Section 6: Programming Basics
77
Keystrokes
Display
1
´
m
%
1.0000
R
1
and R
0
allocated for data
storage; R
2
to R
65
available for
programming and advanced
functions.
19
´
m%
19.0000
Original allocation: R
19
(R
.9
) and
below for data storage; R
20
, to
R
65
for programming and
advanced functions.
*
lm%
19.0000
Displays the current highest data
register.
The
m
and
W
(
memory status
)
functions are described in detail in
appendix C.
Keep in mind that an error message will result
(given the above memory
configuration)
if
1. You try to address a register higher than R
19
(R
.9
), which initially is
the highest register allocated to data storage (
Error 3
).
2. You have 322 occupied program bytes and try to load more program
lines (
Error 4
).
3. You try to run an advanced function with insufficient available
memory (
Error 10
).
Program Boundaries
End.
Not every program needs to end with a
n
or
¦
instruction. If
you are at the end of occupied program memory, there is an
automatic
n
instruction, so you do not need to enter one. This can save you one
line of memory. On the other hand, a program can ―end‖ by simply
transferring execution to another routine using
t
(section 7).
Labels.
Labels in a program (or subroutine) are markers telling the
calculator where to begin execution. Following an
´
label
or
G
label
instruction, the calculator will search downward in program memory for the
*
For memory allocation and indirect addressing, registers R
.0
through R
.9
are referred to as R
10
through R
19
.
Содержание HP-15C