System Power-Up
4-19
OpenVMS
Graphical Interface
1. From the Main Menu, select
IVP
, Load Script
and
select
Long IVP (the IVP tests will then load into the
Q-VET process window).
2. Click
the
Start All button to begin IVP testing.
Command-Line
Interface
$ vet /int=char
Q-Vet_setup> execute ivp.vms
Q-Vet_setup> start
Note that commands are case sensitive.
NOTE: A quick IVP script is provided for a simple verification of device setup.
It is selectable from the GUI IVP menu, and the script is called
.Ivp_short.scp (ivp_short.vms). This script will run for 15 minutes
and then terminate with a Summary log. The short script may be run
prior to the Long IVP script if desired, but not in place of the Long IVP
script, which is the full IVP test.
The Long IVP will run until the slowest device has completed one pass
(typically 4 to 10 hours). This is called a Cycle of Testing.