Operating relative
humidity
15% to 95% @ 104°F (40°C), noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft. (3 km)
Acoustic
Power: 63.6 dB, Pressure: 56.6 dB; DIN 45635T.19
per ISO 7779
Electrical characteristics Maximum heat
dissipation
410 BTU/hr (432.55 kJ/hr), (switch-only BTU/hr:
410; combined max. PoE devices at 15.4
W: 2281 BTU/hr)
Voltage
100-127/200-240 VAC
Current
7.0/3.5 A
Maximum power rating
96 W
PoE power
406 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all modules
populated.
PoE Power is the power supplied by the internal
power supply, it is dependent on the type and
quantity of power supplies and may be
supplemented with the use of a External Power
Supply (EPS).
Power consumption: 96 W without PoE; 590 W
with PoE.
Safety
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5kV (signal
line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3V
Power frequency
magnetic field
IEC 61000-4-8; 1A/m,50 or 60 Hz
Voltage dips and
interruptions
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
Harmonics
EN 61000-3-2, IEC 61000-3-2
QuickSpecs
HP 2610 Switch Series
Technical Specifications
DA - 13032 Worldwide — Version 18 — November 11, 2013
Page 17