manualshive.com logo in svg
background image

HP StorageWorks 1000 Modular Smart Array
maintenance and service guide

This guide provides procedures and diagnostics needed for the maintenance, service, and troubleshooting of the HP

StorageWorks 1000 Modular Smart Array (MSA1000 or MSA).

Part number: 257547–003

Third edition: October 2006

Содержание 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive

Страница 1: ...aintenance and service guide This guide provides procedures and diagnostics needed for the maintenance service and troubleshooting of the HP StorageWorks 1000 Modular Smart Array MSA1000 or MSA Part number 257547 003 Third edition October 2006 ...

Страница 2: ...ensed to the U S Government under vendor s standard commercial license The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editoria...

Страница 3: ...22 Hard drive LEDs 23 SCSI hard drive LEDs 23 Fibre Channel I O module LEDs 25 Power supply fan assembly LEDs 26 SCSI I O module LEDs 27 4 Available diagnostic tools 29 Array Configuration Utility ACU overview 29 Array Configuration Utility Command Line Interface ACU CLI overview 30 MSA Command Line Interface MSA CLI overview 30 Array Diagnostics Utility ADU overview 30 HP Systems Insight Manager ...

Страница 4: ...you begin 73 Verifying component failure 73 Removing the component 73 Installing the component 74 Verifying proper operation 75 Replacing the controller controller cache or controller battery 76 Before you begin 83 Verifying component failure 77 Removing the controller 77 Removing the controller cache module 78 Removing the controller cache battery pack 78 Installing the controller cache battery p...

Страница 5: ...ing hard drive failure 99 Effects of hard drive failure 99 Compromised fault tolerance 100 Recovering from compromised fault tolerance enabling failed LUNs 100 Best practices when replacing hard drives 101 Automatic data recovery rebuild 102 Time required for a rebuild 102 Failure of another drive during rebuild 103 10 Array controller firmware 105 Determining the currently installed firmware vers...

Страница 6: ...otice 113 BSMI notice 113 Japanese notice 113 Korean notices 114 Safety notices 114 Battery replacement notice 114 Taiwan battery recycling notice 115 Power cords 115 Japanese power cord notice 115 Electrostatic discharge 115 Preventing electrostatic damage 115 Grounding methods 115 Index 117 6 ...

Страница 7: ...Tables 1 Document conventions 10 2 LCD panel messages 35 3 Component hot pluggability 67 maintenance and service guide 7 ...

Страница 8: ...8 ...

Страница 9: ...d audience This guide is intended for use by system administrators and technicians who are experienced with the following SAN management Network administration Network installation Prerequisites Before servicing the MSA make sure that you consider the following Knowledge of operating system Knowledge of related hardware software Previous version of the product and or firmware version Related docum...

Страница 10: ...ebsite addresses Bold text Keys that are pressed Text typed into a GUI element such as a box GUI elements that are clicked or selected such as menu and list items buttons tabs and check boxes Italic text Text emphasis Monospace text File and directory names System output Code Commands their arguments and argument values Monospace italic text Code variables Command variables Monospace bold text Emp...

Страница 11: ...plished by CSR For more information about CSR contact your local service provider For North America see the CSR website http www hp com go selfrepair Subscription service HP recommends that you register your product at the Subscriber s Choice for Business website http www hp com go e updates After registering you will receive e mail notification of product enhancements new driver versions firmware...

Страница 12: ...12 About this guide ...

Страница 13: ...218231 B22 Optional 4 Power button module 229201 001 n a Optional 5 Power supply module 212398 001 n a Optional 6 Blower fan module 123482 001 n a Optional 7 SCSI I O module with integrated EMU 229205 001 n a Optional 8 Fibre Channel I O module 229206 001 218960 B21 Optional Shipped items not illustrated AC power cords Contact HP Support Contact your HP Authorized Reseller Mandatory VHDCI SCSI cab...

Страница 14: ...s Contact HP Support Contact your HP Authorized Reseller Mandatory Faulty component return kit 249670 001 n a Mandatory Mandatory Parts for which customer self repair is mandatory These parts are designed for customer self repair If you request HP to replace these parts you will be charged for the travel and labor costs of the service Optional Parts for which customer self repair is optional These...

Страница 15: ...s for the MSA1000 Included in this section Chassis specifications Memory specifications Power supply module specifications SCSI I O module specifications NOTE For information on the components and their part numbers see the Illustrated parts list maintenance and service guide 15 ...

Страница 16: ...er supply specifications Rated steady state power 377 watts Maximum peak power 681 watts Btus 2187 Btu hr Temperature range Operating 10 to 35 C derated 1 C per 1000 feet of elevation to 10000 ft 50 to 95 F Shipping 30 to 50 C 22 to 122 F Relative humidity noncondensing Operating 10 to 90 Non operating up to 95 Maximum wet bulb temperature Long term storage 29 C 84 2 F Short term storage 30 C 86 F...

Страница 17: ...tions Item Description Height 12 7 cm 4 5 in Width 15 9 cm 6 25 in Depth 24 1 cm 9 5 in Weight 2 9 kg 6 4 lb NOTE The MSA1000 System Unit power supply specifications are calculated without the fan SCSI I O module specifications Item Description Height 11 4 cm 4 5 in Width 3 5 cm 1 375 in Depth 24 1 cm 9 5 in Weight 0 6 kg 1 3 lb maintenance and service guide 17 ...

Страница 18: ...18 Specifications ...

Страница 19: ...nd module LEDs patterns Included sections Front view Rear view Chassis and component LEDs Front view 1 3 4 2 7 6 5 15577 1 Controller blank 2 RJ 45Z serial port to access the CLI 3 MSA1000 controller 4 Controller LCD display panel 5 Power on Standby button 6 Chassis status LEDs 7 Hard drives maintenance and service guide 19 ...

Страница 20: ...ibre Channel I O module Chassis and component LEDs The MSA chassis and its modular components are equipped with LEDs When the fault LED on any MSA component is amber promptly determine the reason for the alert by examining the component the messages displayed on the MSA controller LCD panel and system event logs such as those provided by HP Systems Insight Manager The following sections define the...

Страница 21: ...ate On Amber Fault detected in one or more subsystems 3 Fault Off Normal no faults detected NOTE System power does not shut off completely with the power button Standby removes power from most of the electronics and the hard drives but portions of the power supply and some internal circuitry remain active To remove the power completely disconnect all power cords from the device For instructions se...

Страница 22: ... activity On DMA transfers are active On This controller is active 7 Active Standby Off This controller is standby 8 Heartbeat Blinking The controller is functioning properly 9 Fault On amber An error message has been sent to the controller LCD display panel 10 Redundancy active On green The two controllers and the two Fibre Channel I O modules are in a redundant mode of operation On The controlle...

Страница 23: ...he hard drive is spinning up during POST Do not remove the hard drive Removing a hard drive at this time could terminate the current operation and cause data loss Blinking Blinking Blinking The hard drive is being accessed in one of the following ways The hard drive is part of a configured array that is being selected or updated by the ACU or MSA CLI The hard drive is being upgraded The hard drive...

Страница 24: ...replace the hard drive Off On or Blinking On Off The hard drive is online and configured as part of an array If necessary and if all other hard drives in the same array are online and working it is safe to replace the hard drive one of the following is happening If the Activity LED is Off the drive is configured and online but not currently active If the Activity LED is On or blinking the drive is...

Страница 25: ...r or there is no c ontroller present Solid Green A 1 Gb link is established and the status is good 2 1 Gb link status Blinking Amber A 1 Gb link was established but is now inactive Solid Green A 2 Gb link is established and the status is good 3 2 Gb link status Blinking Amber A 2 Gb link was established but is now inactive NOTE If both link status lights are Off a link has not been established sin...

Страница 26: ...e The rate at which air moves the airflow determines the amount of cooling This airflow is a function of fan speed rpm These fans under the control of the Environmental Monitoring Unit EMU or the associated power supply can operate at multiple speeds This ensures that when the enclosure temperature changes the fans can automatically adjust the airflow If one fan operates too slowly or completely s...

Страница 27: ...re and table describe their locations and meanings 3 1 2 15586 Item Name Condition Color Meaning Solid Green Power on 1 Power status Off Power off fault Blinking Green Activity 2 SCSI activity port A Off Off Blinking Green Activity 3 SCSI activity port B Off Off maintenance and service guide 27 ...

Страница 28: ...28 System components and LEDs ...

Страница 29: ...on Wizards Provides different operating modes enabling faster configuration or greater control over the configuration options Suggests the optimum configuration for unconfigured systems Displays on screen tips for individual steps of a configuration procedure Allows the setting of access privileges to specific storage LUNs to be limited to specific hosts Supports online array capacity expansion lo...

Страница 30: ... method of system management instead of a graphical user interface All supported operating systems can access the CLI Sample tasks include configuring the storage units LUNs limiting access to the storage and viewing controller and storage setup and status information Array Diagnostics Utility ADU overview The HP Array Diagnostic Utility ADU is a web based application that creates a report on all ...

Страница 31: ...hrough the SAN to the devices that are to be managed For more information about SMIS go to the HP SMIS website http h18006 www1 hp com storage smis html For more information about DMTF SNIA listings of HP SMIS providers see the SNIA website http www snia org ctp smi_conform System Event Analyzer SEA overview System Event Analyzer is a host based fault analysis utility included with the Web Based S...

Страница 32: ...s Automatic notification customer or HP Support Center Rule based allowing more frequent updates Proactive indictment with the operating system Web and command line interfaces For more information go to the WEBES website http h18023 www1 hp com support svctools webes jumpid reg_R1002_USEN 32 Available diagnostic tools ...

Страница 33: ... combined with runtime event notification messages to create a new set of controller display messages The display module is capable of holding up to 100 messages After this maximum size is reached older messages are removed to make room for newer ones When a new message is sent to the LCD the display shows that message and ignores any previous scrolling position This new message is now the most re...

Страница 34: ... Error messages Error messages indicate that a problem has occurred and may require user action to correct it The array controller Fault LED to the left of the LCD display panel lights whenever a new error message is sent to the display panel and has not been viewed and when an error message is currently displayed for viewing After all error messages have been viewed the LED turns off and is re li...

Страница 35: ...er input An issue has been found with a configured volume that may result in data loss so the volume has been disabled The exact nature of the issue is detailed in a previous LCD display message Yes the volume is enabled regardless of the issue The volume attempts to return to its normal operating state and the data is accessible No not selecting any option within the time out period the volume re...

Страница 36: ...d a firmware version mismatch with the two controllers and wants to copy the firmware from the other controller onto this controller Firmware on both controllers must match Scroll through and read the messages on both controller LCD panels to confirm the currently installed firmware versions on the controller Then respond appropriately to the prompt No do not clone Yes proceed with the cloning no ...

Страница 37: ...NG SYSTEM Informational An online firmware update is forcing an automatic restart of the system 17 ONLINE UPGRADE COMPLETE Informational An online firmware update has completed successfully 18 ONLINE UPGRADE INCOMPLETE Error An online firmware update was successful but a subsequent step failed In dual controller configurations this may cause the other to not update properly Restart the system In d...

Страница 38: ...ll cables are connected in a supported manner 4 Apply power to the external storage enclosures 5 Apply power to the MSA Should the issue persist contact HP support 30 I2C READ FAILURE I2C device name Error The MSA has a number of internal devices that are accessed via an I2C hardware bus One of these devices failed when attempting to read from it Certain I2C devices are considered critical and wil...

Страница 39: ...This controller is in standby and cannot access configured volumes on the MSA This controller can be made active if the current active controller fails assuming all redundant components are installed I O module cables and multipathing software 43 REDUNDANCY FAILED HARDWARE FAILURE Error While either attempting to enter redundant mode or already operating in redundant mode one of the two installed ...

Страница 40: ... enter redundant mode A process called firmware cloning which attempts to make them both the same firmware level has failed Manually update the firmware on the older array controller For instructions see the MSA firmware updating guide 46 REDUNDANCY HALTED EXPAND ACTIVE Informational If volume expansion is in progress then redundancy is not supported Volume expansion is initiated and tracked using...

Страница 41: ... either attempting to enter redundant mode or already operating in redundant mode one of the array controllers failed to allocate required memory Redundancy is disabled at this time If the MSA is currently involved in host I O remove the standby array controller wait 10 seconds and then reinsert it ensuring that it is fully seated in the chassis If this does not resolve the issue wait until downti...

Страница 42: ... modules on the two controllers are not the same size All cache memory modules must be the same size for redundancy to operate Remove the array controller that has been halted replace the cache modules with the appropriately sized ones wait 10 seconds and then reinsert the array controller ensuring that it is fully seated in the chassis 55 MSA1000 ACTIVE CONTROLLER Informational In dual controller...

Страница 43: ...ational Valid host data was found in the battery backed cache memory at power up This data has been flushed to the hard drives 64 CACHE DATA LOST BATTERY DEAD Error The battery on the cache memory was no longer charged If there was data in the cache memory it is lost 65 CACHE HARDWARE ENABLED Informational The cache hardware had been temporarily disabled but is now enabled again This may have been...

Страница 44: ...y at power up This data has been deleted This typically happens if cache modules are moved between array controllers 69 CACHE BATTERIES LOW RECHARGING Informational The batteries on the cache module are low and are being recharged 70 CACHE DISABLED NO CONFIGURATION Informational The cache has not been configured and is disabled The cache is configured using the Array Configuration Utility ACU or M...

Страница 45: ...iginal array controller power on the system without allowing any host I O and wait for cache data to be written to hard drives The system can be powered off and the cache module moved to the new location no The array controller will halt yes Cache data will be erased and operation of the array controller will continue 73 CACHE HARDWARE BATTERIES MISSING Error The cache module does not have its req...

Страница 46: ...ed as soon as possible 85 BAD DRIVE FRMWARE BOX n BAY n Error A SCSI hard drive has been detected that has known bad firmware on it Continued use of this hard drive could result in hard drive failure decreased performance or data loss Either the hard drive firmware should be updated or the hard drive should be replaced as soon as possible 86 DRIVE POSITION CHANGE DETECTED Informational The SCSI ha...

Страница 47: ...data loss The failed hard drives should be replaced as soon as possible If necessary restore data from backup 102 VOLUME n STATE INTERIM RECOVERY Informational The array controller has failed one or more SCSI hard drives that the configured volume is composed of but no data loss has occurred because fault tolerance is allowing the data to be recovered The failed hard drives should be replaced as s...

Страница 48: ...nd reinsert all SCSI hard drives ensuring they are fully seated in their bays Check the cables connecting the MSA to any attached storage enclosures Power on the attached enclosures and then the MSA 109 VOLUME n STATE WRONG DRIVE REPLACED Error The configured volume appears to have had known good SCSI hard drives replaced instead of known failed hard drives The MSA should be powered off and the go...

Страница 49: ... CLI 115 VOLUME n MEDIA EXCHANGED Informational All failed hard drives of the specified volume have been replaced by good hard drives or all unplugged hard drives in the volume have been plugged back in This message should be followed by message 02 ENABLE VOLUME n NO YES See the entry for 02 ENABLE VOLUME n NO YES 120 CONFIGURED VOLUMES n Informational The specified number of configured volumes wa...

Страница 50: ...ded 125 ACCESS CONTROL CONFLICT DETECTED Error A set of volumes has been migrated from one array controller to a different array controller that already has configured volumes on it The migrated volumes have access controls defined for them that conflict with the existing configuration The access controls have been modified so as to allow the migration to proceed Run the Array Configuration Utilit...

Страница 51: ...ure sensor on the array controller indicates that the array controller has exceeded the safe operating range The MSA should be powered off as soon as possible to avoid hardware failure Check all MSA fans and ensure they are operating Any failed fan should be replaced Ensure that there is a module or blanking panel cover plate in all MSA chassis bays and slots Empty bays affect the airflow and cool...

Страница 52: ... are in the power up sequence then the most recent version of firmware will be used If one array controller has already completed the power up sequence and is active then its version of firmware will be used even if less recent 304 ROM CLONING DONE Informational In dual controller MSA only this indicates that the two array controllers in an MSA have finished copying one array controller s version ...

Страница 53: ...firmware flash process It is now safe to turn off power to the system 311 EMU FLASH FAILED Error The EMU has failed the firmware flash process Attempt the flash process again Should the issue persist contact HP support 312 FIRMWARE FLASH STARTED ON BOX n Informational A firmware flash operation has started on an attached storage enclosure 313 FIRMWARE FLASH DONE ON BOX n Informational A firmware f...

Страница 54: ...ty of the MSA 407 STORAGE BOX n OVERHEATED Error The temperature in the specified storage enclosure has exceeded the safe operating range The MSA should be powered off as soon as possible and immediately after that the enclosure should be powered off to avoid hardware failure Check all MSA fans and ensure they are operating Any failed fan should be replaced Ensure that there is a module or blankin...

Страница 55: ...abled incorrectly Verify that the external storage enclosures are connected properly to the MSA For more information see the MSA installation guide 500 INITIALIZING PCI SUBSYSTEM Informational The array controller s PCI subsystem is being initialized as part of the power up sequence 501 PCI SUBSYSTEM HARDWARE FAILURE Error The array controller s PCI subsystem has encountered a critical error durin...

Страница 56: ... switch ensuring that it is fully seated in the chassis Should the issue persist contact HP support 515 FIBRE DEVICE HARDWARE FAILURE Error The array controller firmware does not recognize the device in the Fibre Channel I O bay The device has failed or is not supported by the installed firmware version If the device was not recently installed or the firmware was not recently downgraded remove the...

Страница 57: ...lable 520 UNKNOWN I O MODULE DETECTED Error The MSA cannot determine the type of I O module installed in the bay Do the following 1 Remove power from any external storage enclosures 2 Remove power from the MSA 3 Re seat all Fibre Channel and SCSI I O modules 4 Apply power to any external storage enclosures 5 Apply power to the MSA 6 Verify that the MSA has the latest version firmware installed Sho...

Страница 58: ...58 LCD panel and message descriptions ...

Страница 59: ...ling an interconnect blank Removing or installing a hard drive blank Replacing a hard drive Replacing the controller controller cache or controller battery Replacing a Fibre Channel I O module Replacing a 2 Gb small form factor pluggable SFP transceiver Replacing a power supply assembly Replacing a fan module Replacing the SCSI I O module Replacing the power button module Replacing the MSA1000 cha...

Страница 60: ...g the diagnosis period HP or HP service providers or partners identifies that the repair can be accomplished by the use of a CSR port HP will ship that part directly to you for replacement There are two categories of CSR parts Mandatory parts for which customer self repair is mandatory If you request HP to replace these parts you will be charged for the travel and labor costs of this service Optio...

Страница 61: ...characters define the revision level The replacement component revision level must be the same as or later than the number on the failed component The greater the revision level the later the revision Returning the defective component In the materials shipped with a CSR component HP specifies whether the defective component must be returned to HP In cases where it is required you must ship the def...

Страница 62: ...ng Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Make sure that you are properly grounded when touching a static sensitive component or assembly Place hard drives with the Printed Circuit Board PCB side down Use conductive field service tools Grounding methods There are several methods for grounding Use one or more of the follow...

Страница 63: ... network interface connection To reduce the risk of electrical shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle WARNING Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component Contact with this surface could result in injury WARNING Power supplies or systems marked with ...

Страница 64: ...emoval Remove all pluggable power supplies and modules to reduce the weight of the product Load the heaviest item first and load the rack from the bottom up This makes the rack bottom heavy and helps prevent the rack from becoming unstable Extend the leveling jacks to the floor Rest the full weight of the rack on the leveling jacks Attach stabilizing feet to the rack if it is a single rack install...

Страница 65: ...emoving any access covers for non hot pluggable areas Do not replace non hot pluggable components while power is applied to the product Power off the device and then disconnect all AC power cords Do not exceed the level of repair specified in the procedures in the product documentation All troubleshooting and repair procedures are detailed to allow only subassembly or module level repair Because o...

Страница 66: ...is performing rebuilds RAID migrations array expansions LUN expansions or experiencing heavy I O avoid physical configuration changes such as adding or replacing hard drives or hot plugging a controller or any other component For example hot adding or replacing a controller while under heavy I O may cause a momentary pause performance decrease or lass of access to the MSA while the new controller ...

Страница 67: ...n the enclosure Table 3 Component hot pluggability Component Hot pluggable Non hot pluggable Redundant power supply fan assembly X MSA array controller dual controller configurations X Fibre Channel I O module dual controller configurations X SCSI I O module X MSA chassis X Power switch module X MSA array controller single controller configurations X Fibre Channel I O module single controller conf...

Страница 68: ... Particular attention should be paid to the plug electrical outlet and the point where the cord exits from the product After all hardware components are installed and the unit is in place the power can be connected WARNING To reduce the risk of electric shock or damage to the equipment Do not disable the power cord s grounding plug The grounding plug is an important safety feature Plug the power c...

Страница 69: ... button on the front of the MSA The LED on the Power Standby button changes from amber to solid green indicating that the MSA has been powered on 3 Wait up to four minutes for the MSA to complete its startup routine NOTE If you installed a redundant controller and Fibre Channel I O module in the MSA the CLONE FIRMWARE message might be displayed Press the button on the controller to copy the firmwa...

Страница 70: ...ect all the power cords to remove power completely from the system To remove power from the MSA do the following 1 Ensure that a known good backup is available 2 Schedule a maintenance window 3 From the servers in the network stop all access to the MSA 4 Press and hold down the MSA Power On Standby button for five seconds to place the MSA in Standby mode NOTE Placing the MSA in standby mode disabl...

Страница 71: ...cement component within one or two minutes If the internal temperature exceeds acceptable limits the device may overheat and automatically shut down or restart Parts can be damaged by electrostatic discharge Use proper anti static protection Removing an interconnect blank 1 Loosen the thumbscrew that holds the blank in place 1 2 Remove the blank from the back of the unit 2 2 1 15568 Installing an ...

Страница 72: ...hut down or restart Parts can be damaged by electrostatic discharge Use proper anti static protection Removing a hard drive blank CAUTION A blank or a hard drive must be installed in each hard drive slot Failure to install a blank or hard drive in all slots could result in thermal failures 1 Review all warnings cautions and preparation procedures as detailed in Warnings and precautions 2 Push in t...

Страница 73: ...a time two if using RAID 6 When you replace a hard drive the controller uses data from the other hard drives in the array to reconstruct data on the replacement hard drive If you remove more than one hard drive a complete data set is not available to reconstruct data on the replacement drive s and permanent data loss could occur Never remove a working hard drive The amber Drive Failure LED indicat...

Страница 74: ...before continuing to the next step Handling a hard drive while the internal media is spinning can damage the media 5 Pull the hard drive out of the enclosure bay 3 1 2 3 15591 Installing the component 1 Press the hard drive ejector button 1 and pull the release lever to the full open position 2 1 2 15592 2 Slide the replacement hard drive into the same bay from which the old hard drive was just re...

Страница 75: ...t configurations allow the replacement hard drive to be reconstructed automatically from parity data stored on the other hard drives While the data is being rebuilt the LEDs will flash Verifying proper operation The hard drive LEDs light one at a time and then turn off together to indicate that the system has recognized the new drive In fault tolerant configurations allow the replacement hard driv...

Страница 76: ...rt Parts can be damaged by electrostatic discharge Use proper anti static protection CAUTION When replacing a controller HP recommends that the old cache module be moved to the new controller In single controller configurations if the controller fails this ensures that disk writes that might have been trapped in the old controller s cache are completed In dual controller configurations if a contro...

Страница 77: ...w all controller specific warnings cautions and preparation procedures as detailed in Before you begin 3 In all single controller configurations power off the MSA as instructed in Removing power from the MSA 4 In operational dual controller configurations access an MSA management utility such as the MSA Command Line Interface MSA CLI or the Array Configuration Utility ACU and disable the controlle...

Страница 78: ... controller Using the same cache module completes disk writes trapped in the controller cache 1 Remove the controller from the chassis as instructed in Removing the controller 2 Locate the controller cover clips on the rear lower left and right sides of the module by holding the controller upright with the latch handle facing you 3 Unlatch the controller cover clips 1 on the rear of the controller...

Страница 79: ... hard drives This is particularly important for data that has been cached by a posted write operation but has not yet been written to the hard drives Batteries on a new controller might be discharged In this case a POST message is displayed on the controller display panel when the controller is powered on indicating that the controller cache module is temporarily disabled No user action is require...

Страница 80: ...ve the second battery pack on this cache module Installing the controller cache battery pack 1 Remove the array controller as instructed in Removing the controller 2 Remove the controller cache module as instructed in Removing the controller cache module 3 Remove the controller cache battery pack as instructed in Removing the controller cache battery pack 4 Hook the top of the new NiMH battery pac...

Страница 81: ...isabled while the batteries are charging and is automatically re enabled after the batteries are fully charged Installing the controller cache module 1 Slide the cache module into the controller 1 until the side latches are fully engaged 2 1 2 15515 2 Close the controller cover 3 Insert the serviced controller into the chassis as instructed in Installing the controller Installing the controller 1 ...

Страница 82: ...nto the other controller For information see Cloning controller firmware Verifying proper operation After replacing the array controller controller cache module or cache module battery pack verify that The controller Heartbeat LED is blinking The controller Fault LED is off No new error messages are displayed on the array controller LCD display panel After installing a new array controller verify ...

Страница 83: ... O may cause a momentary pause performance decrease or loss of access to the MSA while the new controller is starting up After the startup process is complete full functionality will be restored In dual controller configurations the MSA controller and Fibre Channel I O modules are hot pluggable and the MSA does not need to be powered down during the replacement However you must first use an MSA ma...

Страница 84: ...ings and precautions 2 Disconnect the cable from the Fibre Channel I O module 3 While grasping the module handle 1 slide the release latch to the right 2 4 Pull the module out of the chassis 3 2 3 1 15569 Installing the component 1 Slide the replacement Fibre Channel I O module into the MSA chassis bay until the module clicks into place 2 Either move the SFP transceiver from the old Fibre Channel ...

Страница 85: ...amaged by electrostatic discharge Use proper anti static protection Verifying component failure Before replacing the SFP Verify that the Fibre Channel I O module status LED is not illuminated or is blinking amber Check the array controller LCD display panel for error messages Removing the component 1 Review all warnings cautions and preparation procedures as detailed in Warnings and precautions 2 ...

Страница 86: ... fan You must remove the operational fan from the defective power supply and install the fan on the new power supply The fan blades rotate at a high speed and do not stop immediately when power is removed from the MSA Allow time for the blades to stop rotating Avoid touching the rotating blades when removing the fan The fan shell must be handled carefully to avoid breaking it Do not press on the c...

Страница 87: ...he power supply module latch 1 and slide the assembly into the chassis until it is fully seated 2 1 2 15558 2 Connect the AC power cord to the power supply 3 Engage the cord lock Verifying proper operation After replacing the power supply verify that The power supply LED is solid green No new error messages are displayed on the array controller LCD panel maintenance and service guide 87 ...

Страница 88: ... new power supply The fan blades rotate at a high speed and do not stop immediately when power is removed from the MSA Allow time for the blades to stop rotating Avoid touching the rotating blades when removing the fan The fan shell must be handled carefully to avoid breaking it Do not press on the center section of the fan shell circular panel covering the blades To avoid damaging the fan blades ...

Страница 89: ... the new fan with the power supply connector 1 3 3 2 1 15556 2 Slide the replacement fan into the fan base 2 until the tabs snap into place 3 Verifying proper operation After replacing the fan module verify that The fan starts operating immediately The fan LED is On No new error messages are displayed on the array controller LCD panel maintenance and service guide 89 ...

Страница 90: ...e may overheat and automatically shut down or restart Parts can be damaged by electrostatic discharge Use proper anti static protection Verifying component failure Before replacing the SCSI I O module Verify that the module status LED is not illuminated or is flashing amber Check the array controller LCD display panel for error messages and take appropriate action Removing the component 1 Review a...

Страница 91: ... pluggable Before replacing the module all I O from the servers must be stopped and the MSA must be powered down Before you begin CAUTION Before removing a component or blanking panel from an operational device make sure that you have the replacement part available Removing a component or blank impacts the airflow and cooling ability of the device To avoid possible overheating insert the new or re...

Страница 92: ...nt is complete 3 Disconnect the power cables from the MSA 4 Disconnect the Fibre Channel cables from the MSA 5 Disconnect the SCSI cables from the MSA 6 Remove the hard drives in slots 10 through 14 making sure to carefully label each hard drive as it is removed CAUTION To prevent data loss each hard drive must be installed in the same slot from which it was removed 7 Remove the MSA from the rack ...

Страница 93: ...e array controller LCD panel Replacing the MSA1000 chassis In the event of a backplane board failure a new chassis must be ordered All original component parts of the MSA can be reinstalled in their respective locations on the new backplane The parts that will be removed from the old chassis and then reinstalled in the new chassis include Controllers or controller blank Hard drives or blanks Power...

Страница 94: ...94 Customer replaceable components ...

Страница 95: ...specific administration utility to add LUNs 7 If necessary for your operating system reboot the server to use the new storage Migrating existing storage enclosures Even though extensive design and testing has been performed HP recommends backing up data before migrating the enclosure to the MSA Perform the administrative steps to defragment file systems or volumes prior to performing the backup Th...

Страница 96: ...e MSA CLI Before moving hard drives the following conditions must be met No hard drives are failed missing or degraded No more than 32 LUNs will be configured for a controller The array should be in its original configuration with no active spare hard drives Capacity expansion is not running Controller firmware is the latest version recommended Before moving an array from one controller to another...

Страница 97: ...ata NOTE When extending a LUN under Windows 2000 upgrade the LUN to Dynamic before creating a partition on that LUN If the LUN already has a partition when it is upgraded to Dynamic Windows may not allow LUN extension See the Windows 2000 documentation for details about Dynamic and Basic LUNs NOTE Windows may allow only four partitions on each LUN Additional space created may not be accessible if ...

Страница 98: ...98 Capacity expansion and extension ...

Страница 99: ... the various LED combinations see Hard drive LEDs Other ways to determine that a hard drive has failed include the following LEDs on the storage system chassis illuminate amber if failed hard drives are inside However this LED also illuminates when other problems occur such as when a fan fails a redundant power supply fails or the system overheats LEDs on the hard drives illuminate amber if a hard...

Страница 100: ...nected to the same power source and that power source it interrupted fault tolerance may be compromised Recovering from compromised fault tolerance enabling faulted LUNs If fault tolerance is compromised inserting replacement hard drives does not improve the condition of the logical unit The procedure to re enable or accept a LUN that is unresponsive is performed in the Array Configuration Utility...

Страница 101: ...sufficient capacity In systems that use external storage enclosures be sure that the server is the first unit to be powered down and the last to be powered back up Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up When a hot pluggable hard drive is inserted all disk activity on the array is paused while the new hard drive is...

Страница 102: ...ther failed drives in a RAID 1 0 configuration Failure of a second drive in a RAID ADG configuration Time required for a rebuild The time required for a rebuild varies considerably depending on several factors The priority that the rebuild is given over normal I O operations you can change the priority setting through the Array Configuration Utility ACU or MSA Command Line Interface MSA CLI The am...

Страница 103: ...ine LED of the replacement drive stops blinking and the rebuild abnormally terminates If this situation occurs restart the server and the storage system The system may temporarily become operational long enough to allow recovery of unsaved data In any case locate the faulty drive replace it and restore data from backup maintenance and service guide 103 ...

Страница 104: ...104 Hard drive failures and faulted LUNs ...

Страница 105: ...rate in a variety of operating system environments several updating methods are available To perform an update obtain the following items from the MSA website Controller firmware on the Software Firmware Drivers page Firmware updating guide on the Technical Documents page Cloning controller firmware NOTE Cloning is possible only in dual controller configurations Each time a system with two control...

Страница 106: ...nter redundant operation On a subsequent power cycle both controllers enter redundant mode Recovering corrupted firmware If the controller detects a firmware corruption the following message is displayed on the LCD panel ERROR ROM CORRUPT SEND IMG VIA XMODEM To recover the controller you must obtain a current firmware image and send it to the controller using a serial connection 1 Go to the MSA we...

Страница 107: ...er Send File b Click Browse and navigate to the location of the firmware image obtained in step 1 c Expand the Protocol drop down box and select 1K XModem d Click Send A status window is displayed 4 Wait for the transfer process to complete NOTE This process may take up to 15 minutes Do not interrupt this process 5 Wait for the controller to automatically restart maintenance and service guide 107 ...

Страница 108: ...rations only if the newly installed firmware on the recovered controller differs from the firmware on the active controller the CLONE FIRMWARE LCD message is displayed See Cloning controller firmware 108 Array controller firmware ...

Страница 109: ...andard CD ROM burning utility Do not simply copy the ISO file to a blank CD NOTE If the latest Firmware Maintenance CD does not include the latest release of hard drive firmware contained in a Smart Component the CD can be used in combination with the latest individual Smart Component package to perform the update 2 Insert the CD into the CD ROM hard drive of a ProLiant server with access to the M...

Страница 110: ...110 SCSI hard drive firmware ...

Страница 111: ...designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful int...

Страница 112: ...iance with FCC Rules and Regulations Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification your product has been assigned a unique Regulatory Model Number The RMN can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer ...

Страница 113: ...pean Norms in parentheses are the equivalent international standards and regulations EN55022 CISPR 22 Electromagnetic Interference EN55024 IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 IEC61000 4 8 IEC61000 4 11 Electromagnetic Immunity Power Quality EN61000 3 2 IEC61000 3 2 Power Line Harmonics EN60950 IEC60950 Product Safety EN61000 3 3 IEC61000 3 3 Power Line Flicker Also app...

Страница 114: ...a vanadium pentoxide or an alkaline battery pack There is risk of fire and burns if the battery pack is not properly handled To reduce the risk of personal injury Do not attempt to recharge the battery Do not expose to temperatures higher than 60 C Do not disassemble crush puncture short external contacts or dispose of in fire or water Replace only with the HP spare part designated for this produc...

Страница 115: ...t they will not be walked on and cannot be pinched by items placed upon or against them Pay particular attention to the plug electrical outlet and the point where the cords exit from the product Japanese power cord notice Electrostatic discharge To prevent damage to the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electric...

Страница 116: ...standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats Use conductive field service tools Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have an HP authorized reseller install the part NOTE For more information on static electricity or assista...

Страница 117: ... 77 failure 76 latches 77 81 removing 77 replacing 76 securing 81 controller display components 33 error messages 34 informational messages 34 message types 34 operating modes 33 user input messages 35 controller display messages access control conflict detected 50 access control resources exceeded 50 array controller disabled 51 array controller overheated 51 array controller overheating 51 array...

Страница 118: ...ed hardware failure 39 redundancy failed I O request error 41 redundancy failed mismatch firmware 40 redundancy failed mismatch hardware 40 redundancy failed no second controller 42 redundancy failed out of memory 41 redundancy failed PCI Bus error 42 redundancy halted expand active 40 redundancy halted firmware cloned 41 remove other controller now 42 replacement hard drive found box 45 restartin...

Страница 119: ...id config box 3 n bay n 47 invalid SCSI cabling 55 no cache module found 43 online upgrade flashing failed 37 online upgrade incomplete 37 PCI bridge ASIC self test failure 55 PCI subsystem hardware failure 55 pilot 2 contrlr not supported 36 recovery ROM autoflash failed 52 redundancy failed cache Dimms mismatch 42 redundancy failed cache size mismatch 40 redundancy failed firmware lockup 41 redu...

Страница 120: ... cache module MB 43 configured volumes 49 EMU flash done 53 EMU flash started 53 fibre subsystem link ok 56 firmware flash done 53 firmware flash done on box 53 firmware flash started 53 firmware flash started on box 53 firmware version 35 hard drive hot added box bay 46 hard drive hot removed box bay 46 hard drive position change detected 46 hard drive position charge invalid 46 initializing fibr...

Страница 121: ...ard drive operational 23 I O EMU 27 online 73 power supplies fan assemblies 26 SCSI I O module 27 lithium battery 114 loading rack warning 64 M Modular Smart Array 1000 illustrated parts breakdown and spare parts list 13 MSA controller replacing 76 updating the firmware 105 verifying failure 77 MSA1000 controller LEDs 22 N noise declaration German 114 non hot pluggable devices removing 70 non hot ...

Страница 122: ...on equipment 63 symbols in text 10 system preventing electrostatic discharge to 115 Systems Insight Manager description 30 T Taiwan EPA battery recycling and disposal 115 technical support HP 11 service locator website 11 telephone numbers FCC questions 112 text symbols 10 thermal failure caution 72 toe straps using 116 tools conductive type 116 required for servicing 61 type recommended 62 U upda...

Отзывы: