220
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 75 3.63 10.00 3.40 N/A
Low -5 2.97 0.50 -13.51 N/A
Table 39
Command output
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver module in the interface.
Temp.(°C)
Temperature in °C, accurate to 1°C.
Voltage(V)
Voltage in V, accurate to 0.01 V.
Bias(mA)
Bias current in mA, accurate to 0.01 mA.
RX power(dBm)
RX power in dBm, accurate to 0.01 dBm.
TX power(dBm)
TX power in dBm, accurate to 0.01 dBm.
display transceiver interface
Use
display transceiver interface
to display the key parameters of transceiver modules.
Syntax
display transceiver interface
[
interface-type interface-number
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type interface-number
: Specifies an interface by its type and number. If you do not specify this
option, the command displays the key parameters of every transceiver module.
Examples
# Display the key parameters of the transceiver module in interface FortyGigE 1/0/1.
<Sysname> display transceiver interface fortygige 1/0/1
FortyGigE1/0/1 transceiver information:
Transceiver Type : 40G_BASE_SR4_QSFP_PLUS
Connector Type : MPO
Wavelength(nm) : 850
Transfer Distance(m) : 100(OM3)
Digital Diagnostic Monitoring : YES
Vendor Name : HP
Ordering Name : JG325A