APPLy Output
The
APPLy
n subsystem commands provide the easiest method to output
voltages or currents.
/* Set channel 1 for 5.0 Volt output */
APPLy1:VOLTage 5.000
/* Channel is set to voltage output and 5.000 V applied */
/* Set channel 8 for 10 mA output */
APPLy8:CURRent 0.0100
/* Channel is set to current output and 10 mA applied */
The
APPLy
n subsystem outputs the voltage or current specified on the
channel specified immediately. The output relay for that channel is closed.
Other channel outputs and output states are not disturbed.
An
APPLy
n subsystem command performs several actions with a single
command. Each
APPLy
n command affects a single channel and:
–
Sets the channel output mode (voltage or current).
–
Sets the output value (volts or amps).
–
Enables the outputs (closes the output relay).
The output channel remains enabled, and outputs the last programmed
voltage or current value, unless you take explicit action to turn off the
output. For example, if you send two
APPLy
n commands to the same
channel, the first command sets an output value and closes the output relay.
The second command changes only the output value (since the relay is
already closed).
/* Set channel 1 for 5.0 Volt output */
APPLy1:VOLTage 5.000
/* Channel 1 is set to voltage output and 5.000 V applied */
/* Now set channel 1 for 6.0 Volt output */
APPLy1:VOLTage 6.000
/* Channel 1 is set to voltage output and 6.000 V applied */
The commands above will set a 5.000 Volt output on Channel 1, and then
set a 6.000 Volt output on channel 1. The output relay is not affected by the
second command.
Chapter 2
Programming Examples 45
Содержание E1418A
Страница 6: ...Notes 6 Contents HP E1418A 8 16 Channel D A Converter Module ...
Страница 10: ...Notes 10 HP E1418A User s Manual ...
Страница 12: ...12 HP E1418A User s Manual ...
Страница 105: ...TRIGger 105 HP E1418A SCPI Command Reference Chapter 3 ...
Страница 111: ...Notes HP E1418A Command Quick Reference 111 HP E1418A SCPI Command Reference Chapter 3 ...
Страница 135: ...135 HP E1418A Register Based Programming Appendix B ...
Страница 157: ...Notes 156 HP E1418A Error Messages Appendix C ...
Страница 164: ...Figure D 4 Resistance Calibration Connections CAL Appendix D Voltage Current Output Adjustment 163 ...
Страница 170: ...Notes Appendix D Voltage Current Output Adjustment 169 ...
Страница 174: ...Figure E 1 8 Channel Disassembly 172 Configuration and Disassembly Appendix E ...
Страница 175: ...Figure E 2 16 Channel Disassembly Appendix E Configuration and Disassembly 173 ...
Страница 177: ...Figure E 3 Plug on Channel Locations Figure E 4 Installing Plug on Modules Appendix E Configuration and Disassembly 175 ...
Страница 192: ...Notes 192 HP E1418A 8 16 Channel D A Converter Module Index ...