Figure 42 VMware configuration
.
5 SAN switch 1
1 Network interconnection
6 SAN switch 2
2 Single HBA server
7 Controller A
3 Dual HBA server
8 Controller B
4 Management server
Failure scenarios
HP-UX
Table 27 HP-UX failure scenarios.
Failure effect
Fault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.
Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk
corrupted, need mkfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk
corrupted, need mkfs disk.
Controller failure