background image

 

Illustrated parts catalog  17 

Item 

Description 

Spare part 

number 

Customer self 

repair (on page 

5

) 

Front panel assembly 

621524-001 

Mandatory

1

 

LED panel 

621525-001 

Optional

2

 

Drive blank 

392613-001 

Mandatory

1

 

Drive drawer slide kit 

621526-001 

Mandatory

1

 

Drive drawer assembly 

621523-001 

Optional

2

 

10 

Drives*  

— 

— 

 

a) 146-GB, SFF, 10,000-rpm, SAS, dual-port 

507283-001 

Mandatory

1

 

 

b) 146-GB, SFF, 15,000-rpm, SAS, dual-port, enterprise 

512744-001 

Mandatory

1

 

 

c) 300-GB, SFF, 10,000-rpm, SAS, dual-port, enterprise 

507284-001 

Mandatory

1

 

 

d) 450-GB, SFF, 10,000-rpm, SAS, dual-port, enterprise 

581310-001 

Mandatory

1

 

 

* Not shown 

1

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be 

charged for the travel and labor costs of this service. 

2

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, 

however, you require that HP replace them for you, there may or may not be additional charges, depending on the type 

of warranty service designated for your product. 

3

No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that 

an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog. 

 

1

Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de 

remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. 

2

Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également 

conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces 

pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit. 

3

No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour 

que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces 

pièces sont identifiées par la mention “Non” dans le Catalogue illustré. 
 

1

Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la 

riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio. 

2

Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti 

progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese 

addizionali a seconda del tipo di garanzia previsto per il prodotto. 

3

No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la 

garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate 

da un “No” nel Catalogo illustrato dei componenti. 
 

1

Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie 

diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet. 

2

Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer 

Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei 

diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 

3

No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, 

muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. 

„Nein“ gekennzeichnet. 

 

Содержание D2200sb

Страница 1: ...diagnostic tools specifications and requirements for hardware components and software This guide is for an experienced service technician HP assumes you are qualified in the servicing of computer equipment trained in recognizing hazards in products and are familiar with weight and stability precautions Part Number 611258 002 April 2012 Edition 2 ...

Страница 2: ...ties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Windows is a U S registered trademark of Microsoft Corporation ...

Страница 3: ... access panel 26 Drive blank 27 Drive 28 FBWC capacitor pack 29 FBWC module 30 Front panel 31 LED panel 32 System board 33 Drive drawer 37 Drive drawer slide assemblies 39 Enclosure release latch assembly 41 Component identification 44 Front panel components 44 Front panel LEDs 45 SAS and SATA drive bay numbers 46 SAS and SATA drive LEDs 46 SAS and SATA drive LED combinations 46 Diagnostic tools 4...

Страница 4: ...Contents 4 ...

Страница 5: ...n will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is required to return the defective part to HP you must ship the defective part back to HP within a defined period of time normally five 5 business days The defective part must be returned with the associated documentation in the pro...

Страница 6: ...ine la société de courses ou le transporteur à utiliser Pour plus d informations sur le programme CSR de HP contactez votre Mainteneur Agrée local Pour plus d informations sur ce programme en Amérique du Nord consultez le site Web HP http www hp com go selfrepair Service de garantie pièces seules Votre garantie limitée HP peut inclure un service de garantie pièces seules Dans ce cas les pièces de ...

Страница 7: ... Self Repair um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen Wenn HP oder ein HP Servicepartner bei der Diagnose feststellt dass das Produkt mithilfe eines CSR Teils repariert werden kann sendet Ihnen HP dieses Bauteil zum Austausch direkt zu CSR Teile werden in zwei Kategorien unterteilt Zwingend Teile für die das Customer Self Repair Verfa...

Страница 8: ...tegorías Obligatorio componentes para los que la reparación por parte del usuario es obligatoria Si solicita a HP que realice la sustitución de estos componentes tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio Opcional componentes para los que la reparación por parte del usuario es opcional Estos componentes también están diseñados para que puedan ser r...

Страница 9: ...orieën CSR onderdelen Verplicht Onderdelen waarvoor reparatie door de klant verplicht is Als u HP verzoekt deze onderdelen voor u te vervangen worden u voor deze service reiskosten en arbeidsloon in rekening gebracht Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te v...

Страница 10: ...ependendo do tipo de serviço de garantia destinado ao produto OBSERVAÇÃO Algumas peças da HP não são projetadas para o reparo feito pelo cliente A fim de cumprir a garantia do cliente a HP exige que um técnico autorizado substitua a peça Essas peças estão identificadas com a marca No Não no catálogo de peças ilustrado Conforme a disponibilidade e o local geográfico as peças CSR serão enviadas no p...

Страница 11: ...Customer self repair 11 No caso desse serviço a substituição de peças CSR é obrigatória Se desejar que a HP substitua essas peças serão cobradas as despesas de transporte e mão de obra do serviço ...

Страница 12: ...Customer self repair 12 ...

Страница 13: ...Customer self repair 13 ...

Страница 14: ...Customer self repair 14 ...

Страница 15: ...Customer self repair 15 ...

Страница 16: ...s HP PartSurfer website http partsurfer hp com search aspx HP Parts Store website http h20141 www2 hp com Hpparts Default aspx Item Description Spare part number Customer self repair on page 5 1 FBWC capacitor pack 571437 001 Mandatory1 2 System board 621520 001 Optional2 3 FBWC module 621521 001 Mandatory1 4 Enclosure release latch 621522 001 Mandatory1 ...

Страница 17: ...on vous être facturée selon le type de garantie applicable à votre produit 3 No Non Certaines pièces HP ne sont pas conçues pour permettre au client d effectuer lui même la réparation Pour que la garantie puisse s appliquer HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé Ces pièces sont identifiées par la mention Non dans le Catalogue illustré 1 Mandatory Obbligatori...

Страница 18: ...w rekening 2 Optional Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product 3 No Nee Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door...

Страница 19: ...Illustrated parts catalog 19 ...

Страница 20: ...tainers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly grounded when touching a static sensitive component or assembly Symbols on equipment The following symbols may be placed on equipment to indicate the presen...

Страница 21: ...k of injury from electric shock remove all power cords to completely disconnect power from the system Storage blade warnings and cautions WARNING To reduce the risk of shock or injury from high current electrical energy do not remove the storage blade access panel and then install the storage blade into the enclosure WARNING To reduce the risk of personal injury from hot surfaces allow the drives ...

Страница 22: ...storage blade WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the storage blade before beginning any installation procedure Improper grounding can cause ESD To remove the component 1 Identify the proper storage blade 2 Power down the pa...

Страница 23: ...lade on a flat level work surface Avoiding equipment damage and data loss To avoid possible equipment damage and data loss when performing service on the storage blade remove the following components and store them in a static free environment any time the access panel must be removed Remove the drives on page 24 Remove the FBWC module on page 25 ...

Страница 24: ...ither a component or a blank CAUTION Thermal regulation is maintained only when the drive drawer is closed The drive temperature alarm is triggered under the following conditions A slow beep and flash 1 every 5 seconds indicate that the drive drawer is open The drives are not fully protected by system air flow A fast beep and flash 2 per second To avoid drive damage or data loss and storage blade ...

Страница 25: ...und the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage To remove the component 1 Back up all data on the storage blade 2 Power down the partner server bla...

Страница 26: ...CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage To remove the component 1 Power down the partner server blade on page 22 2 Remove the storage blade on page 22 3 Press the access panel release button 4 Slide the access panel toward the rear of th...

Страница 27: ...al components properly ground the storage blade before beginning any installation procedure Improper grounding can cause ESD CAUTION To prevent improper cooling and thermal damage do not operate the storage blade or the enclosure unless the first drive bay is populated with a drive and drive bays 2 and 3 and all device bays are populated with either a component or a blank CAUTION Thermal regulatio...

Страница 28: ...ed with a drive and drive bays 2 and 3 and all device bays are populated with either a component or a blank CAUTION Thermal regulation is maintained only when the drive drawer is closed The drive temperature alarm is triggered under the following conditions A slow beep and flash 1 every 5 seconds indicate that the drive drawer is open The drives are not fully protected by system air flow A fast be...

Страница 29: ...rives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and improper coolin...

Страница 30: ...t surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airfl...

Страница 31: ...ble spool are not shown for clarity IMPORTANT To avoid possible damage to the storage blade be sure that the FBWC module is fully seated before installing the retaining screw To replace the component reverse the removal procedure Front panel WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them ...

Страница 32: ...nel To replace the component reverse the removal procedure LED panel WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the storage blade before beginning any installation procedure Improper grounding can cause ESD To remove the component ...

Страница 33: ...properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage To remove the component 1 Back up all data on the storage blade 2 Power down the partne...

Страница 34: ... drive drawer 9 Remove the capacitor cover IMPORTANT The capacitor cover screw is longer than the remaining system board screws CAUTION The pass through cable is under tension Hold the end of the cable firmly when removing and guide the cable back to the coiled position in the chassis ...

Страница 35: ...ble from the drive drawer CAUTION To avoid damage to the cable spool guides do not pull them outwards 11 To remove the pass through cable from the carrier pull the cable spool guides toward you with both index fingers and then push the cable spool away from you with both thumbs ...

Страница 36: ...ugh cable in the carrier Be sure to route the cable under the chassis support rail 3 Install the pass through board and cable in the drive drawer 4 Install the capacitor cover 5 Install the pass through cable cover on the drive drawer 6 Install the FBWC module 7 Install the FBWC capacitor pack 8 Install the access panel 9 Install all drives ...

Страница 37: ...To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the storage blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage ...

Страница 38: ...ough cable cover from the drive drawer CAUTION The pass through cable is under tension Hold the end of the cable firmly when removing and guide the cable back to the coiled position in the chassis 7 Remove the pass through board and cable from the drive drawer ...

Страница 39: ...age to electrical components properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage To remove the component 1 Back up all data on the storage ...

Страница 40: ...Removal and replacement procedures 40 a Top slide assembly b Bottom slide assembly 8 Remove the slide assemblies from the chassis ...

Страница 41: ...aces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD CAUTION Do not operate the storage blade with the access panel open or removed Operating the storage blade in this manner results in improper airflow and...

Страница 42: ...age 22 3 Remove the storage blade on page 22 4 Remove all drives Remove the drives on page 24 5 Remove the access panel on page 26 6 Remove the drive drawer Drive drawer on page 37 7 Remove the bottom drive drawer slide assembly from the chassis You do not need to remove the remaining slide assembly from the chassis or either slide assembly from the drive drawer ...

Страница 43: ...Removal and replacement procedures 43 8 Remove the failed enclosure release latch assembly To replace the component reverse the removal procedure ...

Страница 44: ...ification Front panel components Item Description 1 Product information tag 2 LED panel 3 Drive drawer release latch 4 Drive drawer handle 5 Storage blade locking lever Removing the storage blade from the enclosure removes power from the drives ...

Страница 45: ...een Drive installed Flashing green Drive activity established Flashing green slow Drive rebuilding 5 Drawer temp LED Off Drawer is closed or thermal shutdown has occurred Flashing amber 1 per 5 seconds Drawer is open Flashing amber 2 per second Drives have reached near critical temperatures The system health LED flashes amber when the storage blade establishes a connection with the enclosure eithe...

Страница 46: ...retation On off or flashing Alternating amber and blue The drive has failed or a predictive failure alert has been received for this drive it also has been selected by a management application On off or flashing Steadily blue The drive is operating normally and it has been selected by a management application On Amber flashing regularly 1 Hz A predictive failure alert has been received for this dr...

Страница 47: ...rive Removing a drive may terminate the current operation and cause data loss The drive is rebuilding erasing or it is part of an array that is undergoing capacity expansion or stripe migration Flashing irregularly Amber flashing regularly 1 Hz The drive is active but a predictive failure alert has been received for this drive Replace the drive as soon as possible Flashing irregularly Off The driv...

Страница 48: ... Foundation suite for ProLiant Integrated Management Log Gen8 servers The IML records hundreds of events and stores them in an easy to view form The IML timestamps each event with 1 minute granularity You can view recorded events in the IML in several ways including the following From within HP SIM From within operating system specific IML viewers o For Windows IML Viewer o For Linux IML Viewer Ap...

Страница 49: ... limited by the type and number of options installed Non operating 9144 m 30 000 ft Temperature ratings shown are for sea level An altitude derating of 1 C per 300 m 1 8 F per 1 000 ft to 3048 m 10 000 ft is applicable No direct sunlight is allowed The upper limit may be limited by the type and number of options installed Storage maximum humidity of 90 is based on a maximum temperature of 45 C 113...

Страница 50: ...LI Command Line Interface CSR Customer Self Repair FBWC flash backed write cache HP SIM HP Systems Insight Manager iLO 2 Integrated Lights Out 2 IML Integrated Management Log SAS serial attached SCSI SATA serial ATA SFF small form factor SIM Systems Insight Manager UID unit identification ...

Страница 51: ...oviding documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback ...

Страница 52: ...ront panel components 45 front panel LEDs 46 H health LEDs 46 I illustrated parts catalog 16 installing the access panel 27 Integrated Management Log IML 49 L LED panel 33 LED health 46 LED internal health 46 LEDs 45 47 LEDs drive 47 48 LEDs front panel 45 46 M management tools 49 P part numbers 16 powering down 22 preparation procedures 22 24 R removal and replacement procedures 20 removing the a...

Страница 53: ...Index 53 T tools 20 49 U UID LED 46 W warnings 21 warranty 5 ...

Отзывы: