314
To do…
Use the command…
Remarks
Configure the startup query
interval
startup-query-interval
interval
Optional
By default, the startup query
interval is 1/4 of the “MLD query
interval”.
Configure the startup query count
startup-query-count
value
Optional
By default, the startup query count
is set to the MLD querier’s
robustness variable.
Configure the MLD query interval
timer query
interval
Optional
125 seconds by default.
Configure the maximum response
delay for MLD general query
messages
max-response-time
interval
Optional
10 seconds by default
Configure the MLD last listener
query interval
last-listener-query-interval
interval
Optional
1 second by default
Configure the MLD other querier
present interval
timer other-querier-present
interval
Optional
By default, the other querier
present interval is determined by
the formula: Other querier present
interval (in seconds) = [ MLD
query interval ] × [ MLD querier’s
robustness variable ] + [
maximum response delay for MLD
general query ] /2.
Configuring MLD query and response parameters on an interface
Follow these steps to configure MLD query and response parameters on an interface:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter interface view
interface
interface-type interface-
number
—
Configure the MLD querier’s
robustness variable
mld robust-count
robust-value
Optional
2 times by default
Configure the startup query
interval
mld startup-query-interval
interval
Optional
By default, the startup query
interval is 1/4 of the “MLD query
interval”.
Configure the startup query count
mld startup-query-count
value
Optional
By default, the startup query count
is the same as the robustness
variable.
Configure the MLD query interval
mld timer query
interval
Optional
125 seconds by default.
Содержание A5500 EI Switch Series