AK857B, AK857C).
Add Software:
HP Director Power Pack+ SAN Director Switch
TA640A
Fabric Vision, Fabric Watch, ISL Trunking, Extended Fabric and
Advanced Performance Monitoring
NOTE:
Optional software for only the SN8000B 4-Slot Director
(QK711A, QK711B) and the DC04 SAN Director (AR478A, AR478B)
NOTE:
Adaptive Networking and Server Application Optimization
features are included by default in the switch firmware (FOS 7.2.0a or
later) and do not require a separate license
HP StoreFabric B-series 8Gb and 16Gb SAN Director Switch Fabric
Vision LTU
TC513A
HP SN8000B Inter Chassis Link License
TC351A
Inter Chassis Links (ICLs) harness unused ports to connect the
switching backplane of one SN8000B Director with the switching
backplane of a second SN8000B Director. Each ICL connection is the
equivalent of 16 fixed speed 16Gbit/sec E_PORTs. This additional full
duplex connection provides up to an additional 2 Tbit/sec of
bandwidth and does not consume usable ports.
There is a common ICL POD (Ports on Demand) license between
SN8000 8-Slot and 4-Slot chassis. A single ICL POD license will
enable 16 QSFP ICLs or 1Tbps of bandwidth in both SN8000B 8-Slot
and 4-Slot SAN Director. A subsequent ICL POD license will enable an
additional 16 QSFP ICLs or 1Tbps in a SN8000B 8-Slot Director.
NOTE:
Each SN8000B SAN Director requires a license for ICL
connectivity (TC351A). Also requires QSFP (QK728A or H6Z76A) and
cables for ICL connectivity (QK729A or QK731A or H6Z30A).
A maximum of
four SN8000B
SAN Directors
may be connected
using ICL
connectivity
HP SN8000B 8-slot Director Enterprise Inter Chassis Link License
TC389A
HP SN8000B 4-slot Director Enterprise Inter Chassis Link License
TC390A
Inter Chassis Links (ICLs) harness unused ports to connect the
switching backplane of one SN8000B Director with the switching
backplane of a second SN8000B Director. Each ICL connection is the
equivalent of 16 fixed speed 16Gbit/sec E_PORTs. This additional full
duplex connection provides up to an additional 2 Tbit/sec of
bandwidth and does not consume usable ports.
From five to a
maximum of nine
SN8000B SAN
Directors may be
connected using
ICL connectivity
Each 8-slot and 4-slot SN8000B chassis require its own specified
license.
NOTE:
Each SN8000B SAN Director requires a license for ICL
connectivity (TC351A) as a prerequisite to the Enterprise Licenses
(TC389A and TC390A). Also requires QSFP (QK728A or H6Z76A) and
cables for ICL connectivity (QK729A or QK731A or H6Z30A).
QuickSpecs
HP SN8000B and DC SAN Director Family
Configuration Information
DA - 12993 Worldwide — Version 39 — December 20, 2013
Page 23