Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
(V5.0A and later)
Each system node in the cluster requires a TruCluster Server license (QL-6BRAC-AA)
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
(V4.0G and earlier)
Requires a minimum of Tru64 UNIX V4.0F with TruCluster V1.6 or later
Each system node in the cluster requires a TruCluster Production Server
(QB-3RLAE-AA) or TruCluster MEMORY CHANNEL software license (QB-4ZCAE-AA)
TruCluster MEMORY CHANNEL license (QB-4ZCAG-AA), normally used for high performance technical
computing applications, not required if systems have a TruCluster Production Server license (QB-3RLAE-
AA)
OpenVMS Systems
OpenVMS Systems
OpenVMS Systems
OpenVMS Systems
Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license (QL-MUZAC-AA)
Configuring Information
Configuring Information
Configuring Information
Configuring Information
Up to two PCI to System Area Network adapters (CCMAB-AA) are supported in a single system
Two-node clusters can be configured by ordering a CCMAB-AA for each node and one BN39B-04 or
BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
For a two-node cluster that will not need to be rebooted when adding additional members, order one
CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub
for the cluster.
For three- or four- node clusters, order one CCMAB-AA adapter and one
BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster
CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight
system nodes can be achieved by adding up to four additional CCMLB-AA line cards
If nodes must be separated by a distance longer than standard copper cables allow the CCMFB option
converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic
cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers
connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The
connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option
requires a second PCI slot in the system from which it draws power only. It is normally connected to the
corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the
CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four
radial fiber optic connections.
If two CCMAB-AA's are configured in each system, a second CCMHB-AA is required.
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
Controller
Controller
Controller
Controller
PCI System Area Network Controller, maximum two
CCMAB-AA
System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan,
and US operations- for other regions, order appropriate power cord from list below
CCMHB-AA
Expansion line card for CCMHB hub
CCMLB-AA
1-meter cable for CCMAB and CCMHB
BN39B-01
4-meter cable for CCMAB and CCMHB
BN39B-04
10-meter cable for CCMAB and CCMHB
BN39B-10
Copper-to-single mode fiber optic converter – 5V (clock not affected)
CCMFB-AA
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
Power Cords
Power Cords
Power Cords
Power Cords
Australia, New Zealand (103541-011)
BN19H-2E
Central Europe
BN19C-2E
Denmark (103541-481)
BN19K-2E
Egypt, India (103541-AR1)
BN19S-2E
Ireland, United Kingdom
BN19A-2E
Israel
BN18L-2E
Italy (103541-461)
BN19M-2E
Switzerland (103541-511)
BN19E-2E
QuickSpecs
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
Options
DA - 10445 North America — Version 37 — October 24, 2003
Page 30