Chapter 9
Troubleshooting
69
IDE Device Does Not Work
If error messages display on the monitor indicating a failure of a IDE hard disk or
tape backup device, perform these checks:
1. Verify the power cable is securely connected to the drive, and the flat IDE
cable is securely connected to the drive and to the system board.
2. Ensure connector pins are not displaced or bent.
SCSI Device Does Not Work
If error messages display on the monitor indicating a failure of a SCSI hard disk
or tape backup device, perform these checks:
1. Verify the power cable is securely connected to the drive, and the flat cable
is securely connected to the drive and to the SCSI controller board.
2. Verify all SCSI devices have unique IDs.
3. Ensure the SCSI device is set for cable termination, not drive terminated.
HP SCSI drives come set for cable termination.
4. Verify the connector pins on the SCSI devices are not displaced or bent.
Installing a Replacement Battery
If your HP NetServer repeatedly loses its configuration or the processor clock
stops, you should replace the battery. To replace the battery, refer to the following
procedure.
WARNING
There is a danger of explosion if the battery is incorrectly
installed. For your safety, never attempt to recharge,
disassemble, or burn the old battery. Replace only with the
same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s
instructions.
1.
Power down the HP NetServer and unplug the power cord.
2.
Remove the NetServer cover and the cooling duct.
3.
Lay the NetServer on its side with the system board components facing up.