background image

HP 5500 EI Switch Series
accessories

Modules

 

HP 5500 2-port 10GbE XFP Module

JD359B

HP 5500 2-port 10GbE Local Connect Module

JD360B

HP 5500 1-port 10GbE XFP Module

JD361B

HP 5500/4800 2-port GbE SFP Module

JD367A

HP 5500/5120 2-port 10GbE SFP+ Module

JD368B

NEW

 HP 5500/5120 2-port 10GBASE-T Module

JG535A

Transceivers

 

HP X125 1G SFP LC LH40 1310nm Transceiver

JD061A

HP X120 1G SFP LC LH40 1550nm Transceiver

JD062A

HP X125 1G SFP LC LH70 Transceiver

JD063B

HP X110 100M SFP LC LH40 Transceiver

JD090A

HP X110 100M SFP LC LH80 Transceiver

JD091A

HP X130 SFP+ LC SR Transceiver

JD092B

HP X130 SFP+ LC LRM Transceiver

JD093B

HP X130 SFP+ LC LR Transceiver

JD094B

HP X120 1G SFP LC BX 10-U Transceiver

JD098B

HP X120 1G SFP LC BX 10-D Transceiver

JD099B

HP X110 100M SFP LC FX Transceiver

JD102B

HP X130 10G XFP LC LR Transceiver

JD108B

HP X130 10G XFP LC SR Transceiver

JD117B

HP X120 1G SFP LC SX Transceiver

JD118B

HP X120 1G SFP LC LX Transceiver

JD119B

HP X110 100M SFP LC LX Transceiver

JD120B

HP X135 10G XFP LC ER Transceiver

JD121A

HP X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable

JD095C

HP X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable

JD096C

HP X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable

JD097C

HP X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable

JG081C

HP X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable

JC784C

HP X120 1G SFP RJ45 T Transceiver

JD089B

HP X130 10G SFP+ LC ER 40km Transceiver

JG234A

Cables

 

HP X230 Local Connect 100 cm CX4 Cable

JD364B

HP X230 Local Connect CX4 300 cm Cable

JD365A

HP 0.5 m Multimode OM3 LC/LC Optical Cable

AJ833A

HP 1 m Multimode OM3 LC/LC Optical Cable

AJ834A

HP 2 m Multimode OM3 LC/LC Optical Cable

AJ835A

HP 5 m Multimode OM3 LC/LC Optical Cable

AJ836A

HP 15 m Multimode OM3 LC/LC Optical Cable

AJ837A

HP 30 m Multimode OM3 LC/LC Optical Cable

AJ838A

HP 50 m Multimode OM3 LC/LC Optical Cable

AJ839A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable

QK732A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable

QK733A

QuickSpecs

HP 5500 EI Switch Series

Accessories

DA - 13808   North America — Version 27 — January 16, 2014

Page  30

Содержание 5500-24G-SFP EI TAA

Страница 1: ...available with 24 or 48 Gigabit Ethernet ports Power over Ethernet PoE and non PoE models are available with optional GbE and 10 GbE expansion capability The all fiber model with dual power supplies is ideal for applications that require the highest availability Features and benefits Software defined networking OpenFlow supports OpenFlow 1 0 and 1 3 specifications to enable SDN by allowing separat...

Страница 2: ...rs a cable between two switches and shuts down the ports on both ends if the cable is broken preventing network problems such as loops IPv6 management provides future proof networking because the switch is capable of being managed whether the attached network is running IPv4 or IPv6 supports pingv6 tracertv6 Telnetv6 TFTPv6 DNSv6 syslogv6 FTPv6 SNMPv6 DHCPv6 and RADIUS for IPv6 Troubleshooting ing...

Страница 3: ... Layer 2 switching 32K MAC addresses provide access to many Layer 2 devices IEEE 802 1ad QinQ and Selective QinQ increase the scalability of an Ethernet network by providing a hierarchical structure connect multiple LANs on a high speed campus or metro network GARP VLAN Registration Protocol allows automatic learning and dynamic assignment of VLANs IEEE 802 1ad QinQ increases the scalability of an...

Страница 4: ...e downloads or unauthorized copying of a switch configuration file Guest VLAN provides a browser based environment to authenticated clients that is similar to IEEE 802 1X Endpoint Admission Defense EAD provides security policies to users accessing a network Port security allows access only to specified MAC addresses which can be learned or specified by the administrator Port isolation secures and ...

Страница 5: ...rts and use variable speed fans to improve energy efficiency Green initiative support provides support for RoHS and WEEE regulations Warranty and support Lifetime Warranty 2 0 advance hardware replacement for as long as you own the product with next business day delivery available in most countries Electronic and telephone support for Lifetime Warranty 2 0 limited 24x7 telephone support is availab...

Страница 6: ...ed Gigabit Ethernet SFP ports 8 dual personality ports autosensing 10 100 1000BASE T or SFPmin 0 max 32 SFP Transceivers min 0 max 32 SFP Transceivers 2 port expansion module slots 1 JD362A HP 5500 150WAC Power Supply Included 1U Height See Configuration Note 1 3 PDU CABLE NA MEX TW JP JD374A B2B C15 PDU Jumper Cord NA MEX TW JP PDU CABLE ROW JD374A B2C C15 PDU Jumper Cord ROW High Volt Switch to ...

Страница 7: ... CABLE ROW JD375A B2C C15 PDU Jumper Cord ROW High Volt Switch to Wall Power Cord JD375A B2E NEMA L6 20P Cord NA MEX JP TW HP 5500 48G PoE EI Switch w 2 Intf Slts JG240A 48 RJ 45 autosensing 10 100 1000 PoE ports 4 dual personality ports autosensing 10 100 1000Base T or SFP min 0 max 4 SFP Transceivers 2 port expansion module slots Power Supply included 1U Height See Configuration Note 1 3 PDU CAB...

Страница 8: ...the following options and results Switch Router Power Supply to PDU Power Cord B2B in North America Mexico Taiwan and Japan or B2C ROW Watson Default B2B or B2C for Rack Level CTO Switch Router Power Supply to Wall Power Cord Localized Option Watson Default for BTO and Box Level CTO High Volt Switch Router Power Supply to Wall Power Cord B2E Option Offered only in North America Mexico Taiwan and J...

Страница 9: ...E EI Switch w 2 Intf Slts CTO JG241A 24 RJ 45 autosensing 10 100 1000 PoE ports 4 dual personality ports autosensing10 100 1000Base T or SFP min 0 max 4 SFP Transceivers 2 port expansion module slots Power Supply included 1U Height See Configuration Note 1 3 6 7 PDU Cable NA MEX TW JP JG241A B2B C15 PDU Jumper Cord NA MEX TW JP PDU Cable ROW JG241A B2C C15 PDU Jumper Cord ROW High Volt Switch to W...

Страница 10: ...X JP TW Configuration Rules Note 1 The following Transceivers install into this Switch Use 0D1 if switch is CTO HP X120 1G SFP LC SX Transceiver JD118B HP X120 1G SFP LC LX Transceiver JD119B HP X120 1G SFP LC BX 10 U Transceiver JD098B HP X120 1G SFP LC BX 10 D Transceiver JD099B HP X124 1G SFP LC LH40 1310nm Transceiver JD061A HP X120 1G SFP LC LH40 1550nm Transceiver JD062A HP X125 1G SFP LC LH...

Страница 11: ...er Supply to Wall Power Cord B2E Option Offered only in North America Mexico Taiwan and Japan Rack Level Integration CTO Models Switch Chassis HP 5500 24G EI Switch JD377A 24 RJ 45 autosensing 10 100 1000 ports 4 dual personality ports autosensing 10 100 1000Base T or SFP min 0 max 4 SFP Transceivers 2 port expansion module slots Power Supply included 1U Height See Configuration Note 1 3 10 PDU CA...

Страница 12: ...100 1000Base T or SFP min 0 max 4 SFP Transceivers 2 port expansion module slots Power Supply included 1U Height See Configuration Note 1 3 10 PDU CABLE NA MEX TW JPC JD375A B2B 15 to C14 Jumper Cord NA PDU CABLE ROW JD375A B2C C15 PDU Jumper Cord ROW HP 5500 48G PoE EI Switch w 2 Intf Slts JG240A 48 RJ 45 autosensing 10 100 1000 PoE ports 4 dual personality ports autosensing10 100 1000Base T or S...

Страница 13: ...ired on orders without B2B B2C PDU Power Cord See Localization Menu REMARK When Switches Routers are Factory Racked Then B2B or B2C should be the Defaulted Power Cable option on the Switches Routers Note 10 If HP CTO Switch Chassis is selected for Rack Level Integration Then the Switch needs to integrate with 0D1 to the Rack Remarks Drop down under power supply should offer the following options a...

Страница 14: ...RK When Switches Routers are Factory Racked Then B2B or B2C should be the Defaulted Power Cable option on the Switches Routers Note 4 Not supported on JD377A JG241A JD375A JG240A JG251A JG250A JG252A JG253A Remarks If Power Supply is added to switch with power supply then Switch and Power Supply localization must match Drop down under power supply should offer the following options and results Swi...

Страница 15: ...orted only on the JD377A JG250A JD375A and JG251A Switches Note 5 Supported only on the JG241A JG252A JG240A and JG253A Switches Note 6 Each switch will only support 1 JD183A Power supply Options for the HPN 5500 Power Supplies HP X290 1000 A JD5 2m RPS Cable JD187A HP X290 1000 A JD5 Non PoE 2m RPS Cable JD188A HP X290 1000 B JD5 2m RPS Cable JD189A HP X290 500 800 1m RPS Cable JD190A HP X290 500...

Страница 16: ...nsceiver JD094B HP X240 10G SFP SFP 0 65m DAC Cable JD095C HP X240 10G SFP SFP 1 2m DAC Cable JD096C HP X240 10G SFP SFP 3m DAC Cable JD097C HP X240 10G SFP SFP 5m DAC Cable JG081C HP X240 10G SFP 7m DAC Cable JC784C Note 2 The following Transceivers install into this Module Use 0D1 if switch is CTO HP X135 10G XFP LC ER Transceiver JD121A HP X130 10G XFP SC LR Transceiver JD108B HP X130 10G XFP L...

Страница 17: ...r JD119B HP X125 1G SFP LC LH70 Transceiver JD063B HP X120 1G SFP LC LH40 1550nm XCVR JD062A HP X125 1G SFP LC LH40 1310nm XCVR JD061A HP X120 1G SFP LC BX 10 U Transceiver JD098B HP X120 1G SFP LC BX 10 D Transceiver JD099B HP X115 100M SFP LC FX Transceiver JD102B HP X110 100M SFP LC LX Transceiver JD120B HP X110 100M SFP LC LH40 Transceiver JD090A HP X110 100M SFP LC LH80 Transceiver JD091A HP ...

Страница 18: ...Cable AJ834A HP 2 m Multimode OM3 LC LC FC Cable AJ835A HP 5 m Multimode OM3 LC LC FC Cable AJ836A HP 15 m Multimode OM3 LC LC FC Cable AJ837A HP 30 m Multimode OM3 LC LC FC Cable AJ838A HP 50 m Multimode OM3 LC LC FC Cable AJ839A HP Premier Flex LC LC OM4 2f 1m Cbl QK732A HP Premier Flex LC LC OM4 2f 2m Cbl QK733A HP Premier Flex LC LC OM4 2f 5m Cbl QK734A HP Premier Flex LC LC OM4 2f 15m Cbl QK7...

Страница 19: ...rating Storage temperature 40ºF to 158ºF 40ºC to 70ºC Nonoperating Storage relative humidity 5 to 95 noncondensing Acoustic ISO 7779 Electrical characteristics Frequency 50 60 Hz Maximum heat dissipation 375 BTU hr 395 63 kJ hr Voltage 100 240 VAC Maximum power rating 110 W Notes Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning ...

Страница 20: ...dware HR578E 1 year 24x7 software phone support software updates HR577E 1 year 24x7 software phone support software updates Next Business Day Hardware Exchange HS658E 1 year 24x7 software phone support software updates 4 hour hardware exchange HS659E 3 year 24x7 software phone support software updates Next Business Day Hardware Exchange HS660E 3 year 24x7 software phone support software updates 4 ...

Страница 21: ... modules populated Safety UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN CSA C22 2 No 60950 1 EN 60950 1 A11 FDA 21 CFR Subchapter J ROHS Compliance Emissions FCC part 15 Class A VCCI Class A EN 55022 Class A CISPR 22 Class A ICES 003 Class A ANSI C63 4 2003 ETSI EN 300 386 V1 3 3 AS NZS CISPR22 Class A EN 61000 3 2 EN 61000 3 3 EN ...

Страница 22: ...re phone support software updates Next Business Day Hardware Exchange HS678E 4 year 24x7 software phone support software updates 4 hour Hardware Exchange HS679E 5 year 24x7 software phone support software updates Next Business Day Hardware Exchange HS680E 5 year 24x7 software phone support software updates 4 hour Hardware Exchange HS681E Refer to the HP website at www hp com networking services fo...

Страница 23: ...nter command line interface Web browser SNMP Manager IEEE 802 3 Ethernet MIB Notes 1 power supply included Services 3 year 4 hour onsite 13x5 coverage for hardware UV870E 3 year 4 hour onsite 24x7 coverage for hardware UV873E 3 year 4 hour onsite 24x7 coverage for hardware 24x7 software phone support UV876E 3 year 24x7 SW phone support software updates UV879E 1 year post warranty 4 hour onsite 13x...

Страница 24: ...rface Slots JG240A Ports 48 RJ 45 autosensing 10 100 1000 PoE ports IEEE 802 3 Type 10BASE T IEEE 802 3u Type 100BASE TX IEEE 802 3ab Type 1000BASE T IEEE 802 3at PoE Media Type Auto MDIX Duplex 10BASE T 100BASE TX half or full 1000BASE T full only 4 dual personality ports auto sensing 10 100 1000Base T or SFP 2 port expansion module slots 1 RJ 45 serial console port Supports a maximum of 48 autos...

Страница 25: ...r SNMP Manager IEEE 802 3 Ethernet MIB Services 3 year 4 hour onsite 13x5 coverage for hardware HQ080E 3 year 4 hour onsite 24x7 coverage for hardware HQ081E 3 year 4 hour onsite 24x7 coverage for hardware 24x7 software phone support HQ084E 3 year 24x7 SW phone support software updates HQ083E 4 year 4 hour onsite 13x5 coverage for hardware HQ085E 4 year 4 hour onsite 24x7 coverage for hardware HQ0...

Страница 26: ...imum power rating 575 W PoE power 370 W Notes Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules populated PoE power is the power supplied by the internal power supply It is dependent on the type and quantity of power supplies and...

Страница 27: ...ons Device management RFC 1157 SNMPv1 v2c RFC 1256 ICMP Router Discovery Protocol IRDP RFC 1305 NTPv3 RFC 1901 Community based SNMPv2 RFC 2452 MIB for TCP6 RFC 2454 MIB for UDP6 RFC 2573 SNMPv3 Applications RFC 2576 Coexistence between SNMP V1 V2 V3 RFC 2819 RMON RFC 3410 Management Framework RFC 3416 SNMP Protocol Operations v2 RFC 3417 SNMP Transport Mappings HTML and telnet management Multiple ...

Страница 28: ...odel VACM for the Simple Network Management MIBs RFC 1212 Concise MIB Definitions RFC 1213 MIB II RFC 1493 Bridge MIB RFC 1657 BGP 4 MIB RFC 1724 RIPv2 MIB RFC 1757 Remote Network Monitoring MIB RFC 1850 OSPFv2 MIB RFC 2012 SNMPv2 MIB for TCP RFC 2013 SNMPv2 MIB for UDP RFC 2233 Interface MIB RFC 2452 IPV6 TCP MIB RFC 2454 IPV6 UDP MIB RFC 2465 IPv6 MIB RFC 2466 ICMPv6 MIB RFC 2571 SNMP Framework ...

Страница 29: ...ing Architecture RFC 2375 IPv6 Multicast Address Assignments RFC 2460 IPv6 Specification RFC 2461 IPv6 Neighbor Discovery RFC 2462 IPv6 Stateless Address Auto configuration RFC 2463 ICMPv6 RFC 2574 SNMPv3 User based Security Model USM RFC 2575 SNMPv3 View based Access Control Model VACM RFC 2576 Coexistence between SNMP versions RFC 2578 SMIv2 RFC 2581 TCP6 RFC 2819 Four groups of RMON 1 statistic...

Страница 30: ... JD119B HP X110 100M SFP LC LX Transceiver JD120B HP X135 10G XFP LC ER Transceiver JD121A HP X240 10G SFP to SFP 0 65m Direct Attach Copper Cable JD095C HP X240 10G SFP to SFP 1 2m Direct Attach Copper Cable JD096C HP X240 10G SFP to SFP 3m Direct Attach Copper Cable JD097C HP X240 10G SFP to SFP 5m Direct Attach Copper Cable JG081C HP X240 10G SFP SFP 7m Direct Attach Copper Cable JC784C HP X120...

Страница 31: ...0 150W AC Power Supply JD362A HP 5800 5500 150W DC Power Supply JD366A HP RPS 800 Redundant Power System JD183A HP RPS 1600 Redundant Power System JG136A HP RPS 1600 1600W AC Power Supply JG137A Power cords HP X290 1000 A JD5 2m RPS Cable JD187A HP X290 1000 A JD5 Non PoE 2m RPS Cable JD188A HP X290 1000 B JD5 2m RPS Cable JD189A HP X290 500 800 1m RPS Cable JD190A HP X290 500 U 1m RPS Cable JD185...

Страница 32: ...tions and product numbers For details about services and response times in your area please contact your local HP sales office HP X125 1G SFP LC LH40 1310nm Transceiver JD061A A small form factor pluggable SFP Gigabit LH40 transceiver that provides a full duplex Gigabit solution up to 40km on a single mode fiber Ports 1 LC 1000Base LH port no IEEE standard exists for 1550 nm optics Connectivity Co...

Страница 33: ...ur area please contact your local HP sales office HP X125 1G SFP LC LH70 Transceiver JD063B A small form factor pluggable SFP Gigabit LH70 transceiver that provides a full duplex Gigabit solution up to 70km on a single mode fiber Ports 1 LC 1000BASE LH port no IEEE standard exists for 1550 nm optics Connectivity Connector type LC Wavelength 1550 nm Physical characteristics Dimensions 2 17 d x 0 6 ...

Страница 34: ...se contact your local HP sales office HP X120 1G SFP LC BX 10 D Transceiver JD099B A small form factor pluggable SFP Gigabit LX BX10 D transceiver that provides a full duplex Gigabit solution up to 10km on a single mode cable Ports 1 LC 1000BASE BX10 port IEEE 802 3ah Type 1000BASE BX10 D Duplex full only Connectivity Connector type LC Physical characteristics Dimensions 2 17 d x 0 6 w x 0 46 h in...

Страница 35: ... contact your local HP sales office HP X120 1G SFP LC LX Transceiver JD119B A small form factor pluggable SFP Gigabig LX transceiver that provides a full duplex Gigabit solution up to 550m on MMF or 10Km on SMF Ports 1 SFP 1000BASE LX port IEEE 802 3z Type 1000BASE LX Connectivity Connector type LC Wavelength 1300 nm Physical characteristics Dimensions 2 17 d x 0 6 w x 0 46 h in 5 51 x 1 52 x 1 17...

Страница 36: ...ode fiber optic with effective modal bandwidth of 2000 MHz km as detailed in TIA 492AAAC for distances of up to 300 m Maximum distance 10Gbps Transfer Rate Ethernet 300m Notes Cable Specs Tight buffered duplex fiber optic multimode OM3 50 125 um fiber optic cable and Ethernet assembly with LC duplex connectors on one end and LC duplex connectors on other end Dimensions Core diameter 50 3 0um Cladd...

Страница 37: ...D sources 1500 500 MHz km 850 1300nm Optical Glass For Laser sources 2000 500 MHz km 850 1300nm VCSEL Laser sources Shall achieve 600 600 meters 850 1300nm for Gigabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Mat...

Страница 38: ...t Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LED s...

Страница 39: ... meters 850 1300nm for Gigabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss le...

Страница 40: ...it Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LED ...

Страница 41: ...it Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LED ...

Страница 42: ...it Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LED ...

Страница 43: ...lease contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 2m Cable QK733A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material Riser...

Страница 44: ...lease contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 15m Cable QK735A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material Rise...

Страница 45: ...lease contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 50m Cable QK737A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material Rise...

Страница 46: ...r is the actual power consumption of the device with no ports connected Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules populated With one RPS1600 Power Supply the PRS1600 Redundant Power System can provide 1600W power output W...

Страница 47: ...ports plugged in and all modules populated Services Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office To learn more visit www hp com networking Copyright 2010 2014 Hewlett Packard Development Company L P The information conta...

Отзывы: