background image

3  Connecting to a Windows NT Server 3.51

Windows 95 SR2

Windows 95 SR2

Requirements

HP Vectra with Windows 95 SR2.

3COM Etherlink 3C509-B Ethernet card and drivers disk ver 5.0.

Vectra VL8 and VE7/VE8 Driver Name: W95EL5X9.INF  Size: 16KB  
Date: 6/11/97

Vectra VL7 Driver Name: Elnk.Vxd Size: 30.2KB Date: 7/18/96

Windows 95 media.

Microsoft Windows NT Server 3.51 machine that supports Net BEUI, TCP/
IP, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols.

Device Configuration

Boot PROM

Disabled

Transceiver Type 

Auto Select

Network Driver Optimization 

Windows or OS/2 Client

Maximum Modem Speed

9600 Bps

Plug and Play Compatibility

Disabled

Full Duplex

Disabled 

Procedure

1

With the HP Vectra turned off, install the 3COM Etherlink III 3C509-B 
adapter card into an ISA slot.

2

Connect network cable media to the 3COM 3C509B card.

3

Insert a DOS bootable diskette and power on the machine.

4

After booting, insert the 3COM drivers disk “Etherlink 3C509-B Ethernet 
Drivers Ver. 5.0.” and change to Drive A: , and  execute “3C5X9CFG.EXE.” 

5

Select “Configure NIC,” and verify the resource settings listed above 

Vectra VL8

Vectra VL7

Vectra VE7/VE8

I/O Base Address

210

210

300

Interrupt Request 

Level

10

10

10

Содержание 3C509B-TP

Страница 1: ...Etherlink IIIB ISA Network Interface Card 10BT 3C509B TP Installation Guide ...

Страница 2: ...mes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett Packard This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Hewlett Packard Company Microsoft Windows and MS DOS ...

Страница 3: ...BIOS transfer protocols Netware client for DOS and MS Windows Device Configuration Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Power on the machi...

Страница 4: ...3Com Fast Etherlink Etherlink III Bus Master2 b Under the heading Select the driver for your network board insert the 3Com 3C590 drivers disk and set the path to A NETWARE CLI ENT If you have an HP preloaded HDD set path to C Masters Lan Drv 3C509 NWCLIENT c Press Enter to continue the installation d When prompted insert the corresponding disks to complete file transfer and driver installation e W...

Страница 5: ...erify the following entries for the Installation Configuration Summary YES C NOVELL CLIENT32 C WINDOWS 16 bit LAN drivers 3Com Etherlink III Parallel Tasking Family 14 Press F10 to save and continue 15 When prompted insert the corresponding disks to complete file transfer and driver installation 16 When the install utility is finished press CRTL ALT DEL to restart the machine 17 After windows load...

Страница 6: ...1 Connecting to a Netware 3 12 Server Windows for Workgroups ...

Страница 7: ...evice Configuration Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Power on the machine and restart Windows 95 SR2 in MS DOS Mode 3 Insert the 3COM ...

Страница 8: ...have a Hewlett Packard pre loaded HDD set the path statement to C MASTERS LANDRV 3C509B 11 High light the adapter labeled 3Com Etherlink III ISA 3C509 3C509B in ISA Mode and press OK 12 At the Network dialogue box click on the Identification folder 13 Enter your Computer Name Workgroup and Computer Description If you do not have a Computer name Workgroup name and Computer description contact your ...

Страница 9: ...indows Device Configuration I O Base Address 300 Interrupt Request Level 10 Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Power on the machine and ...

Страница 10: ...oard insert the 3Com 3C590 drivers disk and set the path to A NETWARE CLIENT If you have an HP preloaded HDD set path to C Masters LanDrv 3C509 NWCLIENT d Press Enter to continue the installation e When prompted insert the corresponding disks to complete file transfer and driver installation f When the install utility is finished press CRTL ALT DEL to restart the machine g After Windows loads open...

Страница 11: ...es for the Installation Configuration Summary YES C NOVELL CLIENT32 C WINDOWS 16 bit LAN drivers 3Com Etherlink III Parallel Tasking Family 14 Press F10 to save and continue 15 When prompted insert the corresponding disks to complete file transfer and driver installation 16 When the install utility is finished press CRTL ALT DEL to restart the machine 17 After windows loads open the NETWORK folder...

Страница 12: ...2 Connecting to a Netware 4 11 Server Windows for Workgroups ...

Страница 13: ...ype Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Power on the machine and restart Windows 95 SR2 in MS DOS Mode 3 Insert the 3COM drivers diskette ver 5 0 downloaded from 3COM s webs...

Страница 14: ...ded HDD set the path statement to C MASTERS LANDRV 3C509B WIN95 11 High light the adapter labeled 3Com Etherlink III ISA 3C509 3C509B in ISA Mode and press OK 12 At the Network dialogue box click on the Identification folder 13 Enter your Computer Name Workgroup and Computer Description If you do not have a Computer name Workgroup name and Computer description contact your network administrator 14...

Страница 15: ...equest Level 10 Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network Cable Media to the 3COM 3C509B card 3 After booting to DOS insert the...

Страница 16: ...Masters LanDrv 3C509B WFW311 13 Select 3Com Etherlink III 3C5X9 in the Unlisted or Updated Network Adapter dialog box and click OK 14 Make sure that the 3Com Etherlink III 3C5X9 NDIS2 NDIS3 is selected in Network Drivers 15 Accept the applicable network protocols and then click on CLOSE 3Com EtherLink III 3C5X9 NDIS2 NDIS3 Microsoft NetBEUI IPX SPX Compatible Transport with NetBIOS If you do not h...

Страница 17: ...3 Connecting to a Windows NT Server 3 51 Windows for Workgroups Ver 3 11 ...

Страница 18: ...3 Connecting to a Windows NT Server 3 51 Windows for Workgroups Ver 3 11 ...

Страница 19: ...nsceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network cable media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and power on the machine 4 After booti...

Страница 20: ...ialog box click OK If you have an HP pre loaded HDD set the path statement to C MASTERS LANDRV 3C509B 15 Select the 3Com Etherlink III ISA 3C509 3C509B in ISA mode and click OK 16 Accept the default Network Protocols as seen below and click on OK If you do not have the required information contact your network administrator Client for NetWare Networks 3Com EtherLink III ISA 3C509 3C509b IPX SPX co...

Страница 21: ...3 Connecting to a Windows NT Server 3 51 Windows 95 SR2 an HP preloaded HDD set the path to C MASTERS WIN95 SYSTEM CABS 21 To complete the installation select Yes to restart your computer ...

Страница 22: ...3 Connecting to a Windows NT Server 3 51 Windows 95 SR2 ...

Страница 23: ...mization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network cable media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and power on the machine 4 After booting insert the 3COM Software 3C509 B Ethernet ...

Страница 24: ...rd Detection dialog box h From the Drop Down List scroll down and select Other Requires disk from manufacturer then click on Continue i Set the path to A in the Insert Disk dialog box and then insert the 3COM 3C509 drivers disk j Click OK at the Install Driver dialog box If you have an HP pre loaded HDD set path to C Masters LanDrv 3C509 k Select 3Com Etherlink III 3C509 ISA Adapter in the Select ...

Страница 25: ...orking on your computer 10 Insert the Windows NT Workstation CD 11 In Windows NT Setup enter the path to your NT files and click on Continue If you have an HP preloaded HDD set path to C I386 12 Click on Do Not Detect from the Network Adapter Card Detection dialog box and click on Continue in the second Network Adapter Card Detection dialog box 13 From the Drop Down List scroll down and select Oth...

Страница 26: ...and hit enter 22 At the TCP IP Configuration screen choose to use DHCP or enter your TCP information and click on OK If you do not have the required information contact your network administrator 23 At the Domain Workgroup Settings Dialog Box click on OK to accept the default Workgroup as your workgroup name If you do not have the required information contact your network administrator 24 To compl...

Страница 27: ... Configuration Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and pow...

Страница 28: ... 15 Select 3Com Etherlink III 3C509 ISA Adapter and click OK 16 With 3Com Etherlink III 3C509 ISA Adapter listed in the Network Adapters window click on Next 17 Accept the applicable network protocols and click on Next If you do not have the required information contact your network administrator 18 At the Network Services prompt accept default settings and click on Next 19 Finish the network card...

Страница 29: ... the network click on Next 26 Specify your Computer Name Workgroup or Domain and click on Next If you do not have the required information contact your network administrator 27 After Network has been installed on this computer click on Finish 28 To complete the installation select Yes to reboot your computer ...

Страница 30: ...3 Connecting to a Windows NT Server 3 51 Windows NT Workstation 4 0 ...

Страница 31: ...uest Level 10 Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network Cable Media to the 3COM 3C509B card 3 After booting to DOS insert the 3...

Страница 32: ...asters LanDrv 3C509B WFW311 13 Select 3Com Etherlink III 3C5X9 in the Unlisted or Updated Network Adapter dialog box and click OK 14 Make sure that the 3Com Etherlink III 3C5X9 NDIS2 NDIS3 is selected in Network Drivers 15 Accept the applicable network protocols and then click on CLOSE 3Com EtherLink III 3C5X9 NDIS2 NDIS3 Microsoft NetBEUI IPX SPX Compatible Transport with NetBIOS If you do not ha...

Страница 33: ...er Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network cable media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and power on the machine 4 After booting ins...

Страница 34: ...ment to C MASTERS LANDRV 3C509B 15 Selectthe 3ComEtherlinkIIIISA 3C509 3C509B inISAmode andclick OK 16 Accept the default Network Protocols as seen below and click on OK If you do not have the required information contact your network administrator Client for NetWare Networks 3Com EtherLink III ISA 3C509 3C509b IPX SPX compatible Protocol NetBEUI 17 In the configuration folder click on Add then cl...

Страница 35: ...4 Connecting to a Windows NT Server 4 0 Windows 95 SR2 C MASTERS WIN95 SYSTEM CABS 22 To complete the installation select Yes to restart your computer ...

Страница 36: ...4 Connecting to a Windows NT Server 4 0 Windows 95 SR2 ...

Страница 37: ...uto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Bps Plug and Play Compatibility Disabled Full Duple Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network cable media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and power on the machine 4 After booting insert the 3C...

Страница 38: ...e Insert Disk dialog box and then insert the 3COM 3C509 drivers disk 15 Click OK at the Install Driver dialog box If you have an HP preloaded HDD set path to C Masters LanDrv 3C509 16 Select 3Com Etherlink III 3C509 ISA Adapter in the Select OEM Option dialog box and click OK 17 Click on the OK button in the Bus Location dialog box 18 Choose the appropriate network protocols by clicking the check ...

Страница 39: ...p Settings Dialog Box click on OK to accept the default Workgroup as your workgroup name If you do not have the required information contact your network administrator 24 To complete the installation remove the floppy disk and click on Restart Computer button in the Windows NT Workstation Networking Setup dialog box ...

Страница 40: ...4 Connecting to a Windows NT Server 4 0 Windows NT Workstation Version 3 51 ...

Страница 41: ...onfiguration Boot PROM Disabled Transceiver Type Auto Select Network Driver Optimization Windows or OS 2 Client Maximum Modem Speed 9600 Baud Plug and Play Compatibility Disabled Full Duplex Disabled Procedure 1 With the HP Vectra turned off install the 3COM Etherlink III 3C509 B adapter card into an ISA slot 2 Connect network media to the 3COM 3C509B card 3 Insert a DOS bootable diskette and powe...

Страница 42: ... 15 Select 3Com Etherlink III 3C509 ISA Adapter and click OK 16 With 3Com Etherlink III 3C509 ISA Adapter listed in the Network Adapters window click on Next 17 Accept the applicable network protocols and click on Next If you do not have the required information contact your network administrator 18 At the Network Services prompt accept default settings and click on Next 19 Finish the network card...

Страница 43: ... the network click on Next 26 Specify your Computer Name Workgroup or Domain and click on Next If you do not have the required information contact your network administrator 27 After Network has been installed on this computer click on Finish 28 To complete the installation select Yes to reboot your computer ...

Страница 44: ...4 Connecting to a Windows NT Server 4 0 Windows NT Workstation 4 0 ...

Страница 45: ......

Страница 46: ...Version Number 3Com 3c509 Rev 1 ...

Отзывы: