HM-300NT/HM-350NT/HM-400NT
Step 2. Complete the AC Connection
A) Attach the AC bus cable with the mounting rail, and fix the cable with tie wraps.
B) Push the AC connector of the microinverter to the trunk cable connector until you hear “click”.
C)
If there is any vacant bus port, please plug the AC sub cap on the vacant plug to ensure
waterproof and dustproof.
*Note: Under the circumstances that need to remove the inverter AC cable from bus port, please use the AC connector
unlock tool and insert the tool into the side of AC port.
Step 3. Install AC End Cable
A)
Prepare the AC end cable with the proper length, and insert one side of the cable into the cap.
Match the L, N and Ground line into the slot accordingly. Tighten the screws, and then tighten the cap
back to the port. Plug the upper cover back to the bus connector.
Содержание HM-300NT