![Hoymiles HY3 Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hoymiles/hy3-series/hy3-series_user-manual_2171465022.webp)
6. Electrical Connection
20
MANUAL-HY3-EN-V1.00
User Manual
6.7
Smart Meter Connection
The inverter needs the data from the smart meter, to monitor the power usage in the house, and
control the generation/charge/discharge process according to smart meter
’
s data.
The smart meter communication only works when it is compatible with the inverter. Please use the
provided meter from the accessory box.
Procedure
Step 1
Install the smart meter.
Normally, the smart meter
should be placed in or near
the grid distribution box right
after the billing meter, in order
to account all the loads.
Grid
Energy Meter
Common Loads
N
A
C
B
k
Wh
Smart Meter
B
M
S
2
B
M
S
1
C
A
N
1
C
A
N
2
M
E
T
E
R
D
R
M
ON
OFF
PV1
PV2
A1+
A1-
B1+
B1-
B2+
B2-
BAT1+
BAT1-
BAT2+
BAT2 -
WIFI
GRID
EPS
Step 2
Connect the communication
cable between inverter and
smart meter.
The smart meter port
’
s PIN
definition is shown in the
below.
1 - NULL
2 - G ND
3 - NULL
4 - NULL
5 - NULL
6 - G ND
7 - 485A
8 - 485B
A B C
N
A B
C
N
1
4 7
10
10
3 6 9
485A 485B
From Grid
To Inverter
and Loads
NOTICE