Installing the Target
System Probe
1. Set up the switches inside the emulation pod. When you are
using the HP 64146-61002 emulation pod, refer to the 7750/51
Series Emulation Pod User’s Guide. When you are using an
other emulation pod, refer to the manual provided with your
emulation pod.
2. Remove the 7750/51 Series microprocessor from the target
system socket. Note the location of pin 1 on the processor and
on the target system socket.
3. Store the microprocessor in a protected environment (such as
antistatic foam).
4. Install the target system probe into the target system
microprocessor socket. (See figure 3-1.)
5. Turn on power of your target system, and then, turn on the
emulator.
Figure 3-1. Installing the Probe to LCC80 Socket
In-Circuit Emulation 3-3