© 2019 Hoymiles Converter Technology Co., Ltd. All rights reserved. 9
HM-300NT/HM-350NT/HM-400NT
4. About Function
4.1 Work Mode
Normal
: Under this mode, Microinverter is operating normally and convert DC power into AC power to
support the house loads and feed in to Public Grid.
Zero Export Control
: Under this mode Microinverter’s generation is limit base on the current house
loads, there will be no extra power feed in to the Public Grid.
Stand by
: There are several circumstance that Microinverter will stay in Standby mode:
- The current condition is contradicted with Microinverter operating requirement.
- No house loads or the Export control value has been set as “0” on the DTU under the Zero Export
Control mode.
5. About Installation
5.1 Accessories
Item
Description
A
AC Bus Cable, 12/10 AWG Cable
B
M8*25 screws
C
DC Extension Cable, 1m
D
AC Connector Unlock Tool
E
Bus Connector Unlock Tool
F
AC Sub Cap
G
AC Bus End Cap, IP67
Содержание HM-300NT
Страница 1: ...Version 1 2 June 2020...