background image

4.1  Connect the filter’s supply cord (See section 1 – 

Safety & Electrical Connections). This switches 

on the UVC lamp. You can check that the lamp is 

working in dark conditions by switching off the 

pump briefly and looking for the blue glow from 

the end of the yellow venturi outlet (Fig. 7 (x)) .

4.2  Switch on the pump.
4.3  Periods of Operation: Keep the filter working 24 

hours a day. Ideally it should run all year round 

but at least throughout the feeding season 

(ie until water temperature falls below 10ºC). 

In winter, operating the pump and filter will 

maintain a basic level of useful bacteria in the 

E and will help prevent the pond icing 

over in all but the severest weather conditions. 

 

If the pump is switched off for winter, the filter 

media (foam and/or plastic biomedia) must be 

thoroughly washed before resuming filtration 

in the spring, and your E will need to 

be re-matured from scratch (see ‘Maturation’). 

Never feed your fish when the filter is not in use.

Maturation

5.1  Biological maturation means that the filter 

has built up enough nitrifying bacteria to 

convert harmful fish and other organic waste 

(ie ammonia, nitrite) into relatively harmless 

nitrate. The process normally takes 6-8 weeks, 

but depends on many factors such as water 

temperature, feeding rate and stocking density. 

Speed up maturation by adding a maturing 

agent such as Hozelock Cyprio Filter Start.

Cleaning

6.1  E filters deliver maximum performance 

with minimum maintenance.

 

However, as the foam blocks up less water can 

flow through the foam and cleaning becomes 

necessary. If the pond is very dirty, the filter 

may need cleaning every few days at first, as 

it takes up waste matter very quickly. Once the 

pond becomes clearer, there will be less waste 

to remove and the filter will need cleaning less 

often.

 

WARNING: Prolonged running of the filter 

when it needs cleaning will result in difficulty in 

cleaning and may reduce the life of the foam.

 

Switch off and isolate (by removing the fuse) the 

pump supplying water to the filter when it needs 

cleaning and the power supply to the E 

unit.

6.2  Switch off the supply pump at the mains.
6.3  Switch off E at the mains.
6.4  Gently remove the lid from the vessel (Fig 3).
6.5  Remove the foam(s) (Fig 11) and rinse it in the 

water left in the vessel. Do not over clean. Drain 

the vessel of all the waste and water.

6.6  Reposition the clean foam sheet onto the ends 

of the foam spacer ensure that the foam is 

positioned with the venturi passing through it 

and with the dimples in the foam facing away 

from the lid.

6.7  Switch the supply to the E on and 

check that the UVC lamp is working.

6.8  Gently locate the lid onto the vessel and snap 

down around the rim. Looking through the 

viewing hatch, ensure that the foam sheet is 

positioned below the outlet(s) in the vessel (Fig 

12).

6.9  Restart the pump, checking for leaks, which if 

left undetected could result in the pond being 

drained of water.

6.10  The biomedia is contained within a mesh 

bag. Normally, there is no need to remove the 

biomedia as any cleaning may kill the colonies 

of bacteria that make toxic waste harmless. 

However if the biomedia becomes heavily 

clogged, then remove the mesh bag containing 

the biomedia and rinse it is a bucket clean pond 

water and then replace it into the vessel. Never 

use tap water to clean the biomedia.

Maintenance

Maintenance of the electrical housing should only 

be carried out by a suitably qualified person or at a 

Service Centre.
Refer to the section “Safety & Electrical 

Connections” before attempting any maintenance.
Warning: Read these maintenance instructions 

before opening the appliance.
7.1  Replacing the UV lamp.
 

Warning: The appliance must be disconnected 

from the power supply before disconnecting 

the UV-C emitter.

 

A UV lamp’s effectiveness reduces significantly 

over time so you should replace your lamp every 

12 months even if the lamp is still functioning.

 

Remember: The product is fitted with an 

interlock that will turn the lamp off when the top 

cover is removed, so you can only see if the lamp 

is working in dark conditions, switching off the 

pump briefly and  looking for a bluish glow from 

bottom of the Venturi (Fig 7 (x)). 

 

Warning: Do not attempt to operate the UV-C 

emitter when the top cover is removed from 

the product’s lid.

 

Warning: The appliance must be disconnected 

from the supply before replacing the UV-C 

emitter.

Содержание Ecopower 10000

Страница 1: ...Ecopower 4000 6000 10000 www hozelock com 1866 1862 1864 1862 1864 1866 Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 www hozelock com 33910 000 2 YEAR GUARANTEE ...

Страница 2: ...1a 1b 3 1866 2 a b c 1862 1864 1862 x1 1864 x2 1866 x2 1 c f d h g 1862 x1 1864 x1 1866 x2 e ...

Страница 3: ...4 5 6 7 25mm 32mm 40mm 8 9 x 10 ...

Страница 4: ...11 12 13 14 15 16 17 y z STOP ...

Страница 5: ...nsory or mental capabilities Maintenance of the electrical housing should only be carried out by a suitably qualified person or at a Service Centre Warning Safety Electrical Connections 1 1 WARNING ALWAYS UNPLUG OR DISCONNECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED REPAIRED MAINTAINED OR HANDLED 1 2 This filt...

Страница 6: ... Pond location determines the daily amount of sunlight or shade a pond receives Ponds exposed to full sunshine throughout the day have a Condition Factor of 25 Climate Climate affects water temperatures and fish activity rate feeding requirements The more active the fish the greater the demands on the filtration system In hot climates ie South Africa the Condition Factor is 35 In temperate climate...

Страница 7: ...rmly back filled with compacted sand to support the unit Always ensure that the filter outlet s are at least 100mm above the level of the water in your pond 3 3 Connection Place the unit next to the pond and route the cable back to the mains supply Ensure that you allow for enough cable for positioning the product in the desired location in the pond 3 4 For transportation the drain outlet has been...

Страница 8: ... 6 2 Switch off the supply pump at the mains 6 3 Switch off Ecopower at the mains 6 4 Gently remove the lid from the vessel Fig 3 6 5 Remove the foam s Fig 11 and rinse it in the water left in the vessel Do not over clean Drain the vessel of all the waste and water 6 6 Reposition the clean foam sheet onto the ends of the foam spacer ensure that the foam is positioned with the venturi passing throu...

Страница 9: ...ibed above in 7 1 7 2 12 Refit the top cover viewing hatch and replace the four screws The lamp will not work unless the top cover is screwed down 7 2 13 Restart the supply pump checking for leaks 7 2 14 Switch the supply to the Ecopower on Winter Storage When not in use the unit should be removed thoroughly washed and cleaned dried and stored in a dry frost protected area Always store the unit wi...

Страница 10: ...educed flow through filter Foams are blocked Clean filter See Cleaning Supply hose blocked Check supply hose and pond return hose for blockages Water does not clear New Filter has not matured yet The pond water clarity should start to improve within 2 3 weeks but full biological maturation can take 6 8 weeks before the filter is fully effective Wrong sized filter for your pond Check you are using ...

Страница 11: ......

Страница 12: ...your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being In the EU when replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposal at least...

Отзывы: