HIGHTEMPERATURE SENSOR INSTALLATION
Screw the hightemperature sensor on fireplace
insert or stove doors to the designed place.
Minimal lenght for correct measurment
is 20mm / 0.8 in at its end
(H)
.
AIR INLET FLAP INSTALLATION
Connect the air inlet flap by alu pipe with the fireplace insert or stove doors.
The connection between the air inlet flap and the product must be tight enough.
When installing into closed-in build, the air inlet flap must be placed
outside the hightemperature place. The heat resistence of the air inlet
flap is max 50°C / 122°C.
CONTROL UNIT CONNECTION
Connect all the components and power supply adapter with the control unit.
After that plug the power supply adapter to the power feed.
For complete instruction
how to set-up the control
unit follow the instruction
stated in the chapter
„SET-UP“
RUN
SET
S1
TK
T1
12V DC
PWR
1
1
1
2
2
2
min.
20 mm
H