Install the SCSI I/O modules

1.

Slide the module into the chassis SCSI I/O slot until the latch clicks

into place.

15647

2.

Install all other SCSI I/O modules or blanks.

Install the fan modules

1.

Slide the module into the chassis fan slot until the latch clicks into

place.

15648

2.

Install the other fan module.

Install the Fibre Channel (or Ethernet) modules

1.

Slide the module into the chassis network interconnect slot until

the latch clicks into place.

NOTE:

The following illustration demonstrates installing a Fibre Channel

I/O module in the chassis. For the MSA1510i, the 2–Port

Ethernet iSCSI I/O module is in this slot.

15502

2.

Install the other I/O module or blank.

Completing the replacement

1.

Reconnect the AC power cords to the MSA.

2.

Reconnect the SCSI and Fibre Channel (or Ethernet) cables to the

MSA chassis.

IMPORTANT:

When connecting SCSI and Fibre Channel (or Ethernet) cables,

make sure that the connections are secure and are connected

in the same con

fi

guration as before the replacement. Do not

make any con

fi

guration changes at this time. If the con

fi

guration

differs, the MSA will not properly see and identify the storage.

3.

Start up the following devices and wait for them to complete their

startup routines:
• Uninterruptible Power Supplies
• Network switches
• External storage enclosures

4.

Start up the MSA1500/1510i.

5.

Read the controller LCD panel messages during the MSA startup

routine.
• If the following messages are displayed, the serial number

of the original chassis was automatically transferred to the

replacement chassis.

SPARE CHASSIS DETECTED

CHASSIS SERIAL NUMBER FLASHED UPDATED

IMPORTANT:

If these messages are displayed, the MSA1500/1510i will

automatically restart.

• If the following message is displayed, it may safely be ignored.

I2C WRITE FAILURE

• When the following message is displayed, the startup routine is

complete.

STARTUP COMPLETE

Verifying proper operation

After replacing the failed chassis, verify that:

No error messages are displayed on the controller LCD panels.

The chassis Power LED is solid green.

The chassis Heartbeat LED is blinking green.

LEDs on each MSA module are showing a healthy status.

IMPORTANT:

If

CHASSIS MISMATCH POWER OFF AND FIX

is displayed

on the controller LCD panel, persistent data stored on all of the

hard drives does not match. The original con

fi

guration was

changed or startup procedures were followed incorrectly. Power

off the MSA1500/1510i, correct any con

fi

guration changes, and

repeat the power-on sequence.

Page 4

Содержание AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive

Страница 1: ...t Ethernet I O module Illustrations in this document show the Fibre Channel I O module of an MSA1500 If you are replacing an MSA1510i chassis your module will look different Before you begin Read the following cautions and notices before replacing the chassis CAUTION Parts can be damaged by electrostatic discharge Use proper anti static protection For additional information see the documentation t...

Страница 2: ...assis NOTE The following illustration demonstrates removing a Fibre Channel I O module from the MSA1500 chassis For the MSA1510i the 2 Port Ethernet iSCSI I O module is in this slot 2 1 15498 2 Remove the other I O module or blank Remove the fan modules 1 Lift the port colored latch and pull the module out of the chassis 2 1 15643 2 Remove the other fan module Remove the SCSI I O modules 1 Lift th...

Страница 3: ...uct label is located on the side of the MSA chassis 15641 Install the MSA in the rack 1 Slide the MSA into the rack and then secure the MSA to the front of the rack using the thumbscrews on the front of the MSA 2 Attach the decorative bezel on the front of the MSA by aligning the pins and retaining clips on the back of bezel with the corresponding locations on the front of the chassis Then with ev...

Страница 4: ...tart up the following devices and wait for them to complete their startup routines Uninterruptible Power Supplies Network switches External storage enclosures 4 Start up the MSA1500 1510i 5 Read the controller LCD panel messages during the MSA startup routine If the following messages are displayed the serial number of the original chassis was automatically transferred to the replacement chassis S...

Страница 5: ... must ship the defective part back to HP within a defined period of time normally five business days The defective part must be returned with the associated documentation in the provided shipping material Failure to return the defective part may result in HP billing you for the replacement For details follow the return instructions shipped with the replacement chassis Page 5 ...

Отзывы: