25
The 650W AC power supply and 650W DC power supply removal procedure is the same on the HPE
5950 switches. The figures in this section use the HPE 5950 32QSFP28 switch as an example.
To remove a power supply:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Squeeze the tabs on the power cord connector with your thumb and forefinger, and pull the
connector out to remove the power cord, as shown in
3.
Hold the handle on the power supply with one hand, pivot the latch on the power supply to the
right with your thumb, and pull the power supply part way out of the slot, as shown in
4.
Supporting the power supply bottom with one hand, slowly pull the power supply out with the
other hand.
5.
Put the removed power supply in an antistatic bag for future use.
6.
If you are not to install a new power supply, install a filler panel in the slot to ensure good
ventilation in the switch.
Figure 32 Removing the DC power cord
(1) Press the tabs on the power cord connector with your thumb and forefinger
(2) Pull the power cord connector out
1
2