Hozelock Aquaforce 1000 Скачать руководство пользователя страница 3

responsible for their safety. Children should be
supervised to ensure that they do not play with the
appliance. (

Australia & NZ only

) This appliance is not

intended for use by young children or infirm persons
unless they have been adequately supervised by a
responsible person to ensure that they can use the
appliance safely. Young children should be supervised
to ensure that they do not play with the appliance.

3. 

WARNING

: Always unplug or disconnect all appliances

in the pond from the electricity supply before putting
your hands in the water whilst equipment is being
installed, repaired, maintained or handled.

4.  Never use the mains supply cable to lift the pump, as

this may cause damage. We recommend fitting a lifting
cord to the handle on the strainer cage when the pump
is installed in deep water.

5.  Do not operate or leave the pump in freezing

conditions.

6.  Protect the pump from direct sunlight. Direct sunlight

may overheat the motor.

7.  Never allow the pump to run dry.

8.  Do not operate this pump without the strainer cage

properly attached. Using the pump without the strainer
cage may invalidate your warranty.

9. 

ATTENTION

: This product is not suitable for water

temperatures above 35ºC.

10. 

ATTENTION

: Do not operate this product if the mains

supply cable or the motor has become damaged in any
way. The supply cable cannot be replaced as it is
permanently encased in the motor housing and should
therefore be disposed of according to local regulations.

11. If you live in a hard water area (water with high

calcium or limescale content), the pump, rotor assembly
and inside of motor should be cleaned at regular
intervals (See MAINTENANCE).

12. Only use accessories which have been designed for use

with this product. The use of any other accessories may
invalidate your guarantee.

UK ONLY:

Installing this product in the garden is classed as

'notifiable' in the revised Building Regulations for
England and Wales. The Regulations require you to tell
your local authority building control department that
you intend to install this product before installation.

Your local authority will let you know how you can get

your installation approved.

ELECTRICAL CONNECTIONS – UK VERSION

1. 

WARNING

: Always unplug or disconnect all appliances

in the pond from the electricity supply before putting
your hands in the water whilst equipment is being
installed, repaired, maintained or handled.

2.  Check that the voltage marked on the unit corresponds

to the mains supply.

3.  The pump is supplied with 10m of 3 core electric cable

which is permanently connected and sealed to the
motor.

The supply cable cannot be replaced. If the cable is
damaged, the pump should be discarded.

This product is designed to be permanently wired to the
mains supply in a dry weatherproof enclosure through a
Double-Pole Switched Fused Spur - (Disconnector) to BS
3676 – with a minimum contact gap of 3mm in each
pole. Fitted with a 3 or 5 Amp fuse. The installation
must conform to the National and Local wiring
regulations which could include the use of plastic or
metal conduit to protect the cable.

4.  A 10mA or 30mA Residual Current Device (RCD) Must

be fitted to the mains supply.

5. 

WARNING

: This appliance must be earthed and it is

essential that the connections are made using the
following code;

Brown – Live

Blue – Neutral

Green/Yellow – Earth

The BROWN lead should be connected to the LIVE
terminal which may be marked with an ‘L’ or coloured
brown or red.

The BLUE lead should be connected to the NEUTRAL
terminal which may be marked with an ‘N’ or coloured
blue or black.

The GREEN/YELLOW lead should be connected to the
EARTH terminal which may be marked with an ‘E’ ( ) or
coloured green or green/yellow.

6. If an extension cable is required, this should be

connected to the end of the pump cable using a
weatherproof cable connector.

The joint must be positioned in a suitable dry housing.
The extension cable should be of 3 core 0.75mm2
Polychloroprene rubber insulated cable (ref: HO5 RN-F)
and permanently wired to the mains supply with a 3 or
5 Amp fuse.

7.  The pump cable (and extension cable) should be

positioned and adequately protected against damage
especially where contact with gardening equipment,
(lawn mowers, forks etc..) children and domestic
animals may occur.

8.  Consult a qualified electrician or local authority if in any

doubt about wiring to the mains supply.

Содержание Aquaforce 1000

Страница 1: ...2823 1580 1581 1582 Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 info hozelock com www hozelock com 43385 001 aquaforce 1000 2500 4000 ...

Страница 2: ...g the impeller Remove the obstruction and wait for the pump to cool down Then switch on the pump again NOTE AQUAFORCE 2500 4000 YOU MUST SWITCH OFF THE MAINS SUPPLY BEFORE THE PUMP WILL RESET GENERAL SAFETY GUIDELINES Failure to observe the following notices may result in injury product damage or loss of fish 1 This pump has been designed for the use with ponds only Only use this pump for the oper...

Страница 3: ...Your local authority will let you know how you can get your installation approved ELECTRICAL CONNECTIONS UK VERSION 1 WARNING Always unplug or disconnect all appliances in the pond from the electricity supply before putting your hands in the water whilst equipment is being installed repaired maintained or handled 2 Check that the voltage marked on the unit corresponds to the mains supply 3 The pum...

Страница 4: ...onto its mounting area ensuring that the outlet adaptor rests in the recess in the lower part of the cage Fig 5 Note 1000 model The pump locates into a cradle that is fixed to the lower cage Fig 1 g 7 Locate the mains supply cable into the recess on the side of the cage Ensure it is seated in the correct position so that the cable does not get trapped when the cage is closed Fig 6 8 Close the cage...

Страница 5: ...when being used as a filtration pump its solids handling capability will be maximised For best results the pump should not be placed directly on the bottom of the pond We recommend that the pump be installed on a flat level platform which is raised approximately 300mm above the bottom of pond This will ensure that sufficient water remains in the pond in the event of accidental leakage of pond wate...

Страница 6: ...pump chamber squarely away from the motor body d e Pull the rotor assembly c out of the motor body d Important Take extra care so as to not drop any of the small components See Fig 15 a for assembly of the 1000 rotor Fig 15 b for the assembly of the 2500 rotor and Fig 15 c for assembly of the 4000 rotor f Wash out all of the components in clean water Do not use detergents or other chemical cleaner...

Страница 7: ...0 3 Threaded Outlet Adaptor 1682 1682 1682 4 Ball Joint Z10013 Z10013 Z10013 5 Stepped Hosetail Nut Z10012 Z10012 Z10012 HOZELOCK CYPRIO 3 YEAR GUARANTEE To activate your warranty please go to http register hozelock com If this pump excluding the rotor assembly becomes unserviceable within 3 years of the date of purchase it will be repaired or replaced at our option free of charge unless in our op...

Страница 8: ...being In the EU when replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposal at least free of charge Performance Aquaforce 1000 2500 4000 6000 8000 12000 15000 Saleable Part number 1580 1581 1582 1583 1584 1585 1586 Volts V 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz Power W 25 30 50 65 95 130 180 Max Flow QMax...

Отзывы: