116
cc2300 Carrier Grade Server Product Guide
Table 22. POST Codes and Error Messages (continued)
Error Code
Error Message
Pause on Boot
8281
Right Coherency Filter failed data test
No
8290
Left Coherency Filter failed address test
No
8291
Right Coherency Filter failed address test
No
8292
Speed mismatched processors have been disabled
No
8293
Coherency Filter size mismatch
No
8306
Please power down the system and exchange DIMM1 and DIMM2,
system halted
Yes, system halted
8307
Please power down the system and exchange DIMM1 and DIMM3,
system halted
Yes, system halted
8308
Please power down the system and exchange DIMM2 and DIMM3,
system halted
Yes, system halted
8309
Double data row DIMM detected in DIMM2 socket, system halted
Yes, system halted
830A
Double data row DIMM detected in DIMM3 socket, system halted
Yes, system halted
8400
Switch fault on PCI hot-plug
No
8401
Hot plug switches overridden by jumper or setup
No
8402
Hot plug power-up sequence did not complete
No
8500
Memory not detected in location: XX, XX, XX …
Yes
8501
Memory SPD error in location: XX, XX, XX …
Yes
8502
Incorrect memory type in location: XX, XX, XX …
Yes
8503
Incorrect memory speed in location: XX, XX, XX …
Yes
8504
Non-Specific memory error in location: XX, XX, XX …
Yes
Содержание cc2300
Страница 1: ...Hewlett Packard cc2300 Carrier Grade Server Product Guide Document Release Date March 2003 ...
Страница 12: ......
Страница 38: ......
Страница 40: ......
Страница 60: ......
Страница 88: ......
Страница 90: ...90 cc2300 Carrier Grade Server Product Guide Figure 26 Front Panel Board Removal ...
Страница 106: ......
Страница 118: ......
Страница 130: ...130 cc2300 Carrier Grade Server Product Guide ...