2-10
www.hp.com
HP PC Blade Switch CLI Reference Guide
802.1x Commands
dot1x timeout supp-timeout
The
dot1x timeout supp-timeout
Interface Configuration mode command sets the time for the
retransmission of an Extensible Authentication Protocol (EAP)-request frame to the client. To
return to the default configuration, use the
no
form of this command.
Syntax
dot1x timeout supp-timeout
seconds
no dot1x timeout supp-timeout
Parameters
■
seconds —
Time in seconds that the device waits for a response to an EAP-request frame
from the client before resending the request. (Range: 1-65535 seconds)
Default Configuration
Default timeout period is 30 seconds.
Command Mode
Interface configuration (Ethernet) mode
Command Usage
The default value of this command should be changed only to adjust for unusual circumstances,
such as unreliable links or specific behavioral problems with certain clients and authentication
servers.
Example
The following command sets the timeout period before retransmitting an EAP-request frame to
the client to 3600 seconds.
Console(config-if)#
dot1x timeout supp-timeout
3600
Содержание Bc1500 - BladeSystem - Blade PC
Страница 44: ...2 24 www hp com HP PC Blade Switch CLI Reference Guide 802 1x Commands ...
Страница 90: ...5 22 www hp com HP PC Blade Switch CLI Reference Guide Address Table Commands ...
Страница 140: ...8 24 www hp com HP PC Blade Switch CLI Reference Guide Ethernet Configuration Commands ...
Страница 150: ...9 10 www hp com HP PC Blade Switch CLI Reference Guide GVRP Commands ...
Страница 160: ...10 10 www hp com HP PC Blade Switch CLI Reference Guide IGMP Snooping Commands ...
Страница 176: ...11 16 www hp com HP PC Blade Switch CLI Reference Guide IP Addressing Commands ...
Страница 192: ...13 10 www hp com HP PC Blade Switch CLI Reference Guide Line Commands ...
Страница 200: ...14 8 www hp com HP PC Blade Switch CLI Reference Guide Management ACL Commands ...
Страница 206: ...15 6 www hp com HP PC Blade Switch CLI Reference Guide PHY Diagnostics Commands ...
Страница 214: ...17 4 www hp com HP PC Blade Switch CLI Reference Guide Port Monitor Commands ...
Страница 270: ...20 18 www hp com HP PC Blade Switch CLI Reference Guide RMON Commands ...
Страница 360: ...24 16 www hp com HP PC Blade Switch CLI Reference Guide Syslog Commands ...