MI-500/MI-600/MI-700 

2. About Safety 

2.1 Important Safety Instructions 

The MI-500/MI-600/MI-700 Microinverter is designed and tested according to international safety 
requirements. However, certain safety precautions must be taken when installing and operating 
this  inverter.  The  installer  must  read  and  follow  all  instructions,  cautions  and  warnings  in  this 
installation manual. 

  

All operations including transport, installation, start-up and maintenance, must be carried out by 

qualified, trained personnel. 

  

Before installation, check the unit to ensure free of any transport or handling damage, which could 

affect  insulation  integrity  or  safety  clearances.  Choose  installation  location  carefully  and  adhere  to 

specified  cooling  requirements.  Unauthorized  removal  of  necessary  protections,  improper  use, 

incorrect  installation  and  operation  may  lead  to  serious  safety  and  shock  hazards  or  equipment 

damage.

  

Before  connecting  the  Microinverter  to  the  power  distribution  grid,  contact  the  local  power 

distribution grid company to get appropriate approvals. This connection must be made only by qualified 

technical personnel. It is the responsibility of the installer to provide external disconnect switches and 

Over current Protection Devices (OCPD).

  

Only  one  photo  voltaic  module  can  be  connected  to  one  input  of  the  inverter.  Do  not  connect 

batteries  or  other  sources  of  power  supply.  The  inverter  can  be  used  only  if  all  the  technical 

characteristics are observed and applied.

  

Do  not  install  the  equipment  in  adverse  environment  conditions  such  as  flammable,  explosive, 

corrosive, extreme high or low temperature, and humid. Do not use the equipment when the safety 

devices do not work or disabled.

  

Use personal protective equipment, including gloves and eye protection during the installation.

  

Inform the manufacturer about non-standard installation conditions.

  

Do not use the equipment if any operating anomalies are found. Avoid temporary repairs.

  

All  repairs  should  be  carried  out  using  only  qualified  spare  parts,  which  must  be  installed  in 

accordance  with  their  intended  use  and  by  a  licensed  contractor  or  authorized  Hoymiles  service 

representative.

  

Liabilities arising from commercial components are delegated to their respective manufacturers.

  

Anytime the inverter has been disconnected from the public network, please be extremely caution 

as some components can retain charge sufficient to create a shock hazard. Prior to touching any part 

of the inverter please ensure surfaces and equipment are under touch safe temperatures and voltage 

potentials before proceeding.

  

Hoymiles accepts No liability for damage from incorrect or improper operation

  

Electrical Installation & Maintenance shall be conducted by licensed electrician and shall  comply 

with Local Wiring Rules

 

Содержание MI-500

Страница 1: ...Version B1 0 2019...

Страница 2: ...control the production of a single photovoltaic module directly consequently improving the flexibility and reliability of the system About the manual This manual contains important instructions for t...

Страница 3: ...Introduction 8 3 4 Dimension 9 4 About Function 9 4 1 Work Mode 9 5 About Installation 10 5 1 Accessories 10 5 2 Installation Precaution 11 5 3 Space Distance Required 11 5 4 Preparation 12 5 5 Instal...

Страница 4: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 4 MI 500 MI 600 MI 700 9 2 AC Output 21 9 3 Efficiency Safety and Protection 22 9 4 General Data 22...

Страница 5: ...nstall and maintain this Microinverter under the guide of this document for safety purpose 1 3Symbols Used The safety symbols in this user manual are show as below Symbol Usage Indicates a hazardous s...

Страница 6: ...photo voltaic module can be connected to one input of the inverter Do not connect batteries or other sources of power supply The inverter can be used only if all the technical characteristics are obse...

Страница 7: ...in operation Danger of high voltages Danger to life due to high voltage in the microinverter Beware of hot surface The inverter can become hot during operation Avoid contact with metal surfaces durin...

Страница 8: ...700W Adapted to 60 72 cells PV panels Peak efficiency 96 70 CEC weighted efficiency 96 50 Static MPPT efficiency 99 80 Dynamic MPPT efficiency 99 76 in overcast weather High reliability NEMA6 IP67 en...

Страница 9: ...feed in to Public Grid Zero Export Control Under this mode Microinverter s generation is limit base on the current house loads there will be no extra power feed in to the Public Grid Stand by There a...

Страница 10: ...nal please contact our sales to purchase base on the quantity required on actual installation Object Description A AC Extension Cable B AC End Cable Female 2m 12 AWG cable C AC Female Connector D AC M...

Страница 11: ...ons under the PV module to avoiding direct sunlight rain exposure snow layup UV etc Note For some countries the DTU will be required to meet the local grid regulation e g G98 99 for UK 5 3 Space Dista...

Страница 12: ...ng due to an increase in the microinverter internal temperature do not expose it to direct sunlight To avoid overheating always make sure the air flow around the inverter is not blocked Do not install...

Страница 13: ...bserve the certification documents concerning the maximum number of Micro inverters permitted for installation at each cable section The Microinverter must be under the module out of long term exposur...

Страница 14: ...icroinverter s AC Male connector B Connect the other side of the AC End Cable to the distribution box and wire it to the local grid network Close the distribution box after the wiring is completed Not...

Страница 15: ...e PV modules above the microinverters B Connect the PV modules DC cables to the DC input side of the microinverter The recommended installation need to keep the Microinverter underneath the photovolta...

Страница 16: ...lease contact your installer to check the AC wiring 04 Please Contact your installer and provide Panel specs 05 Please contact your installer to check the DC side installation and PV configuration 06...

Страница 17: ...the in appendix Technical Data of this microinverter 2 Check the connection to the utility grid Verify utility power is present at the inverter in question by removing AC then DC power Never disconnec...

Страница 18: ...e fault removed Conduct an annual inspection on various components and clean the equipment with a vacuum cleaner or special brushes Do not attempt to dismantle the Microinverter or make any internal r...

Страница 19: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 19 MI 500 MI 600 MI 700 7 Sample Wiring Diagram Fig 2 Single Phase Wiring Diagram Fig 3 Three phase wiring diagram...

Страница 20: ...quent handling easier Transportation of the equipment especially by road must be carried out by suitable ways for protecting the components in particular the electronic components from violent shocks...

Страница 21: ...mum input voltage V 60 60 60 Maximum input current A 10 5 11 5 11 5 Model MI 500 MI 600 MI 700 Rated output power W 500 600 700 Rated output current A 2 17 230V a c 2 08 240V a c 2 40 208V a c 2 27 22...

Страница 22: ...y 96 50 96 50 96 50 Nominal MPPT efficiency 99 80 99 80 99 80 Night time power consumption mW 50 50 50 Model MI 500 MI 600 MI 700 Ambient temperature range 40 65 40 65 40 65 Operating temperature rang...

Страница 23: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 23 MI 500 MI 600 MI 700 Appendix 1 Installation Map...

Отзывы: