D–20
319865-008
Service Reference Guide, d300, dx6050
Troubleshooting Without Diagnostics
Solving Memory Problems
Ä
CAUTION:
For those systems that support ECC memory, HP does not support mixing ECC and non-ECC
memory. Otherwise, the system will not boot the operating system.
Solving Memory Problems
Problem
Cause
Solution
System will not boot or
does not function properly
after installing additional
memory modules.
Memory module is not
the correct type or
speed or the new
memory module is not
seated properly.
Replace module with the correct
industry-standard device for the
computer.
On some models, ECC and non-ECC
memory modules cannot be mixed.
Out of memory error.
Memory configuration
may not be set up
correctly.
Use the Device Manager to check
memory configuration.
You have run out of
memory to run the
application.
Check the application
documentation to determine the
memory requirements.
Memory count during POST
is wrong.
The memory modules
may not be installed
correctly.
Check that the memory modules
have been installed correctly and
that proper modules are used.
Insufficient memory error
during operation.
Too many Terminate
and Stay Resident
programs (TSRs) are
installed.
Delete any TSRs that you do
not need.
You have run out of
memory for the
application.
Check the memory requirements for
the application or add more
memory to the computer.
Power LED flashes Red five
times, once every second,
followed by a two second
pause, and the computer
beeps five times.
Memory is installed
incorrectly or is bad.
1. Reseat DIMMs.
2. Replace DIMMs one at a time to
isolate the faulty module.
3. Replace third-party memory
with HP memory.
4. Replace the system board.
Содержание Compaq d300 Series
Страница 2: ......
Страница 10: ...viii 319865 008 Service Reference Guide d300 dx6050 Contents ...
Страница 32: ...2 20 319865 007 Service Reference Guide d300 Setup Utilities and Diagnostics Features ...
Страница 64: ...4 12 319865 008 Service Reference Guide d300 dx6050 Serial and Parallel ATA Drive Guidelines and Features ...
Страница 178: ...8 36 319865 008 Service Reference Guide d300 dx6050 Removal and Replacement Procedures Desktop DT Chassis ...
Страница 196: ...C 8 319865 008 Service Reference Guide d300 dx6050 POST Error Messages ...
Страница 222: ...D 26 319865 008 Service Reference Guide d300 dx6050 Troubleshooting Without Diagnostics ...
Страница 226: ...E 4 319865 008 Service Reference Guide d300 dx6050 Memory ...
Страница 230: ...F 4 319865 008 Service Reference Guide d300 dx6050 System Board and Riser Board Reference Designators ...
Страница 238: ...Index 8 319865 008 Service Reference Guide d300 dx6050 Index ...