background image

2

6. Attach the SCSI Channel A connector (previously removed from the system board connector) to the A1 Channel of 
the PCI-X RAID card.

7. Route the SCSI cable around the heatsink on the PCI-X RAID card and under the edge of the PCI slot 2 connector. 
See figure 2.

8. Continue routing the cable parallel to the connector edge of the PCI cage. 

9. Reinstall any accessory card previously removed from PCI slot 2.

10. Install the PCI cage into the server chassis.

11. Route the SCSI cable under the power supply bracket as shown in figure 3.

Figure 3.  Route Cable under Power Supply Bracket

12. Route the SCSI cable through the access slot of the fan assembly to the connector on the SCSI backplane.

See figure 4.

Figure 4.  Cable Routing at SCSI Cage 

13. Complete the installation by following the instructions provided in the 

hp integrity rx1600 Operation and 

Maintenance Guide

 for closing up the server, installing in a rack, and powering-up. To enable RAID refer to the 

A9890A documentation.

NOTE

The SCSI cable should be routed over the IDE cable if the IDE cable is present.

CAUTION

Do not block the airflow of the chassis fans. Reduced airflow may cause overheating.

Power Supply 

Bracket

Route over IDE 

cable (if present)

Do not block fans

Отзывы: