Current
11/6 A
Maximum power rating
1000 W
PoE power
816 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all modules
populated.
For Japan, the unit only operates at 200 V, 50 Hz,
and 6 A.
Safety
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal
line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3 V
Power frequency
magnetic field
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and
interruptions
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
Unmanaged power supply; provides information via LEDs or through port
interfaces of attached devices
Notes
Supported devices: HP Switch 2600-PWR Series, Switch 2610-PWR Series, and
Switch 5300xl Series
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (U9270E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U9271E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR854E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR855E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR857E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR858E)
3 Yr 6 hr Call-to-Repair Onsite (UW371E)
4 Yr 6 hr Call-to-Repair Onsite (UW372E)
5 Yr 6 hr Call-to-Repair Onsite (UW373E)
Refer to the HP website at:
www.hp.com/networking/services
for details on
the service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
QuickSpecs
HP 2610 Switch Series
Accessory Product Details
DA - 13032 Worldwide — Version 18 — November 11, 2013