORTANT The HPE 5930 32 QSFP HPE 5930 32 QSFP TAA HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switches can operate correctly with only one power supply You can install two power supplies on the switches for 1 1 redundancy The HPE 5930 4Slot HPE 5930 4Slot TAA switch can operate correctly with two power supplies You can install four power supplies on the sw...

Страница 55: ...P HPE 5930 32 QSFP TAA HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switches Fans Two 40 40 56 mm 1 57 1 57 2 2 in fans Fan speed 21000 R P M Max airflow 70 CFM Airflow direction Back to front Fans draw air from the power supply side to the network port side Input voltage 12 V Maximum power consumption 60 W Documentation reference HPE LSWM1HFANSC and LSWM1HFANSCB Fan Assemblies Installation LSWM1...

Страница 56: ...CB for the HPE 5930 4Slot HPE 5930 4Slot TAA switch Fans One 80 80 76 mm 3 14 3 14 2 99 in fan Fan speed 20000 R P M Max airflow 120 CFM Airflow direction From the port side to the power supply side Input voltage 12 V Maximum power consumption 57 W Documentation reference HPE LSWM1BFANSC LSWM1BFANSCB Fan Trays User Guide Interface modules The HPE 5930 2Slot 2QSFP HPE 5930 2Slot 2QSFP TAA switch pr...

Страница 57: ...e for the QSFP ports see QSFP port NOTE Only the SFP ports on the LSWM124XG2QFC interface module support the SFP FC 8G SW MM850 and SFP FC 8G LW SM1310 transceiver modules JH182A HPE 5930 24 port 10GBase T and 2 port QSFP with MacSec Module LSWM124XGT2Q 24 x 10 GE copper port 2 x QSFP port JH181A HPE 5930 24 port SFP and 2 port QSFP with MacSec Module LSWM124XG2Q 24 x SFP port 2 x QSFP port JH180A...

Страница 58: ...inal emulation program Management Ethernet port The switch has one management Ethernet port You can connect this port to a PC or management station for loading and debugging software or remote management Table 15 Management Ethernet port specifications Item Specification Connector type RJ 45 Connector quantity 1 Port transmission rate 10 100 1000 Mbps half full duplex Transmission medium and max t...

Страница 59: ...ransceiver modules available for the SFP ports Product code HPE description Central wavelength nm Connector Cable Fiber type and diameter µm Modal bandwidth MHz km Max transmissi on distance JD089B HPE X120 1G SFP RJ45 T Transceiver N A RJ 45 Category 5 twisted pair N A 100 m 328 08 ft JD118B HPE X120 1G SFP LC SX Transceiver 850 LC Multi mode 50 125 500 550 m 1804 46 ft 400 500 m 1640 42 ft Multi...

Страница 60: ... A 10 km 6 21 miles JG879A HPE X190 8G 4G 2G SFP LC Short Wave Transceiver 850 LC Multi mode 62 5 125 200 150 m 492 13 ft Multi mode 50 125 500 380 m 1246 72 ft 2000 500 m 1640 42 ft JG880A HPE X190 8G 4G 2G SFP LC Long Wave Transceiver 1310 LC Single mode 9 125 N A 10 km 6 21 miles Table 18 SFP network cables available for the SFP ports Product code HPE description Max transmission distance Data ...

Страница 61: ...QSFP TAA switches provide fixed QSFP ports The LSWM18QC LSWM124XGT2Q LSWM124XG2Q LSWM124XG2QL and LSWM124XG2QFC interface modules provide QSFP ports You can install 40G QSFP transceiver modules in Table 19 40G QSFP network cables in Table 20 and 40G QSFP to SFP network cables in Table 21 in the QSFP ports as needed Table 19 40G QSFP transceiver modules available for the QSFP ports Product code HPE...

Страница 62: ... to SFP cables available for the QSFP ports Product Code HPE description Cable length JG329A HPE X240 40G QSFP to 4x10G SFP 1m Direct Attach Copper Splitter Cable 1 m 3 28 ft JG330A HPE X240 40G QSFP to 4x10G SFP 3m Direct Attach Copper Splitter Cable 3 m 9 84 ft JG331A HPE X240 40G QSFP to 4x10G SFP 5m Direct Attach Copper Splitter Cable 5 m 16 40 ft Figure 60 40G QSFP network cable 1 Connector 2...

Страница 63: ...m Specification Connector type RJ 45 Port transmission rate 1 10 Gbps full duplex MDI MDI X autosensing Transmission medium and max transmission distance 55 m 180 45 ft over category 6 unshielded twisted pair cable 100 m 328 08 ft over category 6 shielded twisted pair cable 100 m 328 08 ft over category 6A or above twisted pair cable Compatible standards IEEE 802 3ab IEEE 802 3an To avoid interfer...

Страница 64: ...ort has a link and is operating at 1 Gbps Flashing yellow The port is sending or receiving data at 1 Gbps Off No transceiver module or cable has been installed or no link is present on the port QSFP port LED Each QSFP port has a status LED to show port operating status and activities Table 25 QSFP port LED description LED status Description Steady green A transceiver module or cable has been corre...

Страница 65: ... Status Description MGMT LINK ACT Steady green The management Ethernet port is operating at 10 100 1000 Mbps Flashing green The management Ethernet port is receiving or sending data Off The management Ethernet port is not connected 1 10GBase T autosensing Ethernet port LEDs Table 28 1 10GBase T autosensing Ethernet port LED description Status Description Steady green The port has a link and is ope...

Страница 66: ...air flows in through the air vents in the fan tray panel and the power supply panels circulates through the chassis and the power supplies and exhausts at the network port side as shown in Figure 62 When the LSWM1HFANSCB fan trays are used cool air flows in through the air vents in the network port side panel and the power supply panels circulates through the chassis and the power supplies and exh...

Страница 67: ...1BFANSC fan trays are used cool air flows in through the air vents in the fan tray panel and the power supply panels circulates through the chassis and the power supplies and exhausts at the network port side as shown in Figure 64 When LSWM1BFANSCB fan trays are used cool air flows in through the air vents in the network port side panel and the power supply panels circulates through the chassis an...

Страница 68: ...ure 65 Airflow through the HPE 5930 4Slot HPE 5930 4Slot TAA chassis with the LSWM1BFANSCB fan trays IMPORTANT The chassis and the power supplies use separate air aisles Make sure both aisles are not blocked ...

Страница 69: ... which you select at least one x y Asterisk marked square brackets enclose optional syntax choices separated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names...

Страница 70: ...rwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a wireless terminator unit Represents a wireless terminator Represents a mesh access point Represents omnidirectional signals Represents directional signals Represents a security product such as a firewa...

Страница 71: ...s provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates go to either of the following Hewlett Packard Enterprise Support Center Get connected with updates page www hpe com support e updates Software Depot website www hpe com support softwaredepot To view and u...

Страница 72: ...ht Remote Support not applicable to all devices www hpe com info insightremotesupport docs Customer self repair Hewlett Packard Enterprise customer self repair CSR programs allow you to repair your product If a CSR part needs to be replaced it will be shipped directly to you so that you can install it at your convenience Some parts do not qualify for CSR Your Hewlett Packard Enterprise authorized ...

Страница 73: ...d any errors suggestions or comments to Documentation Feedback docsfeedback hpe com When submitting your feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...