* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000
ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000
ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude
maximum for storage corresponds to a pressure minimum of 70 KPa.
Power Specification
12V @ 9.17A (110 W)
Product Specifications
Software
Security Features
HTTPS (HTTP exchanged over an SSL-encrypted session) is required for access
to the Virtual Connect Manager. Access to the Virtual Connect Manager is via
the system Onboard Administrator. Each user account can be configured for a
combination of four access privileges to control and/or view elements in the
Virtual Connect Manager. User verification by account name and password
(Case Sensitive).
Each user account can be configured for a combination of four access
privileges to control and/or view elements in the Virtual Connect Manager.
Role based customization to assign various privileges to Server Admin,
Network Admin and Storage Admin.
LDAP Authentication services provide role based security via an LDAP SSL
Directory Server connection.
authentication, authorization and accounting
RADIUS authentication and authorization
Administrator controlled password length and strength requirements.
Private VLAN's for secure connectivity between servers within a domain.
Compliant with United States Department of Defense Policy on Use of
Department of Defense (DoD) Information Systems Standard Consent Banner
and User Agreement.
Configurable filtering of multicast traffic
GUI and CLI session timeout
Trunking, Failover and
Other Networking
Features
Shared Uplink Sets using Link Aggregation Control Protocol (LACP) allows the
creation of Ethernet channeling with upstream switches that conform to IEEE
802.3ad. Ports can alternatively be configured for failover only.
External ports within a Port Set can be on the same VC Ethernet module or on
multiple VC modules within the VC domain.
In the event of an uplink failure to a data center switch, the next highest
performance uplink connection or aggregation will become active.
Fast MAC Cache failover enables rapid recovery of network connections when
a standby module becomes active.
QuickSpecs
HP Virtual Connect FlexFabric 10Gb/24-Port Module
Technical Specifications
DA - 13652 Worldwide — Version 20 — November 5, 2013