1.6. 

FirE iN ThE ChimNEy

When burning wood, sparks from the fireplace may get into  the chimney and ignite the built up 
layer of soot. Therefore, the fireplace insert, smoke flue and the chimney must be regularly cleaned. 
If starting the heating after a long break in operation, then first check that the system is not blocked 
anywhere.

A fire in the chimney is indicated by flames coming from the mouth of the chimney with sparking 
and smoke and with a smell from the fireplace. In this case:

-  

 Call the fire brigade!

-   Close the air supply of the fireplace insert.
-   Remove all flammable items from nearby the chimney.
-    Before the arrival of the fire brigade, do not try to extinguish the fire in the chimney with water. 

In the case of a chimney fire, the temperature can reach up to 1,300 °C. In this case, the water 
will immediately turn into a huge quantity of steam and destroy the chimney.

-   After the fire is gone, contact a chimney sweep who can assess the condition of the chimney.

1.7. 

SuPPly OF COmbuSTiON air

The fireplace insert is technically adapted for the combustion of air supplied from the exterior. 
If during assembly the fireplace insert was not connected to this external air supply, it is necessary 
to ensure a sufficient quantity of combustion air in the room by ventilation. Do not use the fireplace 
insert together with other heating equipment or a consumer appliance that may create under-
pressure in a closed room. Components for controlling the air supply into the fireplace insert must 
not be modified.

1.8. 

uNauThOrizED TEChNiCal mODiFiCaTiONS

It is forbidden to interfere with the construction of fireplace insert. If any unauthorized technical 
modifications are made, the manufacturer will not bear any liability for safety during the operation 
of equipment and the warranty will be automatically invalidated. Only spare parts approved by 
the manufacturer must be used.

2.  FuEl

2.1. 

FOrbiDDEN FuEl

In the fireplace insert it is forbidden to burn any other fuel than that designated for its purpose. 
It is also forbidden to burn liquid fuel and waste. Under no circumstances should petrol, alcohol, 
solvents, etc, be used for ignition! The use of any other fuel than that permitted will damage 
the fireplace insert and load the environment and will also automatically invalidate the warranty.

Содержание ECKA 35

Страница 1: ...User manual Fireplace inserts...

Страница 2: ......

Страница 3: ...which are the result of many years of research and development extensive market experience and intensive contact with customers You have chosen the best quality durability and design which our product...

Страница 4: ...se of fuel 10 3 Description of control elements 11 3 1 Description of control elements 11 3 2 Options for closing the door 12 4 Operation of fireplace inserts 12 4 1 Commissioning burning phase and re...

Страница 5: ...the insert The door handle and glass are hot when in operation there is risk of burning Do not leave children near the fireplace insert unsupervised 1 3 Safe distance In the area where the fire is vi...

Страница 6: ...uring burning so do not touch it Commissioning the heat carrying fireplace insert Before heating check that the following conditions are fulfilled The fireplace insert is connected to the heating syst...

Страница 7: ...r the combustion of air supplied from the exterior If during assembly the fireplace insert was not connected to this external air supply it is necessary to ensure a sufficient quantity of combustion a...

Страница 8: ...lower density soft wood spruce pine poplar fir For regular adding wood with a higher density is recommended hard wood oak beech ash that burns with calm flame and creates a steady heat 2 4 Storage of...

Страница 9: ...rtens its service life In the case of repeated burning of wet wood the insert or parts of the insert can be damaged This will also block the chimney and increase the risk of fire in the soot in the ch...

Страница 10: ...45 51 8 4 15 6 2 5 4 6 ECKA 67 45 51 G 5 6 10 4 1 7 3 2 ECKA 90 40 40 7 7 14 3 2 2 4 2 UKA 37 55 37 57 6 3 11 7 2 0 3 6 UKA 37 75 37 57 7 7 14 3 2 4 4 4 UKA 37 95 37 57 9 1 16 9 2 9 5 2 Hot water fire...

Страница 11: ...doses to the energy demands of your house Fig 4 3 Description of control elements 3 1 Description of control elements Hoxter fire place inserts are produced in two basic versions for opening the door...

Страница 12: ...form your fireplace builder before starting construction 4 Operation of fireplace inserts 4 1 Commissioning burning phase and regulation of air supply First check that there is no large quantity of as...

Страница 13: ...o achieve the optimal output Chapter 2 5 If the burning did not start repeat the step No 4 Fig 8 6 If it is not necessary do not open the door of the fireplace and do not interfere with the burning Le...

Страница 14: ...tdoor temperature In winter when the outdoor temperature is low the chimney has the highest draught level A problem with a sufficient draught may occur in the transient period before and after winter...

Страница 15: ...small amount of clean ash from the burning chamber of the fireplace insert Then wash the glass again with a wet paper cloth and polish with a dry cloth Do not use in any circumstances any aggressive c...

Страница 16: ...ng the whole lengthy Fig 12 Re insert the upper part of the fireplace bed Fig 13 5 4 Regular specialist maintenance Once a year before starting the heating season the fireplace insert should be inspec...

Страница 17: ...s added Possible reasons incorrect fuel is used Chapter 2 2 the draught in the chimney is insufficient in the transient period Chapter 4 3 the door was opened too fast fuel was not added in the correc...

Страница 18: ...replace During operation of the fireplace insert the operator must follow the stated user manual The warranty does not apply to damage originated during transport due to incorrect storage in a wet env...

Страница 19: ...affection of heat mechanical wearing and hardening of sealing Wearing of glass dirtying by soot or remainders of burnt materials colour or other changes by the affection of heat 7 5 Repair and mainte...

Страница 20: ...34 Ku im Czech Republic 420 518 777 701 info hoxter eu www hoxter eu version 04 2015 Changes of the stated data and errors reserved HOXTER gmbh Hersbrucker Stra e 23 91244 Reichenschwand Germany 49 0...

Отзывы: