DC Power Input for DC-Input Power Supply Cage
A DC power terminal block is provided at the rear of the DC-input power supply cage. It is
recommended to use appropriately sized power wire and DC mains.
OM13119
+
+
-
-
Figure 29. DC Power Input Connector
The terminal block will accept standard terminal lugs size Newark
†
stock # 81N1501 type
CRS-T0-1406-HT that accept 14 AWG wire gauge. The width (W in Figure 30) of the lug can be
no larger than 0.25 inches.
Figure 30. DC Power Terminal Lug
To connect the earth ground or power conductors to the chassis studs:
1. Place a #8-32 nut on the chassis stud and tighten to 10 in-lb.
2. Place the earth ground or power wire terminal lug on the chassis stud.
3. Place another #8-32 nut on the chassis stud so that the earth ground wire terminal is between
the two nuts and tighten the second nut to 10 in-lb.