XON/XOFF
■
None
inactivity-timer
■
console inactivity-timer
< 0 | 1 | 5 | ... >
Usage: console inactivity-timer <0|1|5|10|15|20|30|60|120>
Description: Set the number of minutes of no activity detected on the
Console port before the switch terminates a communication
session. '0' means disable inactivity timer.
Default is 0.
Supported Values:
■
0
■
1
■
5
■
10
■
15
■
20
■
30
■
60
■
120
local-terminal
■
console local-terminal
< VT100 | NONE | ANSI >
Usage: console local-terminal <vt100|ansi|none>
Description: Set type of terminal being used for the current
console or telnet session (default is vt100).
Takes effect immediately. Not saved in configuration.
Terminal type options are:
vt100 = use VT100 terminal escape sequences.
ansi = use ANSI terminal escape sequences.
none = use a raw mode with no terminal escape sequences. Useful
for scripting.
See also 'console terminal help'.
Supported Values:
■
VT100 -- VT-100 terminal compatible.
■
NONE -- Raw mode with terminal escape sequences removed.
■
ANSI -- ANSI terminal compatible.
screen-refresh
■
console screen-refresh
< 1 | 3 | 5 | ... >
Usage: console screen-refresh <1|3|5|10|20|30|45|60>
Description: Set default number of seconds before screen is refreshed
on the repeat command. See 'repeat help' for details on
the 'repeat' command.
Supported Values:
■
1
94
©
2009 Hewlett-Packard Development Company, L.P.
console
Command Line Interface Reference Guide
Содержание 6200YL
Страница 2: ......
Страница 16: ...Introduction 14 2009 Hewlett Packard Development Company L P ...
Страница 22: ...Commands 20 2009 Hewlett Packard Development Company L P ...
Страница 505: ...503 2009 Hewlett Packard Development Company L P services Command Line Interface Reference Guide ...
Страница 676: ... cs3 cs4 cs5 cs6 cs7 674 2009 Hewlett Packard Development Company L P svlan Command Line Interface Reference Guide ...
Страница 764: ......