Example: power-over-ethernet threshold option
Executing the following command sets the global notification threshold to 70% of available PoE
power:
ProCurve(config)# power-over-ethernet threshold 70
COMMAND DETAILS
pre-std-detect
■
[no] power-over-ethernet pre-std-detect
Usage: [NO] power-over-ethernet pre-std-detect
Description: Detect and power pre-802.3af-standard devices. This is enabled
by default.
redundancy
■
[no] power-over-ethernet redundancy
Usage: [NO] power redundancy [n+1|full]
Description: Set how much power is held in reserve for redundancy.
NO
- All available power can be allocated to powered devices.
n+1
- One of the highest power supplies will be held in
reserve. In the event of a simgle power supply failure,
no powered devices will be shut down.
full - Half of the available power supplies will be held in
reserve.
Default: No PoE redundancy enforced.
Next Available Option:
■
< n+1 | full > -- Set how much power is held in reserve for redundancy
(NUMBER)
redundancy_type
■
power-over-ethernet redundancy
< n+1 | full >
Usage: [NO] power redundancy [n+1|full]
Description: Set how much power is held in reserve for redundancy.
NO
- All available power can be allocated to powered devices.
n+1
- One of the highest power supplies will be held in
reserve. In the event of a simgle power supply failure,
no powered devices will be shut down.
full - Half of the available power supplies will be held in
reserve.
Supported Values:
■
n+1
404
©
2009 Hewlett-Packard Development Company, L.P.
power-over-ethernet
Command Line Interface Reference Guide
Содержание 6200YL
Страница 2: ......
Страница 16: ...Introduction 14 2009 Hewlett Packard Development Company L P ...
Страница 22: ...Commands 20 2009 Hewlett Packard Development Company L P ...
Страница 505: ...503 2009 Hewlett Packard Development Company L P services Command Line Interface Reference Guide ...
Страница 676: ... cs3 cs4 cs5 cs6 cs7 674 2009 Hewlett Packard Development Company L P svlan Command Line Interface Reference Guide ...
Страница 764: ......