2-12
Troubleshooting
Table 2-11
Hard Drive Test Error Codes
Error Code
Description
Recommended Action
1701-xx
Hard drive format test failed.
1. Run Compaq Utilities and verify drive type.
1702-xx
Hard drive read test failed.
2. Verify that all secondary drives have
secondary drive capability.
1703-xx
Hard drive write/read/compare test failed.
3. Replace the hard drive and retest.
1704-xx
Hard drive random seek test failed.
4. Replace the system board and retest.
1705-xx
Hard drive controller test failed.
1706-xx
Hard drive ready test failed.
1707-xx
Hard drive recalibration test failed.
1708-xx
Hard drive format bad track test failed.
1709-xx
Hard drive reset controller test failed.
1710-xx
Hard drive park head test failed.
1715-xx
Hard drive head select test failed.
1716-xx
Hard drive conditional format test failed.
1717-xx
Hard drive ECC* test failed.
1719-xx
Hard drive power mode test failed.
1724-xx
Network preparation test failed.
1736-xx
Drive monitoring test failed.
*
ECC = Error Correction Code
Table 2-12
Video Test Error Codes
Error Code
Description
Recommended Action
501-xx
Video controller test failed.
The following actions apply to error codes 501-xx
through 516-xx:
502-xx
Video memory test failed.
1. Disconnect external monitor and test with
internal LCD display.
503-xx
Video attribute test failed.
2. Replace the display assembly and retest.
504-xx
Video character set test failed.
3. Replace the system board and retest.
505-xx
Video 80 × 25 mode 9 × 14 character
cell test failed.
506-xx
Video 80 × 25 mode 8 × 8 character
cell test failed.
507-xx
Video 40 × 25 mode test failed.
511-xx
Video screen memory page test failed.
512-xx
Video gray scale test failed.
514-xx
Video white screen test failed.
516-xx
Video noise pattern test failed.
2402-xx
Video memory test failed.
The following actions apply to error codes
2402-xx through 2456-xx:
2403-xx
Video attribute test failed.
1. Run Compaq Utilities.
2404-xx
Video character set test failed.
2. Disconnect external monitor and test with
internal LCD display.
2405-xx
Video 80 × 25 mode 9 × 14 character cell
test failed.
3. Replace the display assembly and retest.
4. Replace the system board and retest.
Continued
Содержание 140
Страница 56: ...3 2 Illustrated Parts Catalog 3 1 System Unit Figure 3 1 System Unit ...
Страница 58: ...3 4 Illustrated Parts Catalog 3 2 Mass Storage Devices Figure 3 2 Mass Storage Devices ...
Страница 61: ...Illustrated Parts Catalog 3 7 3 4 Standard and Optional Boards Figure 3 4 Standard and Optional Boards ...
Страница 64: ...3 10 Illustrated Parts Catalog 3 6 Miscellaneous Parts Figure 3 6 Miscellaneous Parts ...
Страница 132: ...A 6 Connectors Table A 9 Speaker Connector Pin Signal 1 Shield 2 Left channel audio 3 Right channel audio ...