2-10
Chapter 2
HP 9000/K100 Memory Upgrade Installation
Installation Procedure (HP 9000/K100)
NOTE
Do not "rocker" the SIMM into the connector! Apply force evenly.
After All SIMMs Are Installed
After all SIMMs have been inserted, check them to ensure that they are seated evenly and that all
SIMMS are the same height (an incorrectly seated SIMM may stick out above the others). Also verify
that all SIMM pairs are configured correctly according to the SIMM rules described previously in this
guide. You will probably need to use a small flashlight to visually check the SIMMs.
Reattach the Memory Bulkhead
The memory cover plate has to be replaced before normal system operation resumes. The cover plate is
required for system cooling and RFI/EMI noise suppression. Once the cover plate is in place, proceed to
the power on and verification procedures in Chapter 3.