5.5 Installation Steps
Step 1. Fix Microinverter on the Rail
A) Mark the approximate center of each panel on the frame.
B) Fix the screw on the rail.
A) Hang the microinverter on the screw (shown as picture below), and tighten the screw.The silver
cover side of the Microinverter should be facing the panel.
*Note: Please install the microinverter at least 50cm above the ground/roof for better communication with Hoymiles
DTU.
Step 2. Complete the AC Connection
A) Attach the AC bus cable with the mounting rail, and fix the cable with tie wraps.
B) Push the AC connector of the microinverter to the trunk cable connector until you hear “click”.
C)
If there is any vacant bus port, please plug the AC sub cap on the vacant plug to ensure
waterproof and dustproof.
*Note: Under the circumstances that need to remove the inverter AC cable from bus port, please use the AC connector
unlock tool and insert the tool into the side of AC port.