3
Also
in
the
rst
block
is
the
Measurement
type
,
this
describes
the
channel
used,
and
how
the
readings
were
made
,
for
example
,
Ch.
A
(Absolute)
when
absolute
readings
were
made
in
channel
A,
or
B
/
REF
when
relative
readings
were
made
in
channel
B
.
The
last
element
in
the
rst
block
is
the
comment.
The
message
set
up
in
the
Plot
application
is
here
on
the
printout.
The
second
block
of
data
contains
the
parameters
set
in
Measure
mode
.
These
are
T
avg ,
the
averaging
time
,
Cal
Fact
the
calibration
factor
,
Wvl ,
the
wavelength,
and
Reference ,
the
reference
power-level.
The
reference
is
not
included
when
the
samples
were
taken
as
absolute
values
.
The
third
block
of
data
contains
the
parameters
set
in
Menu
mode
for
the
application.
These
are
T
total,
the
period
for
which
the
application
was
taking
samples
,
and
Samples ,
the
number
of
samples
taken.
The
total
time
for
the
logging
application
consists
of
the
averaging
time
and
the
time
to
process
the
sample
.
That
is
,
a
sample
is
only
taken
after
the
previous
sample
has
been
taken
and
processed.
On
the
printout,
the
total
time
given
for
the
logging
application
includes
both
the
averaging
and
the
processing
time
.
The
nal
block
of
data
contains
statistics
based
on
the
samples
taken.
These
are
Max ,
the
maximum
power-level
sampled,
Min
the
minimum
power-level
sampled,
Diff ,
the
dierence
between
the
minimum
and
maximum
power-levels
sampled,
and
Avg ,
the
mean
average
of
the
samples
.
Note
If
the
samples
are
taken
in
dB
or
dBm,
Avg
is
the
mean
average
of
these
logarithmic
values
.
If
the
samples
are
taken
in
W
atts
,
Avg
is
the
mean
average
of
the
linear
values
.
The
printer
now
outputs
a
graph
with
the
same
format
as
the
plot
(see
Figure
3-7).
That
is
,
The
quantity
on
the
y-axis
of
the
graph
is
power
.
The
units
can
be
dBm,
dB
,
or
W
atts
.
The
quantity
on
the
x-axis
of
the
graph
is
time
for
the
graph
of
samples
from
a
Stability
or
a
Logging
application,
or
the
number
of
samples
for
the
graph
from
a
Manual
Logging
application.
The
units
of
time
can
be
seconds
,
minutes
or
hours
.
3-24
Local
Control
-
Menu
Mode
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 8153A
Страница 29: ...Index Contents 11 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 62: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 96: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 116: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 132: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 154: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 184: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 192: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 228: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 240: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...