The
Digital
Communications
Analysis
Menus
Measure
Eye
Menu
Data
is
acquired,
histograms
are
built,
absolute
maximum
and
minimum
voltage/power
levels
,
as
well
as
relative
maximum
(top)
and
minimum
(base)
voltage/power
levels
,
are
determined.
Crossing
points
of
the
eye
are
located,
the
threshold
levels
are
calculated,
and
then,
depending
on
the
specic
measurement(s)
activated,
the
requested
parametric
measurements
are
calculated
(See
\How
to
Make
W
aveform
Measurements"
in
Chapter
7).
Up
to
four
parametric
measurements
can
be
active
any
time
a
valid
database
exists
.
These
measurements
can
include
any
of
the
eye
measurements
described
in
this
section
or
those
described
in
Chapter
8.
Eye
measurements
are
performed
only
on
a
color
graded
database
.
When
one
of
the
seven
measurements
located
in
the
Measure
Eye
menu
is
selected,
the
color
graded
database
will
be
activated
automatically
if
it
has
not
already
been
enabled.
N
O
T
E
The
accurac
y
of
e
ye
measurements
depends
on
the
amount
of
data
in
the
color
graded
database
.
F
or
the
rst
few
seconds
after
pushing
Clear
Displa
y
,
the
amount
of
data
ma
y
be
insucient
to
obtain
statistically
signicant
results,
and
displa
yed
measurements
ma
y
show
large
variability
.
In
rmware
re
vision
A.02.00
and
abo
v
e
,
it
is
possible
to
set
a
threshold
in
the
Dene
Measure
menu
so
that
measurement
v
alues
are
not
displa
y
ed
until
the
y
are
stable
.
Refer
to
the
description
of
Measure
Complete
in
Chapter
10
for
more
information.
6-31
Содержание 54750A
Страница 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Страница 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Страница 7: ...X Ray Radiation Notice vii ...
Страница 8: ...Declaration of Conformity viii ...
Страница 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Страница 28: ......
Страница 43: ...1 The Instrument at a Glance ...
Страница 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Страница 60: ...TheInstrument ataGlance ...
Страница 61: ...2 General Purpose Keys ...
Страница 69: ...3 Speci cations and Characteristics ...
Страница 76: ...Speci cationsand Characteristics ...
Страница 77: ...4 Calibration Overview ...
Страница 84: ...CalibrationOverview ...
Страница 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Страница 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Страница 137: ...6 The Digital Communications Analysis Menus ...
Страница 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Страница 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Страница 191: ...7 Waveform Measurements ...
Страница 211: ...8 Making Automatic Measurements ...
Страница 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Страница 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Страница 253: ...10 General Purpose Oscilloscope Menus ...
Страница 317: ...11 The General Function Menus ...
Страница 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Страница 415: ...12 Messages ...
Страница 421: ...13 How the Instrument Works ...
Страница 453: ...Index ...