3-6
Quality
Electromagnetic Compatibility Programs
Table 3-7 summarizes the magnetic field immunity tests.
Line Transients Immunity/Susceptibility Test Suite
This section summarizes the Line Transients Immunity/Susceptibility Test Suite.
NOTE:
All tests in this suite were performed while the product was operating.
Table 3-8 summarizes the electrical fast transients test.
Table 3-9 summarizes the surge transients tests.
Table 3-10 summarizes the conducted immunity test.
Table 3-11 summarizes the line sag test.
Table 3-7
Magnetic Field Immunity
Standard
Level
HP Standard 765.001
317 A/m
IEC 801-8 level 5
100 A/m
Table 3-8
Electrical Fast Transients
Standard
Level
prEN55024-4 (ISM)
2 KV mains, 1 KV I/O ports
Table 3-9
Surge Transients
Standard
Level
HP Standard 765.003
1 KV DM/CM high energy transient
HP Standard 765.003
1 KV DM/CM low energy transient
HP Standard 765.003
3 KV peak DM/CM low energy ring wave
IEC 801-5 level 3
1 KV DM, 2KV CM
Table 3-10
Conducted Immunity
Standard
Level
EN55082-1, IEC801-6, level 2
3 V rms
Table 3-11
Line Sag
Standard
Level
HP Standard 765.003
500 ms, 33% sag
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com