background image

the general maintenance notes.
Depending on pond water conditions,
cleaning may be required more
frequently.

Once a year- Completely disassemble
the unit including the Rotor Assembly
as described in the general
maintenance notes, and wash all
components in clean, freshwater.
Replace worn or broken parts.

When not in use, the unit should be
removed, thoroughly washed and
cleaned, dried and stored in a dry frost
protected area. Always store the unit
with the foam and foam cover off to
ensure adequate ventilation and
drying.

(Refer to Fig 11).

Contact the Consumer Services Helpline
on +44 (0)121 313 1122

Item 
Numbers

1. Foam (single)

1408 

2. UV Lamp

1519

3. Quartz Tube Assembly

1526

4. Pump rotor

3418

5. Fountain and extension 

Z31785

segment bagged set

Under normal conditions, the
EasyClear™ will support up to 72cm of
fish. Introduce fish slowly over the first
few weeks, up to 20% of the maximum
recommended level, increasing to 50%
after six months. The balance will allow
for fish growth.

We guarantee you Clearwater or your
money back!

This guarantee runs for 12 months
after purchase, provided that:

• You have followed the installation
and operating instructions

• You are using equipment of the
correct size and stocking level for your
pond

• You consult our He44 (0)121
313 1122 early enough for any
problems to be put right

• The product has been returned
undamaged.  A refund can only be
authorised by Hozelock Cyprio and is
made at the place of purchase.

If this unit, excluding the Rotor
Assembly, Filter Foam & UV Lamp
becomes unserviceable within 3 years
of the date of purchase it will be
repaired or replaced at our option free
of charge, unless in our opinion it has
been damaged or misused. Liability is
not accepted for damage due to
accident, improper installation or use.

Liability is limited to replacement of a
faulty unit. This guarantee is not
transferable. It does not affect your
statutory rights. 

To obtain the benefits of the
guarantee, firstly contact Hozelock
Cyprio Consumer Services who may
request that the filter is sent along
with proof of purchase directly to the
address provided.

DAMAGE CAUSED BY RUNNING THE
EASYCLEAR OUT OF WATER OR BY
FROST INVALIDATES THE GUARANTEE.

3 Year Product

Guarantee

Spare Parts

Fish Stocking and

Density

Clearwater Guarantee

Winter Storage

Содержание EASYCLEAR 3000

Страница 1: ...2823 3003 EASYCLEAR 3000 Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 info hozelock com www hozelock com 33854 002 ...

Страница 2: ...1 4A 3 5 6 7 4B 8 2 P P O N L M Q R S J K G C E D B A I F H ...

Страница 3: ...V X Y V V Z Z W W 10 9 U T 10A ...

Страница 4: ...11 5 3 2 4 1 ...

Страница 5: ... the ball joint Fig 4A L DO NOT OPERATE THIS UNIT WITHOUT THE OUTER CAGE ATTACHED USING THE UNIT WITHOUT THE OUTER CAGE MAY INVALIDATE YOUR WARRANTY The clear tube inside the unit is made from quartz glass and care should be taken during installation and maintenance We recommend the use of eye protection and suitable gloves The EasyClear 3000 is fitted with a 5W UVC lamp Exposure to Ultra Violet U...

Страница 6: ...UPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED REPAIRED MAINTAINED OR HANDLED Do not use the supply cable to lift the unit as this may cause damage We recommend fitting a lifting cord to the hook feature on the base when the filter is installed in deep water Fig 1 H Check that the voltage marked on the unit corresponds to the mains supply A 10mA OR 30mA RESIDUAL C...

Страница 7: ...en using the EasyClear for a waterfall the entire unit should be submersed Connection Place the unit next to the pond and route the cable back to the mains supply Ensure that you allow for enough cable for positioning the product in the desired location in the pond Bell Fountain Fig 1 Locate the Bell Support B to the Bell Main Body C and push fully home Position the Bell D to the Body Assembly and...

Страница 8: ...casionally it will become necessary to clean or replace parts Refer to the safety sections before attempting any maintenance Fountain Head Fig 1 I Follow the below procedure if the fountain head is blocked 1 Place a coin or similar in the slot and gently lever off the fountain head 2 Rinse in clean water and reassemble Foam Follow the below procedure if flow appears reduced 1 Release the Foam Cove...

Страница 9: ...f the two o rings on the Quartz Tube Assembly Fig 11 3 If these are damaged in any way or you can not guarantee a water tight seal contact Hozelock Consumer Services Biological Filter Normally there is no need to remove the biomedia as any cleaning may kill the colonies of bacteria that make toxic waste harmless 1 Remove the foam 2 The bag of Kaldnes Biomedia Fig 7 P can be removed for cleaning 3 ...

Страница 10: ...uns for 12 months after purchase provided that You have followed the installation and operating instructions You are using equipment of the correct size and stocking level for your pond You consult our Helpline 44 0 121 313 1122 early enough for any problems to be put right The product has been returned undamaged A refund can only be authorised by Hozelock Cyprio and is made at the place of purcha...

Страница 11: ... white flap inside pump chamber moves freely e Ensure rotor is clean and moves freely POOR FOUNTAIN DISPLAY a As above b Clean the Fountain Head UV LAMP NOT WORKING a Check power supply is on b Check fuse RCD and wiring c Replace the lamp d The Overload Protection may have operated see Overload Protection section PUMP NOT WORKING a Check power supply is on b Check fuse RCD and wiring c Check the r...

Страница 12: ...Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 info hozelock com www hozelock com 33854 002 PLEASE NOTE Do not dispose of in household waste ...

Отзывы: