11
Purpose Command
Display the statistics on Ethernet OAM link error
events after an Ethernet OAM connection is
established.
display oam link-event
{
local
|
remote
} [
interface
interface-type interface-number
]
Clear statistics on Ethernet OAM packets and Ethernet
OAM link error events.
reset oam
[
interface
interface-type interface-number
]
Ethernet OAM configuration example
Network requirements
On the network shown in
, perform the following operations:
•
Enable Ethernet OAM on Device A and Device B to auto-detect link errors between the two devices
•
Determine the performance of the link between Device A and Device B by collecting statistics about
the error frames received by Device A
Figure 1
Network diagram
Configuration procedure
1.
Configure Device A:
# Configure GigabitEthernet 1/0/1 to operate in active Ethernet OAM mode, and enable
Ethernet OAM for it.
<DeviceA> system-view
[DeviceA] interface gigabitethernet 1/0/1
[DeviceA-GigabitEthernet1/0/1] oam mode active
[DeviceA-GigabitEthernet1/0/1] oam enable
# Set the errored frame event detection window to 20000 milliseconds, and set the errored frame
event triggering threshold to 10.
[DeviceA] oam errored-frame period 200
[DeviceA] oam errored-frame threshold 10
[DeviceA-GigabitEthernet1/0/1] quit
2.
Configure Device B:
# Configure GigabitEthernet 1/0/1 to operate in passive Ethernet OAM mode (the default), and
enable Ethernet OAM for it.
<DeviceB> system-view
[DeviceB] interface gigabitethernet 1/0/1
[DeviceB-GigabitEthernet1/0/1] oam mode passive
[DeviceB-GigabitEthernet1/0/1] oam enable
[DeviceB-GigabitEthernet1/0/1] quit
3.
Verify the configuration: